Square D Modbus Solution: Altivar 58 VFD

Size: px
Start display at page:

Download "Square D Modbus Solution: Altivar 58 VFD"

Transcription

1 Point Map November 1, 2004 Systems Integration Square D Modbus Solution: Altivar 58 VFD Table 1. Altivar 58 VFD Point Map, Application LAO Slave Address 1to247 2 LAI Application Number LDI Communication Fault Off/On 4 LAO First IP Address Byte 0 to LAO Second IP Address Byte 0to255 6 LAO Third IP Address Byte 0 to LAO Fourth IP Address Byte 0 to LAO IP Port LAO Base Offset 0to LAO Enable to Send Initial Values 0=No 1=Yes 11 LDO Drive Ready Command Notrdy/Ready 12 LDO Enable Output Voltage Command Disabl/Enable 13 LDO E-Stop Command Stop/Run 14 LDO Enable Command Disabl/Enable 18 LDO Fault Reset (Must Be Set Back to NORMAL by PPCL) Normal/Reset 22 LDO Motor Direction Command Fwd/Rev 23 LDO Motor Run/Stop with Ramp Command On/Off 24 LDO Stop by DC Injection Command Off/On 25 LDO Fast Stop Command Off/On 26 LDO Disable Serial Control Command Off/On 27 LAO Frequency Reference Command Hz 31 LDO External Fault Command Off/On 32 LDO Ramp Switching Command Off/On 41 LDO Drive Controller Locked at Stop Command 42 LDO Disable Timeout Enable/Disable 44 LAO PI Setpoint Command % 45 LAI Frequency Reference Hz Siemens Building Technologies, Inc. Page 1 of 6

2 46 LAI Output Frequency Applied to the Motor Hz 47 LAI Motor Speed Estimated by Controller rpm 48 LAI Motor Current A 49 LAI Line Voltage V 50 LAI Motor Thermal State % 51 LAI Drive Controller Thermal State % 52 LAI Last Fault SeeTable2 53 LDI Power Ready for Startup Notrdy/Ready 54 LDI Drive Controller Ready Notrdy/Ready 55 LDI DRIVECOM Stop/Run 56 LDI Fault Present Off/On 57 LDI Power Present On/Off 58 LDI E-Stop in Progress On/Off 59 LDI Status - Switching Enabled On/Off 60 LDI Alarm Present Normal/Alarm 62 LDI Forced Local Active Off/On 63 LDI Speed Reference Reached Off/On 64 LDI LFRD Reference Exceeded Off/On 67 LDI STOP from Keyboard Off/On 68 LDI Direction of Rotation Fwd/Rev 73 LDI Motor Running Off/On 74 LDI DC Injection Off/On 75 LDI Drive Controller Running in Steady Mode Off/On 76 LDI Thermal Overload Alarm Off/On 77 LDI Ecess Breaking Alarm Off/On 78 LDI Drive Controller Accelerating Off/On 79 LDI Drive Controller Decelerating Off/On 80 LDI Current Limit Alarm Off/On 84 LDI Forward/Reverse Request Off/On 88 LDI High Speed Reached Off/On 89 LDI Speed Reference Reached Off/On 90 LDI Frequency Threshold Reached Off/On 91 LDI Current Threshold Reached Off/On 92 LDI PID Feedback Fault Off/On 93 LDI PID Error Exceeded Off/On Page 2 of 6 Siemens Building Technologies, Inc.

3 117 LAI Past Fault No. 1 SeeTable2 118 LAI Status During Past Fault 1 See Table LAI Past Fault No. 2 SeeTable2 120 LAI Status During Past Fault 2 See Table LAI Past Fault No. 3 SeeTable2 122 LAI Status During Past Fault 3 See Table LAI Past Fault No. 4 SeeTable2 124 LAI Status During Past Fault 4 See Table LAI Past Fault No. 5 SeeTable2 126 LAI Status During Past Fault 5 See Table LAI Past Fault No. 6 SeeTable2 128 LAI Status During Past Fault 6 See Table LAI Past Fault No. 7 SeeTable2 130 LAI Status During Past Fault 7 See Table LAI Past Fault No. 8 SeeTable2 132 LAI Status During Past Fault 8 See Table LDI State of Logic Input 1 Off/On 134 LDI State of Logic Input 2 Off/On 135 LDI State of Logic Input 3 Off/On 136 LDI State of Logic Input 4 Off/On 137 LDI State of Logic Input 5 Off/On 138 LDI State of Logic Input 6 Off/On 141 LDO State of Relay1 Command Relay2 if Enabled Off/On 142 LDO State of Relay2 Command Relay2 if Enabled Off/On 143 LDO State of Logic Output Command of Logic Output if Enabled Off/On 144 LDI State of Red Fault LED Off/On 145 LDI State of Precharge Relay Off/On 146 LDI State of Dynamic Break Transistor Off/On 149 LAI State of Analog input AI1 V 150 LAI State of Analog input AI2 ma 151 LAI State of Analog input AI3 V 152 LAO Image of Analog Output Command Analog Output if Enabled ma 153 LDI Incorrect Calibration Constants Normal/Fail 154 LDI Unknown Drive Controller Rating Normal/Fail 155 LDI Unknown or Incompatible Option Normal/Fail Siemens Building Technologies, Inc. Page 3 of 6

4 156 LDI HD (ASIC) Initialization Incorrect Normal/Fail 157 LDI EEPROM Control Board Fault Normal/Fail 158 LDI EPROM Power Board Fault Normal/Fail 159 LDI Incorrect Configuration Normal/Fail 160 LDI Invalid Configuration Normal/Fail 161 LDI Standard Communication Link Fault Normal/Fail 162 LDI Fast Communication Link Fault Normal/Fail 163 LDI Fast Communication Network Fault Normal/Fail 164 LDI External Fault via Standard Serial Link Normal/Fail 165 LDI External Fault via Fast Serial Link Normal/Fail 166 LDI Motor Short Circuit Fault Normal/Fail 167 LDI Precharge Relay Closure Too Long Normal/Fail 168 LDI Precharge Relay Command Cut-off Normal/Fail 169 LDI Speed Feedback Loss Normal/Fail 170 LDI Overspeed with Speed Feedback Normal/Fail 171 LDI Ramp Not Followed with Speed Feedback Normal/Fail 172 LDI Overcurrent Fault Normal/Fail 173 LDI Loss of Follower Fault Normal/Fail 174 LDI Thermal Sensor Fault Normal/Fail 175 LDI Motor Overheating Fault Normal/Fail 176 LDI Drive Controller Overheating Fault Normal/Fail 177 LDI Motor Overload Fault Normal/Fail 178 LDI Fast Communication Time-out Fault Normal/Fail 179 LDI DC Bus Overvoltage Fault Normal/Fail 180 LDI Input Supply Overvoltage Fault Normal/Fail 181 LDI Motor Phase Loss Fault Normal/Fail 182 LDI Input Supply Phase Loss Fault Normal/Fail 183 LDI Input Supply Undervoltage Fault Normal/Fail 184 LDI Control Board Power Supply Fault Normal/Fail 185 LAI Number of Motor Pole Pairs 187 LAI Motor Torque % 188 LAI Ramp Output Hz 191 LAI Output Power Estimated by the Drive Controller % 192 LAO Analog Output AO1 Value (Only FVC Models) ma Page 4 of 6 Siemens Building Technologies, Inc.

5 193 LAI Voltage Applied to Motor (Only FVC Models) V 194 LAI Drive Power Meter 1 to MWh 195 LAI Total Motor Run Time hrs a Values noted for LDIs and LDOs are in the following format: OFF text/on text. b This column indicates the value/range or engineering units or both if known. c The default English value is not italicized. An italicized entry indicates an SI value. Table 2. Fault Values (Points 52, 117, 119, 121, 123, 125, 129, and 131). Value Description 0 No Fault 1 Internal Fault 2 EEPROM Memory Fault 3 Configuration Parameter Incorrect 4 Configuration Parameter Invalid 5 Standard Communication Link Fault 6 Fast Communication Link Fault 7 Fast Communication Network Fault 8 External Fault 9 Overcurrent Fault 10 Precharge Relay Fault 11 Loss of Speed FB Fault 12 Ramp Not Followed Fault 13 Loss of Follower Fault 14 Thermal Sensor Fault 15 Motor Overheating Fault 16 Drive Controller Overheating Fault 17 Motor Overload Fault 18 DC Bus Overvoltage Fault 19 Input Supply Overvoltage Fault 20 Motor Phase Loss Fault 21 Input Supply Phase Loss Siemens Building Technologies, Inc. Page 5 of 6

6 Table 2. Fault Values (Points 52, 117, 119, 121, 123, 125, 129, and 131). (continued) Value Description 22 Input Supply Undervoltage Fault 23 Motor Short Circuit Fault 24 Overspeed Fault Table 3. Fault Status Values (Points 118, 120, 122, 124, 126, 128, 130, and 132). Value Description Bit 0 Controller Ready Bit 1 E-Stop Not in Progress Bit 2 Switching Disabled Bit 3 Forced Local Inactive Bit 4 Reverse Rotation Bit 5 Motor Running Bit 6 DC Injection Bit 7 Thermal Overload Alarm Bit 8 Excessive Breaking Alarm Bit 9 Drive Accelerating Bit 10 Drive Decelerating Bit 11 Current Limit Alarm Bit 12 Reserved Bit 13 Control via Keypad Bit 14 Control via Fast Serial Link Bit 15 Reverse Requested Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners Siemens Building Technologies, Inc. Siemens Building Technologies, Inc Deerfield Parkway Country of Origin: US Buffalo Grove, IL Page 6 of 6 U.S.A.

LONWORKS Solution to Danfoss Graham VLT 6000 Adjustable Frequency Drive

LONWORKS Solution to Danfoss Graham VLT 6000 Adjustable Frequency Drive Point Map February 23, 2007 Systems Integration LONWORKS Solution to Danfoss Graham VLT 6000 Adjustable Frequency Drive Table 1. VLT 6000 APOGEE Points, Application Number:9098, Program ID:80:00:08:3C:0A:04:04:04.

More information

APOGEE Open Processor with Cummins/Onan Modbus Driver: PowerCommand System

APOGEE Open Processor with Cummins/Onan Modbus Driver: PowerCommand System Point Map April 2, 2004 Systems Integration APOGEE Open Processor with Cummins/Onan Modbus Driver: PowerCommand System This document provides example point maps for common devices in a Cummins/Onan PowerCommand

More information

Siemens Combustion Control Modbus Solution: LMV51

Siemens Combustion Control Modbus Solution: LMV51 Point Map March 11, 2005 Systems Integration Siemens Combustion Control Modbus Solution: LMV51 ForHotWaterBoilers Table 1. LMV51 Burner Controller for Hot Water Boilers Point Map, Application 4642. 1 LAO

More information

McQuay BACnet Solution: Microtech II Applied Rooftop Unit Controller with Discharge Air Control (DAC)

McQuay BACnet Solution: Microtech II Applied Rooftop Unit Controller with Discharge Air Control (DAC) Point Map December 1, 2004 Systems Integration McQuay BACnet Solution: Microtech II Applied Rooftop Unit Controller with Discharge Air Control (DAC) Table 1. Microtech II Series 200 Applied Rooftop Unit

More information

PROGRAMMING GUIDE FOR PPC6000 SERIES

PROGRAMMING GUIDE FOR PPC6000 SERIES NXPG-6001 APRIL 8, 2013 PROGRAMMING GUIDE FOR PPC6000 SERIES DESCRIPTION: This document supplies the commissioning engineer with sufficient information to make appropriate setup and changes to the commissioning

More information

Communications Point Data Base for Serial and Ethernet Communications Protocol DNP3

Communications Point Data Base for Serial and Ethernet Communications Protocol DNP3 Switchgear Technical Data TD280015EN Effective July 2015 Supersedes R280-90-18 8/2012 Communications Point Data Base for Serial and Ethernet Communications Protocol DNP3 For use with Eaton s Cooper Power

More information

Modbus Protocol of Aislu Power Module

Modbus Protocol of Aislu Power Module Modbus Protocol of Aislu Power Module Document Date: 2013/July/03 Version: AD78201.094 Communication Basic: Master as upper computer; Slave as Aislu Power Module 1) Data format: 1 bit start, 8bits data,

More information

maxon motor maxon motor control EPOS Positioning Controller Getting Started Edition July 2007 Positioning Controller Documentation Getting Started

maxon motor maxon motor control EPOS Positioning Controller Getting Started Edition July 2007 Positioning Controller Documentation Getting Started control EPOS Positioning Controller Getting Started Edition July 2007 24/1 Positioning Controller Documentation Getting Started maxon document number 573049-08 EPOS Positioning Controller EPOS 24/1 Getting

More information

Homing with MEI Motion Card and ASIC-100

Homing with MEI Motion Card and ASIC-100 Homing with MEI Motion Card and ASIC-100 This application note explains a correct method of homing one or more axes using MEI motion controller with ASIC-100 software. Homing is a way to establish a reference

More information

MiCOM P443-6/P543-7/P841

MiCOM P443-6/P543-7/P841 MiCOM P443-6/P543-7/P841 Release Notes P443-6/P543-7/P841 Upgrade Platform Hardware Version: M, P Platform Software Version: 75, 65, 45 Publication Reference: P443-6/P543-7/P841-RNC1-TM-EN-1 ALSTOM 2013.

More information

PRC Remedial Action Schemes

PRC Remedial Action Schemes PRC-012-2 Remedial Action Schemes A. Introduction 1. Title: Remedial Action Schemes 2. Number: PRC-012-2 3. Purpose: To ensure that Remedial Action Schemes (RAS) do not introduce unintentional or unacceptable

More information

IEC : Annex F

IEC : Annex F IEC 61511-3:2016 - Annex F SAFETY REQUIREMENT SPECIFICATION Page: Page 2 of 6 CONTENTS 1. SIF SRS... 3 2. SIF SRS(S)... 4 Page: Page 3 of 6 1. SIF SRS Table 1. SRS for the SIS SIS Details Operator Interfaces

More information

EXCERPTS from the SAMS-SPCS SPS Technical Reference

EXCERPTS from the SAMS-SPCS SPS Technical Reference Problem Statement The existing NERC Glossary of Terms definition for a Special Protection System (SPS or, as used in the Western Interconnection, a Remedial Action Scheme or RAS) lacks clarity and specificity

More information

Xantrex GT250 Grid-Tied Photovoltaic Inverter

Xantrex GT250 Grid-Tied Photovoltaic Inverter Xantrex GT250 Grid-Tied Photovoltaic Inverter Xantrex GT250 480 Xantrex GT250 600 Xantrex GT250 480 PG Operation and Maintenance Manual www.schneider-electric.com Xantrex GT250 Grid-Tied Photovoltaic

More information

Requests for information related to this Invitation should be directed to: Justin Pack address:

Requests for information related to this Invitation should be directed to: Justin Pack  address: Boone County, Kentucky INVITATION FOR BID # 101316GC CONVERSION OF EXISTING FIXED SPEED PUMPING SYSTEM TO VARIABLE FREQUENCY DRIVE (VFD) CONTROL PUMPING SYSTEM WITH PIPING MODIFICATIONS FOR LASSING POINTE

More information

QML35. Cover. Voltage A = 5V (+/- 5%) B = 3.3V (+/- 5%)

QML35. Cover. Voltage A = 5V (+/- 5%) B = 3.3V (+/- 5%) QML35 DESIGN FEATURES Bearingless modular design Low profile assembled height Resolutions up to 8192 lines per revolution 4, 6, 8 or 10 pole commutation Easy lock-n-twist assembly feature Through shaft

More information

Standard Development Timeline

Standard Development Timeline PRC 012 2 Remedial Action Schemes Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective.

More information

Xantrex GT100 Grid-Tied Photovoltaic Inverter

Xantrex GT100 Grid-Tied Photovoltaic Inverter Xantrex GT100 Grid-Tied Photovoltaic Inverter Xantrex GT100 208 Xantrex GT100 208 PG Xantrex GT100 480 Xantrex GT100 480 PG Operation and Maintenance Manual www.schneider-electric.com Xantrex GT100 Grid-Tied

More information

Moving PUFs out of the lab

Moving PUFs out of the lab Moving PUFs out of the lab Patrick Schaumont 2/3/2012 Research results by Abhranil Maiti, Jeff Casarona, Luke McHale, Logan McDougall, Vikash Gunreddy, Michael Cantrell What is a Physical Unclonable Function?

More information

Faxed & ed responses are not acceptable - Return bid form in a sealed envelope with the bid number noted on the outside.

Faxed &  ed responses are not acceptable - Return bid form in a sealed envelope with the bid number noted on the outside. 4905 East Broadway, D-232 Bid No. B15/9903 Tucson, AZ 85709-1420 Requisition No. R0054391 Telephone (520) 206-4759 Buyer Philip Quintanilla Date 4/22/15 Page 1 Of 4 Bid must be in this office on or before:

More information

Supersedes: 9/01/11 (Rev.5) Preparer: Owner: Approver: Team Member, North America Process Safety Center of Expertise

Supersedes: 9/01/11 (Rev.5) Preparer: Owner: Approver: Team Member, North America Process Safety Center of Expertise Procedure No.: BC032.019 Page: 1 of 12 Preparer: Owner: Approver: Team Member, North America Process Safety Center of Expertise Manager, North America Process Safety Center of Expertise Sr. Vice President,

More information

Central Texas Electric Cooperative, Inc. Tariff for Electric Service

Central Texas Electric Cooperative, Inc. Tariff for Electric Service 340 Interconnection with Distributed Generation Section 340 of this tariff and all subsections thereof apply to the interconnection and parallel operation of all qualifying (QF) and non-qualifying (NQF)

More information

Accessories and Spare Parts

Accessories and Spare Parts For T Contactors and Contactor Relays Accessories for TB, TC, TF, TG, TK contactors Size Type kg Solid-state compatible auxiliary switch blocks with screw terminals 5TY7 561-1. 14 2 and 4 TF68 For mounting

More information

DS3 System Services Protocol Interim Arrangements

DS3 System Services Protocol Interim Arrangements DS3 System Services Protocol Interim Arrangements DS3 System Services Implementation Project August 2017 Version 2.1 Contents 1 Introduction... 3 2 Governance... 5 3 Compliance Requirements... 6 4 Performance

More information

QM35. Cover. Output. A = Line Driver B = Line Driver (ABZ) /Open Collector (UVW) C = Dual Votage Line Driver (ABZ)/ Open Collector (UVW)

QM35. Cover. Output. A = Line Driver B = Line Driver (ABZ) /Open Collector (UVW) C = Dual Votage Line Driver (ABZ)/ Open Collector (UVW) QM35 DESIGN FEATURES Bearingless modular design Low profile assembled height Resolutions up to 8192 lines per revolution 4, 6, 8 or 10 pole commutation Easy lock-n-twist assembly feature Through shaft

More information

PUF Design - User Interface

PUF Design - User Interface PUF Design - User Interface September 27, 2011 1 Introduction Design an efficient Physical Unclonable Functions (PUF): PUFs are low-cost security primitives required to protect intellectual properties

More information

SPP Reserve Sharing Group Operating Process

SPP Reserve Sharing Group Operating Process SPP Reserve Sharing Group Operating Process Effective: 1/1/2018 1.1 Reserve Sharing Group Purpose In the continuous operation of the electric power network, Operating Capacity is required to meet forecasted

More information

Orange and Rockland Utilities, Inc. Issued in compliance with Order in Case 15-E-0036 dated 07/20/2015.

Orange and Rockland Utilities, Inc. Issued in compliance with Order in Case 15-E-0036 dated 07/20/2015. Orange and Rockland Utilities, Inc. Addendum - SIR-5 INITIAL EFFECTIVE DATE: July 27, 2015 To P.S.C. No. 3 - Electricity Issued in compliance with Order in Case 15-E-0036 dated 07/20/2015. New York State

More information

PMP kW Totem-Pole PFC EVM Test Report

PMP kW Totem-Pole PFC EVM Test Report PMP20873 1kW Totem-Pole PFC EVM Test Report GaN / Next Zhong Ye Oct. 2016 1 Start up High line startup Note: extra 0.9 second was inserted due to DCP010512 bias long startup time. The time can be eliminated

More information

REISSUED JUNE 1, 1988

REISSUED JUNE 1, 1988 REVISED SHEET NO. 29 Effective: October 28, 1966 RULE NO. 14 REISSUED JUNE 1, 1988 Service Connections and Facilities on Customer's Premises A. METER INSTALLATIONS AND MISCELLANEOUS SERVICE EQUIPMENT ON

More information

MICHIGAN ELECTRIC UTILITY

MICHIGAN ELECTRIC UTILITY MICHIGAN ELECTRIC UTILITY Generator Interconnection Requirements Projects with Aggregate Generator Output of 30 kw or More, but Less than 150 kw Effective Aug. 10, 2004 INTRODUCTION This Generator Interconnection

More information

Infineon Reports Record Fiscal Year 2000 and Fourth Quarter Results

Infineon Reports Record Fiscal Year 2000 and Fourth Quarter Results Infineon Reports Record Fiscal Year 2000 and Fourth Quarter Results A record fiscal year 2000: revenues up by 72 percent from last year to Euro 7.28 billion; EBIT up to Euro 1.67 billion; gross margin

More information

Version Updated: December 20, 2017

Version Updated: December 20, 2017 Version 1.05 Updated: December 20, 2017 Copyright 201 Exchange LLC. All rights reserved. This document may not be modified, reproduced, or redistributed without the written permission of IEX Group, Inc.

More information

Distributed Generation Basic Interconnection Requirements and Conditions Effective April 1, 2006

Distributed Generation Basic Interconnection Requirements and Conditions Effective April 1, 2006 Distributed Generation Basic Interconnection Requirements and Conditions Effective April 1, 2006 These rules are intended to outline the requirements for interconnecting a Distributed Generation Facility

More information

Five-Minute Settlements Education

Five-Minute Settlements Education Five-Minute Settlements Education Disclaimer PJM has made all efforts possible to accurately document all information in this presentation. The information seen here does not supersede the PJM Operating

More information

HAZOP AND SAFETY INTEGRITY OVERVIEW

HAZOP AND SAFETY INTEGRITY OVERVIEW HAZOP AND SAFETY INTEGRITY OVERVIEW RJ (Dick) Perry Safety Systems Consultant INTRODUCTION It has been some 15 years since the introduction of the Functional Safety Management standards of IEC 61508 and

More information

PROGRAM DESCRIPTION G4

PROGRAM DESCRIPTION G4 Nobel Weighing Systems Application Software PROGRAM DESCRIPTION G4 Program: G4MI_1.2.102.1 This description is valid for: G4 Weighing Instrument with application program 1.2.102.1 See also the following

More information

COMPARISION OF OFFSHORE REQUIREMENTS

COMPARISION OF OFFSHORE REQUIREMENTS Key to Table COMPARISION OF OFFSHORE REQUIREMENTS (Comparison based on GB Grid Code Issue 4 Revision 13 only and ENSTO - E RFG Internal Version dated 26 June 2012) (Note Does not include other Industry

More information

Frontier Telephone Companies TARIFF FCC NO. 4 Original Page 22-1 ACCESS SERVICE

Frontier Telephone Companies TARIFF FCC NO. 4 Original Page 22-1 ACCESS SERVICE Original Page 22-1 22. Advanced Communications Networks 22.1 TCP/IP Data Aggregation Service (A) Service Description TCP/IP Data Aggregation Service is available in two Modem-Based Dial Up Network Access

More information

FxCraft Trade Manager User Manual (version 1_01)

FxCraft Trade Manager User Manual (version 1_01) FxCraft Trade Manager User Manual (version 1_01) 1 Table of contents FxCraft Trade Manager... 1 User Manual... 1 Introduction... 3 Short description of the product... 4 Installation... 5 Main Window...

More information

Loss Evaluation Considerations for Utility Synchronous Condenser Applications. P.E. MARKEN, A.C. DEPOIAN GE Grid Solutions USA

Loss Evaluation Considerations for Utility Synchronous Condenser Applications. P.E. MARKEN, A.C. DEPOIAN GE Grid Solutions USA 21, rue d Artois, F-75008 PARIS CIGRE US National Committee http : //www.cigre.org 2016 Grid of the Future Symposium Loss Evaluation Considerations for Utility Synchronous Condenser Applications P.E. MARKEN,

More information

COOS-CURRY ELECTRIC COOPERATIVE, INC. RULES AND REGULATIONS. August 24, 2017

COOS-CURRY ELECTRIC COOPERATIVE, INC. RULES AND REGULATIONS. August 24, 2017 POLICY NO. 300-010 COOS-CURRY ELECTRIC COOPERATIVE, INC. RULES AND REGULATIONS August 24, 2017 These are Coos-Curry Electric Cooperative s Rules and Regulations designed to supplement and clarify the application

More information

THERMOPILE DETECTORS FOR MEASUREMENT. TPD 1T 0224, TPD 1T 0524, TPD 1T 0624 General-Purpose Thermopile

THERMOPILE DETECTORS FOR MEASUREMENT. TPD 1T 0224, TPD 1T 0524, TPD 1T 0624 General-Purpose Thermopile THERMOPILE DETECTORS FOR MEASUREMENT THERMOPILE DETECTORS FOR MEASUREMENT TPD 1T 0224, TPD 1T 0524, TPD 1T 0624 General-Purpose Thermopile Applications This is our general-purpose range of thermopile detectors

More information

SHORT-TERM OPERATING RESERVE DESPATCH PROCEDURE STOR DESPATCH PROCEDURE. for Non-Balancing Mechanism Participants

SHORT-TERM OPERATING RESERVE DESPATCH PROCEDURE STOR DESPATCH PROCEDURE. for Non-Balancing Mechanism Participants SHORT-TERM OPERATING RESERVE DESPATCH PROCEDURE STOR DESPATCH PROCEDURE for Non-Balancing Mechanism Participants Version 1.3 reviewed December 2008 ASP1 CONTENTS PART 1 - STOR DESPATCH INTRODUCTION...1

More information

Installation Instructions for Undervoltage Release Mechanism (Cradle Reset) for GB/GHB, GC/GHC Circuit Breakers

Installation Instructions for Undervoltage Release Mechanism (Cradle Reset) for GB/GHB, GC/GHC Circuit Breakers Supersedes IL 15553A Dated 8/10 Contents Description Page Introduction.............................. 2 Installation............................... 3 Effective December 2013 The recommendations and informations

More information

SBI INFRA MANAGEMENT SOLUTIONS PVT LTD (WHOLLY OWNED SUBSIDIARY OF SBI) Bank Street, Koti, Hyderabad

SBI INFRA MANAGEMENT SOLUTIONS PVT LTD (WHOLLY OWNED SUBSIDIARY OF SBI) Bank Street, Koti, Hyderabad SBI INFRA MANAGEMENT SOLUTIONS PVT LTD (WHOLLY OWNED SUBSIDIARY OF SBI) 3 rd Floor, SBI LHO Building, Bank Street, Koti, Hyderabad 500 095 TENDER DOCUMENT FOR DESIGN, MANUFACTURE, SUPPLY, INSTALLATION,

More information

Fixed Income Cash Markets Genium INET Functional Changes. Document Updated:

Fixed Income Cash Markets Genium INET Functional Changes. Document Updated: Fixed Income Cash Markets Genium INET 5.0.0201 Functional Changes Document Updated: 2017-09-14 Contents 1 Introduction 3 2 Manual trade reports on exchange 3 2.1 Manual trade reports 3 2.2 Deferred Trade-Publication

More information

The following Information Requests pertain to the spreadsheet file Attachment_H- 1_Formula_Rate_2015_-Run_1_posted_ _(effective_ ) :

The following Information Requests pertain to the spreadsheet file Attachment_H- 1_Formula_Rate_2015_-Run_1_posted_ _(effective_ ) : TGST 1-1: Refer to PNM S 2014 FERC Form 1 page 207, line 50, Account 353 Station Equipment, please provide a description of significant projects ($5 million or more) contributing to the increase of approximately

More information

FPGA PUF Based on Programmable LUT Delays

FPGA PUF Based on Programmable LUT Delays FPGA PUF Based on Programmable LUT Delays Bilal Habib Kris Gaj Jens-Peter Kaps Cryptographic Engineering Research Group (CERG) http://cryptography.gmu.edu Department of ECE, Volgenau School of Engineering,

More information

07/21/2016 Blackbaud CRM 4.0 Revenue US 2016 Blackbaud, Inc. This publication, or any part thereof, may not be reproduced or transmitted in any form

07/21/2016 Blackbaud CRM 4.0 Revenue US 2016 Blackbaud, Inc. This publication, or any part thereof, may not be reproduced or transmitted in any form Revenue Guide 07/21/2016 Blackbaud CRM 4.0 Revenue US 2016 Blackbaud, Inc. This publication, or any part thereof, may not be reproduced or transmitted in any form or by any means, electronic, or mechanical,

More information

User's Guide 651F LoanMaker Mortgage Calculator

User's Guide 651F LoanMaker Mortgage Calculator User's Guide 651F LoanMaker Mortgage Calculator Table of Contents Qualify Routine - [Qual] Function Key 3 Debt Service Routine [DSR%] Function Key 4 Mortgage Routines - [Pmt], [Mtge] & [Amort] Function

More information

18 STÖGRA panel mount/19 inch-systems series ELK/ELR

18 STÖGRA panel mount/19 inch-systems series ELK/ELR STÖGRA ANTRIEBSTECHNIK GMBH www.stoegra.de stepping motor controls catalogue 0 STÖGRA panel mount/9 inch-systems series ELK/ELR The panel mount / 9 inch rack system series ELK/ELR is a mains ready single

More information

Xantrex XW Power System Xantrex XW / Xantrex XW / Xantrex XW /240 60

Xantrex XW Power System Xantrex XW / Xantrex XW / Xantrex XW /240 60 Xantrex XW Power System Xantrex XW4024 120/240 60 Xantrex XW4548 120/240 60 Xantrex XW6048 120/240 60 Installation Guide www.schneider-electric.com Xantrex XW Power System Installation Guide www.schneider-electric.com

More information

Bitline PUF:! Building Native Challenge-Response PUF Capability into Any SRAM. Daniel E. Holcomb Kevin Fu University of Michigan

Bitline PUF:! Building Native Challenge-Response PUF Capability into Any SRAM. Daniel E. Holcomb Kevin Fu University of Michigan Sept 26, 24 Cryptographic Hardware and Embedded Systems Bitline PUF:! Building Native Challenge-Response PUF Capability into Any SRAM Daniel E. Holcomb Kevin Fu University of Michigan Acknowledgment: This

More information

META TRADER 5 MOBILE (ANDROID)

META TRADER 5 MOBILE (ANDROID) META TRADER 5 MOBILE (ANDROID) USER GUIDE www.fxbtrading.com 1 CONTENTS Getting Started...3 Quotes...4 Depth of Market...8 Chart...8 Trade...10 Type of orders...13 Market execution...16 History...19 Accounts...20

More information

Interconnection Process for Customer-Owned Generation (QFs)

Interconnection Process for Customer-Owned Generation (QFs) Interconnection Process for Customer-Owned Generation (QFs) Member-consumer makes Co-op letter explaining process & providing information (including co-op Application Member reviews information Member

More information

Getting started. UltraBranch Business Edition. alaskausa.org

Getting started. UltraBranch Business Edition. alaskausa.org Getting started UltraBranch Business Edition alaskausa.org Contents 2 4 6 8 9 11 13 14 15 21 22 23 24 Key features Getting started Company permissions Setting & exceeding limits Configuring ACH & tax payments

More information

AUFLS information paper

AUFLS information paper AUFLS information paper Contents 1 Introduction... 1 2 The under-frequency management challenge... 1 3 Overview of current arrangements... 3 3.1 The current AUFLS exemptions... 4 4 Initiatives to address

More information

Authority 1: EAC (Electricity Authority of Cyprus) as acting DSO, Technical Instruction KE1/33/2005

Authority 1: EAC (Electricity Authority of Cyprus) as acting DSO, Technical Instruction KE1/33/2005 A. INTERCONNECTION RULES Country: CYPRUS Eligible renewable /other technologies: PV Applicable sectors: All sectors Breakpoint for Small System (Simplified Rules): 20 kw Rules for net metering systems:

More information

MS330-2 MULTISTRIPPER Operating Manual

MS330-2 MULTISTRIPPER Operating Manual MULTISTRIPPER This manual is provided to persons purchasing an SPE machine and may not be reproduced in part or full without written permission of SPE International Ltd. This manual provides the basic

More information

How to prepare an order in Worksheet

How to prepare an order in Worksheet The following pages are a walk through of a basic way to get an order prepared with worksheet for AIS. This is only a guide to help you learn the best way to get an order together, and how to create an

More information

Equivalence between Masterpact M and the new range NT/NW

Equivalence between Masterpact M and the new range NT/NW Substitution guide Equivalence between Masterpact M and the new range NT/NW Masterpact substitution guide-03/00-dbtp204en Masterpact M 08-63 Substitution by frame size 08-10 - 12-16 - 20-25 - 32 40 50

More information

Programmable AC & DC Electronic Load

Programmable AC & DC Electronic Load INVITATION FOR TENDER FOR SUPPLY OF EQUIPMENT Sealed tender offers are invited in two separate sealed covers (Technical and Commercial offers) from eligible manufacturers/suppliers or their direct Indian

More information

3.6V / 2600mAh Primary Lithium x 0.85 (60mm x 21mm) 1.0 oz (28 gr) -30 C to +77 C. Bluetooth Low Energy dBm. +5dBm. 1Mbit/s / 2Mbit/s*

3.6V / 2600mAh Primary Lithium x 0.85 (60mm x 21mm) 1.0 oz (28 gr) -30 C to +77 C. Bluetooth Low Energy dBm. +5dBm. 1Mbit/s / 2Mbit/s* SPECIFICATION SHEET BEEKs Industrial VER 1.6 HARDWARE SPECIFICATION Battery Size Weight Temperature Range Bluetooth Type Bluetooth Sensitivity Bluetooth Max Power Output Bluetooth Antenna Frequency Supported

More information

T-D Interconnections: Best Value Planning White Paper January 2016

T-D Interconnections: Best Value Planning White Paper January 2016 T-D Interconnections: Best Value Planning White Paper Updated January 2016 1. Purpose This paper defines the process and criteria that together constitute joint best value planning (BVP) between ATC and

More information

INVITATION FOR TENDER FOR SUPPLY OF EQUIPMENT

INVITATION FOR TENDER FOR SUPPLY OF EQUIPMENT INVITATION FOR TENDER FOR SUPPLY OF EQUIPMENT Sealed tender offers are invited in two separate sealed covers (Technical and Commercial offers) from eligible manufacturers/suppliers or their direct Indian

More information

TB General description. 2. Features and benefits. 3. Applications. 4. Pinning information. 5. Ordering information

TB General description. 2. Features and benefits. 3. Applications. 4. Pinning information. 5. Ordering information 30 September 2016 Product data sheet 1. General description High voltage, high speed, planar passivated NPN power switching transistor in a SOT54 (TO92) plastic package intended for use in low power SMPS

More information

PMBFJ111; PMBFJ112; PMBFJ113

PMBFJ111; PMBFJ112; PMBFJ113 SOT23 PMBFJ111; PMBFJ112; PMBFJ113 Rev. 4 20 September 2011 Product data sheet 1. Product profile 1.1 General description Symmetrical in a SOT23 package. 1.2 Features and benefits High-speed switching

More information

Debitek Cash Register Debit Card Terminal For Sharp 3310 Enhanced Registers Installation and Operation Manual

Debitek Cash Register Debit Card Terminal For Sharp 3310 Enhanced Registers Installation and Operation Manual Page 1 of 12 Debitek Cash Register Debit Card Terminal For Sharp 3310 Enhanced Registers Installation and Operation Manual Table of Contents Operating Instructions No Card Message Card Balance Too Low

More information

500 W bis 1,500 W 60 V bis 400 V 5 A bis 150 A. Electronic Load PL

500 W bis 1,500 W 60 V bis 400 V 5 A bis 150 A. Electronic Load PL 500 W bis 1,500 W 60 V bis 400 V 5 A bis 150 A Electronic Load PL We support you from the first contact Until delivery of your product GTC Application Notes SE Accessories NL ZSAC PMLA PMLI ERI ZSLV ZSLC

More information

TRIP OF MULTIPLE TRANSMISSION ELEMENTS IN THE SOUTHERN NSW AREA, 11 FEBRUARY 2017

TRIP OF MULTIPLE TRANSMISSION ELEMENTS IN THE SOUTHERN NSW AREA, 11 FEBRUARY 2017 TRIP OF MULTIPLE TRANSMISSION ELEMENTS IN THE SOUTHERN NSW AREA, 11 FEBRUARY 2017 REVIEWABLE OPERATING INCIDENT REPORT UNDER THE NATIONAL ELECTRICITY RULES Published: 15 September 2017 INCIDENT CLASSIFICATIONS

More information

TRI-COUNTY ELECTRIC COOPERATIVE APPLICATION AND AGREEMENT FOR INTERCONNECTION AND NET METERING OF SYSTEMS WITH CAPACITY OF 100 kw OR LESS

TRI-COUNTY ELECTRIC COOPERATIVE APPLICATION AND AGREEMENT FOR INTERCONNECTION AND NET METERING OF SYSTEMS WITH CAPACITY OF 100 kw OR LESS TRI-COUNTY ELECTRIC COOPERATIVE APPLICATION AND AGREEMENT FOR INTERCONNECTION AND NET METERING OF SYSTEMS WITH CAPACITY OF 100 kw OR LESS PROCEDURES: I. Members Applying for New Interconnection/Submission

More information

PrimeTrade FX User Guide

PrimeTrade FX User Guide Global Markets 3Q 2018 PrimeTrade FX For Institutional Clients only. This material does not constitute as investment research. For the full legal disclaimer, please refer to the end of this document. Getting

More information

ATTACHMENT G SMALL GENERATOR INTERCONNECTION PROCEDURES (SGIP) (For Generating Facilities No Larger Than 20 MW)

ATTACHMENT G SMALL GENERATOR INTERCONNECTION PROCEDURES (SGIP) (For Generating Facilities No Larger Than 20 MW) ATTACHMENT G SMALL GENERATOR INTERCONNECTION PROCEDURES (SGIP) (For Generating Facilities No Larger Than 20 MW) TABLE OF CONTENTS Page No. Section 1. Application... 1.1 Applicability... 1.2 Pre-Application...

More information

DaVinci Resolve 9 Menus & Keyboard Shortcuts

DaVinci Resolve 9 Menus & Keyboard Shortcuts DaVinci Resolve 9 Menus & Keyboard Shortcuts Shortcut descriptions are for Mac OS X. Windows and Linux use Control instead of Command and Alt instead of Option. Menu Resolve 9 Resolve 8 DaVinci Resolve

More information

18/02/2014. IRIS PAYE-Master. Release Notes

18/02/2014. IRIS PAYE-Master. Release Notes 18/02/2014 IRIS PAYE-Master Release Notes 16/02/2015 Dear Customer, Welcome to your IRIS PAYE-Master software update for 2014/2015. This update of the software includes some new features and enhancements.

More information

Oracle Banking Platform

Oracle Banking Platform Oracle Banking Platform Functional Upgrade Guide Release 2.6.0.0.0 E87094-01 May 2017 Oracle Banking Platform Functional Upgrade Guide, Release 2.6.0.0.0 E87094-01 Copyright 2011, 2017, Oracle and/or its

More information

Operafone Executive User Guide. Operafone Executive User Guide

Operafone Executive User Guide. Operafone Executive User Guide Operafone Executive User Guide Operafone Executive User Guide 1 Specifications are subject to change without notice. Facilities described may or may not be supported by your network. Operafone Executive

More information

UNITED STATES SECURITIES AND EXCHANGE COMMISSION Washington, D.C FORM 10-K. Commission File Number:

UNITED STATES SECURITIES AND EXCHANGE COMMISSION Washington, D.C FORM 10-K. Commission File Number: UNITED STATES SECURITIES AND EXCHANGE COMMISSION Washington, D.C. 20549 (Mark One) FORM 10-K x Annual report pursuant to Section 13 or 15(d) of the Securities Exchange Act of 1934 For the fiscal year ended

More information

Multiple Accelerometers Inline calibration

Multiple Accelerometers Inline calibration Application note Multiple Accelerometers Inline calibration Document revision 1.0 Document release date 02 December 2013 Document number BST-MAS-AN030-00 Technical reference code(s) Notes 0 273 141 122

More information

A DRAM based Physical Unclonable Function Capable of Generating >10 32 Challenge Response Pairs per 1Kbit Array for Secure Chip Authentication

A DRAM based Physical Unclonable Function Capable of Generating >10 32 Challenge Response Pairs per 1Kbit Array for Secure Chip Authentication A DRAM based Physical Unclonable Function Capable of Generating >10 32 Challenge Response Pairs per 1Kbit Array for Secure Chip Authentication Q. Tang, C. Zhou, *W. Choi, *G. Kang, *J. Park, K. K. Parhi,

More information

TITLE: Line Current Differential Relay PHONE NO: (573) ISSUE DATE:

TITLE: Line Current Differential Relay PHONE NO: (573) ISSUE DATE: BID REQUEST NO.: 19 8001 KS C STRATEGIC SOURCING SPECIALIST: Kevin Summers TITLE: Line Current Differential Relay PHONE NO: (573) 884-8797 ISSUE DATE: 7-23-18 E-MAIL: SummersK@umsystem.edu RETURN BID NO

More information

I. Members Applying for New Interconnection/Submission of Plans/Specifications.

I. Members Applying for New Interconnection/Submission of Plans/Specifications. PLATTE-CLAY ELECTRIC COOPERATIVE APPLICATION AND AGREEMENT FOR INTERCONNECTION AND NET METERING OF RENEWABLE ENERGY SYSTEMS WITH CAPACITY OF 100 kw OR LESS PROCEDURES: I. Members Applying for New Interconnection/Submission

More information

Chapter 1: Data Storage

Chapter 1: Data Storage Chapter 1: Data Storage Computer Science: An Overview Tenth Edition by J. Glenn Brookshear Copyright 2008 Pearson Education, Inc. Publishing as Pearson Addison-Wesley Chapter 1: Data Storage 1.1 Bits and

More information

Comprehensive solutions for urinalysis

Comprehensive solutions for urinalysis Comprehensive solutions for urinalysis Our McKesson Urine Analyzer Controls and Reagent Test Strips are designed to meet your needs for fast, reliable results. Designed for use at the point of care, our

More information

Development of ATO System for Korea Standardized EMU

Development of ATO System for Korea Standardized EMU Development of ATO System for Korea Standardized EMU Tae-ki Ahn, Seong-ho Han, Su-gil Lee, Jong-duk Chung, Won-kyong Kim Urban Transit System Team Urban Transit Engineering Department Korea Railroad Research

More information

Implementation Plan Project PRC-005 FERC Order No. 803 Directive PRC-005-6

Implementation Plan Project PRC-005 FERC Order No. 803 Directive PRC-005-6 Project 2007-17.4 PRC-005 FERC Order No. 803 Directive PRC-005-6 Standards Involved Approval: PRC 005 6 Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance Retirement: PRC

More information

SAFETY COMMAND DEVICES

SAFETY COMMAND DEVICES AFY COMMAND DVIC 00 -top ope witch he 00 -top ope witch series is used with preference with expansive points of operation. Its simple operation ensures fast stop command output along the point of operation.

More information

New York State Public Service Commission

New York State Public Service Commission PSC NO. 220 ELECTRICITY ADDENDUM TYPES: SIR NIAGARA MOHAWK POWER CORPORATION ADDENDUM NO. 7 INITIAL EFFECTIVE DATE: AUGUST 16, 2017 STAMPS: ISSUED IN COMPLIANCE WITH ORDER IN CASE 16-E-0560 Issued August

More information

NPCC Regional Reliability Reference Directory # 5 Reserve

NPCC Regional Reliability Reference Directory # 5 Reserve NPCC Regional Reliability Reference Directory # 5 Task Force on Coordination of Operations Revision Review Record: December 2 nd, 2010 October 11 th, 2012 Adopted by the Members of the Northeast Power

More information

INVITATION FOR QUOTATION. TEQIP-III/2018/uiet/Shopping/72

INVITATION FOR QUOTATION. TEQIP-III/2018/uiet/Shopping/72 INVITATION FOR QUOTATION TEQIP-III/2018/uiet/Shopping/72 08-Feb-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the

More information

06/13/2017 Blackbaud Altru 4.96 Revenue US 2017 Blackbaud, Inc. This publication, or any part thereof, may not be reproduced or transmitted in any

06/13/2017 Blackbaud Altru 4.96 Revenue US 2017 Blackbaud, Inc. This publication, or any part thereof, may not be reproduced or transmitted in any Revenue Guide 06/13/2017 Blackbaud Altru 4.96 Revenue US 2017 Blackbaud, Inc. This publication, or any part thereof, may not be reproduced or transmitted in any form or by any means, electronic, or mechanical,

More information

Version Overview

Version Overview O*U*C*H Version 4.1 Updated July 18, 2016 1 Overview... 1 1.1 Architecture... 2 1.2 Data Types... 2 1.3 Fault Redundancy... 2 1.4 Service Bureau Configuration... 3 2 Inbound Messages... 3 2.1 Enter Order

More information

Automotive Wireless External Mirror Control - Test Data

Automotive Wireless External Mirror Control - Test Data Automotive Wireless External Mirror Control - Test Data This document shares the tests results of the TIDA00357 with a TYC Automotive Rear View Mirror. The data is structured into two main categories:

More information

www.unique-project.eu Exchange of security-critical data Computing Device generates, stores and processes security-critical information Computing Device 2 However: Cryptographic secrets can be leaked by

More information

Standard Development Timeline

Standard Development Timeline Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Description of Current Draft

More information

New York State Public Service Commission

New York State Public Service Commission PSC NO. 220 ELECTRICITY ADDENDUM TYPES: SIR NIAGARA MOHAWK POWER CORPORATION ADDENDUM NO. 9 INITIAL EFFECTIVE DATE: NOVEMBER 2, 2018 STAMPS: ISSUED IN COMPLIANCE WITH ORDER IN CASE 18-E-0018 Issued October

More information

Q Financial Results. April 27, 2011

Q Financial Results. April 27, 2011 Q1 2011 Financial Results April 27, 2011 2 Q111 Highlights Net revenues of $2,535 million Up 9.0% year-over-year and down 10.5% sequentially Driven by solid demand in Automotive applications and Analog,

More information

MIRROR TRADER PLATFORM FREQUENTLY ASKED QUESTIONS

MIRROR TRADER PLATFORM FREQUENTLY ASKED QUESTIONS MIRROR TRADER PLATFORM FREQUENTLY ASKED QUESTIONS Page 1 FAQ Contents Questions Regarding Semi Automatic Mirroring Questions Regarding Manual Trading Questions Regarding The Automatic Mirroring General

More information

Design PMP40133 Test Results

Design PMP40133 Test Results Test Report Nov 2016 Design PMP40133 Test Results 1 GENERAL 1.1 PURPOSE The PMP40133 control board provides the interface with fast charger adapter solution. The main MCU use MSP430G2955 which is in charge

More information