WSPP Operating Committee BAL 002 Update. Kenneth W. Otto, PE March 7, 2014

Size: px
Start display at page:

Download "WSPP Operating Committee BAL 002 Update. Kenneth W. Otto, PE March 7, 2014"

Transcription

1 WSPP Operating Committee BAL 002 Update Kenneth W. Otto, PE March 7, 2014

2 Disclaimer This presentation is for informational purposes and should not be construed as, and does not constitute legal advice. Participants should seek their own legal counsel to make their own legal determination regarding the subject matter discussed herein.

3 The Basics First we need to understand: NERC BAL-001 NERC BAL-002

4 NERC BAL-001 Title: Real Power Balancing Control Performance Purpose: To maintain Interconnect steadystate frequency within defined limits by balancing real power demand and supply in real-time.

5 NERC BAL-002 Title: Disturbance Control Performance Purpose: The purpose of the Disturbance Control Standard (DCS) is to ensure the Balancing Authority is able to utilize its Contingency Reserve to balance resources and demand and return Interconnection frequency within defined limits following a Reportable Disturbance.

6 NERC BAL-002 cont. Because generator failures are far more common than significant losses of load and because Contingency Reserve activation does not typically apply to the loss of load, the application of DCS is limited to the loss of supply and does not apply to the loss of load.

7 The BAL-002-WECC-2 Standard Purpose: To specify the quantity and types of Contingency Reserve required to ensure reliability under normal and abnormal conditions. Requires an RSG or BA to carry a sufficient quantity of reserve to restore balance following the most severe single contingency that may occur within the RSG/BA s area of responsibility

8 What the Standard Is Defines the quantity and quality of Contingency Reserves required to be held in the WECC Clearly defines who is responsible for carrying these reserves. Balancing Authorities unless the BA is a member of a Reserve Sharing Group (RSG) Reserve Sharing Group

9 What the Standard Is Not It is not a Frequency Response Standard It is not a prescription on how or when to respond to a contingency It is not a Regulating Reserve standard It is not intended to firm up energy sales

10 What the Standard Is Not It is not intended to firm up energy sales

11 Firm Sales A seller of Firm energy under Schedule C Has an obligation to back up the sale in the event the primary source of generation is lost. May carry its own back-up generating resources May contract with a third party for back-up generating resources

12 Reserve Sharing Groups A Firm sale may be backed by a Reserve Sharing Group (for a short period, generally one hour) If the seller is a member of a Reserve Sharing Group and If the seller s generator is covered by the Reserve Sharing Group If the loss of said generator meets the Reserve Sharing Group s criteria for initiating a response Keeping in mind that a Reserve Sharing Group s primary interest is to restore balance of supply and demand within its footprint.

13 BAs A Firm sale may be backed indirectly by a BA (for a short period, generally one hour) If the seller s generator resides in the BA If the loss of said generator causes an imbalance of supply and demand within the BA s footprint and is severe enough to warrant a reserve response. Keeping in mind that a BA s primary interest is to restore balance of supply and demand within its footprint in order to continue to serve the loads within its boundaries.

14 BAs and RSGs Have no obligation to back your sales Are obligated to balancing supply and demand within their boundaries for the purpose of reliably operating the system Can and do curtail schedules to restore energy balance Deploy reserves for reliability purposes, not to support the market efforts of PSEs

15 Sellers Must ensure that they are fully cognizant of their relationship with both BAs and RSGs. Know your Reserve Groups by-laws and operating policies Know your interconnection agreement with your BA Understand your BA s tariff

16 Sellers Know under what conditions your loss of resource will be backed by a third party Determine what additional generating reserves you might choose to have available to back your Firm sales.

17 Buyers Know your seller Know the path of delivery Know your risk of losing an energy import Purchase according to your level of comfort

18 Changes to BAL-002-WECC-2 No longer assigns load responsibility to an energy transaction Energy transactions no longer change the amount of reserves an RSG or BA are required to carry under the Standard Removes the RSG/BA s reliance on the firmness of energy market transactions to restore supply/demand balance

19 Requirement R1 R1 minimum amount of Contingency Reserves is the greater of Most Severe Single Contingency or 3 Percent of Load plus 3 Percent of Generation

20 Requirement R2 R2 minimum Operating Reserve Spinning equal to 50 percent of R1 Must be immediately and automatically responsive to frequency Must be fully responsive within 10 minutes While Operating Reserve Spinning must be initially responsive to frequency, R2 does not require a full automatic response via governor action. Initial response only.

21 Requirement R3 R3 requirement for additional reserves if the Sink BA is buying energy associated with the Source BA s Contingency Reserves For example, purchase of energy that is recallable by the Source BA for reserve activation. Tagged as Product Code C-RE: Capacity associated with energy recallable for reserves. This product is energy which is recallable within ten minutes of activation of reserves and has been included in the Source Balancing Authorities reserve resources.

22 Requirement R4 R4 requirement for additional reserve at the Source BA if they have sold Contingency Reserves which can be called upon by the Buyer. C-SP: Capacity for spinning reserve. On-Demand spinning reserve obligation/resource is a spinning reserve product that can be activated through the adjustment of a capacity e-tag. C-NS: Capacity for non-spinning reserve. On-Demand nonspinning reserve obligation/resource is a non-spinning reserve product that can be activated through the adjustment of a capacity e-tag.

23 BAL-002-WECC-2 Contingency Reserve Guidance Document For further clarification: Western Electricity Coordinating Council > Library > Documentation Categorization Files > Regional Standards > BAL-002-WECC-2 Contingency Reserve Guidance Document

24 WSPP Agreement References Schedule C C 3.9 Seller shall be responsible for ensuring that Service Schedule C transactions are scheduled as firm power consistent with the most recent rules adopted by the applicable NERC regional reliability council.

25 WSPP Agreement References Schedule A A 3.8 Unless otherwise agreed, the Purchaser shall be responsible for maintaining operating reserve requirements as back up for Economy Energy Service purchased and the Seller shall not be required to maintain such operating reserve.

26 Need to change? Refers to operating reserve requirements as back up for Economy Energy Service purchased. Is such a requirement still valid?

27 QUESTIONS?

3. Purpose: To specify the quantity and types of Contingency Reserve required to ensure reliability under normal and abnormal conditions.

3. Purpose: To specify the quantity and types of Contingency Reserve required to ensure reliability under normal and abnormal conditions. WECC Standard BAL-002-WECC-2 A. Introduction 1. Title: 2. Number: BAL-002-WECC-2 3. Purpose: To specify the quantity and types of required to ensure reliability under normal and abnormal conditions. 4.

More information

SPP Reserve Sharing Group Operating Process

SPP Reserve Sharing Group Operating Process SPP Reserve Sharing Group Operating Process Effective: 1/1/2018 1.1 Reserve Sharing Group Purpose In the continuous operation of the electric power network, Operating Capacity is required to meet forecasted

More information

3. Purpose: To specify the quantity and types of Contingency Reserve required to ensure reliability under normal and abnormal conditions.

3. Purpose: To specify the quantity and types of Contingency Reserve required to ensure reliability under normal and abnormal conditions. WECC Standard BAL-002-WECC-2a A. Introduction 1. Title: 2. Number: BAL-002-WECC-2a 3. Purpose: To specify the quantity and types of required to ensure reliability under normal and abnormal conditions.

More information

ReliabilityFirst Regional Criteria 1. Operating Reserves

ReliabilityFirst Regional Criteria 1. Operating Reserves ReliabilityFirst Regional Criteria 1 Operating Reserves 1 A ReliabilityFirst Board of Directors approved good utility practice document which are not reliability standards. ReliabilityFirst Regional Criteria

More information

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION ) ) )

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION ) ) ) UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION North American Electric Reliability Corporation ) ) ) Docket No. RM13-13-000 INFORMATIONAL FILING OF THE NORTH AMERICAN ELECTRIC

More information

Standard BAL Disturbance Control Performance

Standard BAL Disturbance Control Performance A. Introduction 1. Title: Disturbance Control Performance 2. Number: BAL-002-0 3. Purpose: The purpose of the Disturbance Control Standard (DCS) is to ensure the Balancing Authority is able to utilize

More information

Implementation of BAL Dede Subakti

Implementation of BAL Dede Subakti Implementation of BAL-002-2 Dede Subakti Agenda Background information Impact assessment Issue statement Implementation options Request for comments Page 2 Background Information NERC BAL-002-2 was approved

More information

Welcome! Our goal: Liquidity, Liquidity, Liquidity

Welcome! Our goal: Liquidity, Liquidity, Liquidity Welcome! Welcome! Our goal: Liquidity, Liquidity, Liquidity Welcome! Our goal: Liquidity, Liquidity, Liquidity For that, we need clarity and agreement on the definition of what products we re trading.

More information

BAL-002-2(i) Disturbance Control Standard Contingency Reserve for Recovery from a Balancing Contingency Event

BAL-002-2(i) Disturbance Control Standard Contingency Reserve for Recovery from a Balancing Contingency Event Balancing A. Introduction 1. Title: Disturbance Control Standard Contingency Reserve for Recovery from a Balancing 2. Number: BAL-002-2(i) 3. Purpose: To ensure the Balancing Authority or Reserve Sharing

More information

Standard BAL Disturbance Control Performance

Standard BAL Disturbance Control Performance Introduction 1. Title: Disturbance Control Performance 2. Number: BAL-002-0 3. Purpose: The purpose of the Disturbance Control Standard (DCS) is to ensure the Balancing Authority is able to utilize its

More information

Contingency Reserve Cost Allocation. Draft Final Proposal

Contingency Reserve Cost Allocation. Draft Final Proposal Contingency Reserve Cost Allocation Draft Final Proposal May 27, 2014 Contingency Reserve Cost Allocation Draft Final Proposal Table of Contents 1 Introduction... 3 2 Changes to Straw Proposal... 3 3 Plan

More information

WECC Standard BAL-STD Operating Reserves

WECC Standard BAL-STD Operating Reserves A. Introduction 1. Title: Operating Reserves 2. Number: BAL-STD-002-0 3. Purpose: Regional Reliability Standard to address the Operating Reserve requirements of the Western Interconnection. 4. Applicability

More information

Eastern Interconnection Balancing Authority Webinar. NERC Resources Subcommittee August 15, 2017

Eastern Interconnection Balancing Authority Webinar. NERC Resources Subcommittee August 15, 2017 Eastern Interconnection Balancing Authority Webinar NERC Resources Subcommittee August 15, 2017 Agenda Overview of Time and Inadvertent management upon BAL-004 retirement EI BA survey responses Options

More information

WECC Standard BAL-STD Operating Reserves

WECC Standard BAL-STD Operating Reserves A. Introduction 1. Title: Operating Reserves 2. Number: BAL-STD-002-0 3. Purpose: Regional Reliability Standard to address the Operating Reserve requirements of the Western Interconnection. 4. Applicability

More information

BAL Background Document. August 2014

BAL Background Document. August 2014 BAL-002-2 Background Document August 2014 1 Table of Contents Introduction... 3 Rationale by Requirement... 78 Requirement 1... 78 Requirement 2... 1112 2 Introduction The revision to NERC Policy Standards

More information

145 FERC 61,141 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION. 18 CFR Part 40. [Docket No. RM ; Order No.

145 FERC 61,141 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION. 18 CFR Part 40. [Docket No. RM ; Order No. 145 FERC 61,141 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION 18 CFR Part 40 [Docket No. RM13-13-000; Order No. 789] Regional Reliability Standard BAL-002-WECC-2 Contingency Reserve (Issued

More information

August 17, 2017 VIA ELECTRONIC FILING. Veronique Dubois Régie de l'énergie Tour de la Bourse 800, Place Victoria Bureau 255 Montréal, Québec H4Z 1A2

August 17, 2017 VIA ELECTRONIC FILING. Veronique Dubois Régie de l'énergie Tour de la Bourse 800, Place Victoria Bureau 255 Montréal, Québec H4Z 1A2 !! August 17, 2017 VIA ELECTRONIC FILING Veronique Dubois Régie de l'énergie Tour de la Bourse 800, Place Victoria Bureau 255 Montréal, Québec H4Z 1A2 Re: Revisions to the Violation Risk Factors for Reliability

More information

BAL Disturbance Control Performance - Contingency Reserve for Recovery from a Balancing Contingency Event Standard Background Document

BAL Disturbance Control Performance - Contingency Reserve for Recovery from a Balancing Contingency Event Standard Background Document BAL-002-2 Disturbance Control Performance - Contingency Reserve for Recovery from a Balancing Contingency Event Standard Background Document 3353 Peachtree Road NE Suite 600, North Tower Atlanta, GA 30326

More information

Reliability Guideline: Operating Reserve Management

Reliability Guideline: Operating Reserve Management Reliability Guideline: Operating Reserve Management Preamble: It is in the public interest for NERC to develop guidelines that are useful for maintaining or enhancing the reliability of the Bulk Electric

More information

NPCC Regional Reliability Reference Directory # 5 Reserve

NPCC Regional Reliability Reference Directory # 5 Reserve NPCC Regional Reliability Reference Directory # 5 Task Force on Coordination of Operations Revision Review Record: December 2 nd, 2010 October 11 th, 2012 Adopted by the Members of the Northeast Power

More information

Peak Reliability SUMMARY DOCUMENT FOR STAKEHOLDER COMMENT. ECC Final State Design. Jeremy West. Manager, Interconnection Reliability Initiatives

Peak Reliability SUMMARY DOCUMENT FOR STAKEHOLDER COMMENT. ECC Final State Design. Jeremy West. Manager, Interconnection Reliability Initiatives Peak Reliability SUMMARY DOCUMENT FOR STAKEHOLDER COMMENT ECC Final State Design Jeremy West Manager, Interconnection Reliability Initiatives November 22, 2017 Vancouver, Washington Loveland, Colorado

More information

BC HYDRO REAL TIME OPERATIONS OPERATING ORDER 1T 61

BC HYDRO REAL TIME OPERATIONS OPERATING ORDER 1T 61 BC HYDRO REAL TIME OPERATIONS OPERATING ORDER 1T 61 BC HYDRO OPERATING RESERVE AND NWPP RESERVE SHARING PROCEDURES Supersedes 1T-61 issued 26 September 2011 Review Year: 2018 Original signed by Brett Hallborg

More information

Procedure for ERO Support of Frequency Response and Frequency Bias Setting Standard

Procedure for ERO Support of Frequency Response and Frequency Bias Setting Standard Procedure for ERO Support of Frequency Response and Frequency Bias Setting Standard NERC Report Title Report Date I Table of Contents Preface... iii Introduction...iiv Chapter 1: Event Selection Process...

More information

Frequency Response Straw Proposal Stakeholder Meeting

Frequency Response Straw Proposal Stakeholder Meeting Frequency Response Straw Proposal Stakeholder Meeting October 19, 2015 October 19, 2015 stakeholder meeting agenda Time Topic Presenter 1:00-1:05 Introduction Kim Perez 1:05-1:10 Updated schedule Kim Perez

More information

BAL Frequency Response & Frequency Bias Setting Standard

BAL Frequency Response & Frequency Bias Setting Standard Attachment A BAL 003 1 Frequency Response & Frequency Bias Setting Standard Background This document outlines the ERO process for supporting the Frequency Response Standard (FRS). Event Selection Criteria

More information

Background Information:

Background Information: Project 2010-14.1 Balancing Authority Reliability-based Control BAL-002-2 Disturbance Control Performance - Contingency Reserve for Recovery from a Balancing Contingency Event Please do not use this form

More information

Standard Development Timeline

Standard Development Timeline Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Description of Current Draft

More information

California Independent System Operator Corporation

California Independent System Operator Corporation California Independent System Operator Corporation Request for Proposal Transferred Frequency Response Submittal Deadlines: Friday September 30, 2016 Time: 11:59pm Pacific Daylight Time Submit Proposals

More information

ISO Tariff Original Sheet No. 637 ISO TARIFF APPENDIX L. Rate Schedules

ISO Tariff Original Sheet No. 637 ISO TARIFF APPENDIX L. Rate Schedules Original Sheet No. 637 ISO TARIFF APPENDIX L Rate Schedules Original Sheet No. 638 Schedule 1 Grid Management Charge The Grid Management Charge (ISO Tariff Section 8.0) is a formula rate designed to recover

More information

NORMES DE FIABILITÉ DE LA NERC - BAL (VERSION ANGLAISE)

NORMES DE FIABILITÉ DE LA NERC - BAL (VERSION ANGLAISE) COORDONNATEUR DE LA FIABILITÉ Direction Contrôle des mouvements d énergie Demande R-3699-2009 NORMES DE FIABILITÉ DE LA NERC - BAL (VERSION ANGLAISE) Original : 2013-03-27 HQCMÉ-8, Document 2.4 Révisé

More information

December 23, By etariff Filing Hon. Kimberly D. Bose, Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, DC 20426

December 23, By etariff Filing Hon. Kimberly D. Bose, Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, DC 20426 December 23, 2014 By etariff Filing Hon. Kimberly D. Bose, Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, DC 20426 Re: Nevada Power Company and Sierra Pacific Power Company,

More information

WECC Guideline: UNSCHEDULED FLOW REDUCTION GUIDELINE

WECC Guideline: UNSCHEDULED FLOW REDUCTION GUIDELINE The content of this document is an excerpt of the WECC Unscheduled Flow Mitigation Plan Document posted on www.wecc.biz. Introduction WECC : UNSCHEDULED FLOW REDUCTION GUIDELINE The combination of Scheduled

More information

TUCSON ELECTRIC POWER COMPANY. Transmission Reliability Margin Implementation Document (TRMID)

TUCSON ELECTRIC POWER COMPANY. Transmission Reliability Margin Implementation Document (TRMID) A UniSource Energy Company TUCSON ELECTRIC POWER COMPANY Transmission Reliability Margin Implementation Document (TRMID) Approved by: Effective Date: /c Version 1 Based on North American Electric Reliability

More information

CURTAILMENT OF TRANSMISSION AND ENERGY

CURTAILMENT OF TRANSMISSION AND ENERGY CURTAILMENT OF TRANSMISSION AND ENERGY In this Section: Overview Scheduling Limit (SL) Curtailment Priority - Transmission Curtailment Priority - Energy Curtailment Process Curtailment of Losses Reloads

More information

Procedure for ERO Support of Frequency Response and Frequency Bias Setting Standard

Procedure for ERO Support of Frequency Response and Frequency Bias Setting Standard Procedure for ERO Support of Frequency Response and Frequency Bias Setting Standard I Table of Contents Preface... iii Introduction...iiv Chapter 1: Event Selection Process... 1 Event Selection Objectives...

More information

PacifiCorp. Transferred Frequency Response Request for Proposals (2017 TFR RFP) ISSUED: Thursday, January 12, 2017 DUE DATE: Tuesday, January 24, 2017

PacifiCorp. Transferred Frequency Response Request for Proposals (2017 TFR RFP) ISSUED: Thursday, January 12, 2017 DUE DATE: Tuesday, January 24, 2017 PacifiCorp Transferred Frequency Response Request for Proposals (2017 TFR RFP) ISSUED: Thursday, January 12, 2017 DUE DATE: Tuesday, January 24, 2017 RFP Page 1 of 9 This Transferred Frequency Response

More information

Future Development Plan:

Future Development Plan: Standard BAL-007-1 Balance of Resources and Demand Standard Development Roadmap This section is maintained by the drafting team during the development of the standard and will be removed when the standard

More information

Information Document Available Transfer Capability and Transfer Path Management ID # R

Information Document Available Transfer Capability and Transfer Path Management ID # R Information Documents are not authoritative. Information Documents are for information purposes only and are intended to provide guidance. In the event of any discrepancy between an Information Document

More information

Flexible Capacity Requirements for 2019 through 2021

Flexible Capacity Requirements for 2019 through 2021 Flexible Capacity Requirements for 2019 through 2021 Clyde Loutan - Principal, Renewable energy Integration Amber Motley - Manager, Short Term Forecasting Stakeholder Conference Call January 29 th, 2018

More information

Re: NERC Notice of Penalty regarding East Kentucky Power Cooperative, FERC Docket No. NP10-_-000

Re: NERC Notice of Penalty regarding East Kentucky Power Cooperative, FERC Docket No. NP10-_-000 November 13, 2009 Ms. Kimberly Bose Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, D.C. 20426 Re: NERC Notice of Penalty regarding East Kentucky Power Cooperative, FERC

More information

Does Inadvertent Interchange Relate to Reliability?

Does Inadvertent Interchange Relate to Reliability? [Capitalized words will have the same meaning as listed in the NERC Glossary of Terms and Rules of Procedures unless defined otherwise within this document.] INADVERTENT INTERCHANGE Relationship to Reliability,

More information

Comments of Pacific Gas & Electric Company Energy Imbalance Market Draft Tariff Language

Comments of Pacific Gas & Electric Company Energy Imbalance Market Draft Tariff Language Comments of Pacific Gas & Electric Company Energy Imbalance Market Draft Tariff Language Submitted by Company Date Submitted Will Dong Paul Gribik (415) 973-9267 (415) 973-6274 PG&E December 5, 2013 Pacific

More information

WECC Compliance Presentation to the WIRAB

WECC Compliance Presentation to the WIRAB WECC Compliance Presentation to the WIRAB Presented By Ken Driggs, Assistant Director, Training WECC Steve Rueckert, Director, Standards and Compliance - WECC May 23, 2006 2 Overview of Items to be Covered

More information

Project Phase 2.1 BARC. September 1, 2015

Project Phase 2.1 BARC. September 1, 2015 Project 2010-14.2.1 Phase 2.1 BARC September 1, 2015 Antitrust Guidelines NERC Antitrust Guidelines It is NERC s policy and practice to obey the antitrust laws and to avoid all conduct that unreasonably

More information

Western Area Power Administration-Rocky Mountain Region

Western Area Power Administration-Rocky Mountain Region Western Area Power Administration-Rocky Mountain Region Revision Date CURRENT BUSINESS PRACTICES Effective Date: October 1, 2017 Business Practices Revision Table (Changes to the business rules for this

More information

Governance - Concepts

Governance - Concepts EIM FERC Jurisdiction and Governance - Concepts A WSPP Perspective Arnold Podgorsky WSPP General Counsel April 10, 2012 www.wrightlaw.com Today s Presentation Nature of FERC jurisdiction over EIM and Market

More information

WECC Process for Risk-Based Compliance Oversight Inherent Risk Assessment and Compliance Oversight Plan

WECC Process for Risk-Based Compliance Oversight Inherent Risk Assessment and Compliance Oversight Plan WECC Process for Risk-Based Compliance Oversight Inherent Risk Assessment and Compliance Oversight Plan WECC Entity Oversight Effective Date: April 1, 2017 155 North 400 West, Suite 200 Salt Lake City,

More information

BAL Disturbance Control Standard Contingency Reserve for Recovery from a Balancing Contingency Event

BAL Disturbance Control Standard Contingency Reserve for Recovery from a Balancing Contingency Event A. Introduction 1. Title: Disturbance Control Standard Contingency Reserve for Recovery from a 2. Number: BAL-002-3 3. Purpose: To ensure the Balancing Authority or Reserve Sharing Group balances resources

More information

Attachment A. BAL Frequency Response & Frequency Bias Setting Standard. Supporting Document

Attachment A. BAL Frequency Response & Frequency Bias Setting Standard. Supporting Document Attachment A BAL-003-1 Frequency Response & Frequency Bias Setting Standard Frequency Response Obligation (FRO) for the Interconnection The ERO, in consultation with regional representatives, has established

More information

Significant negative consequences of the proposed standard include but are not limited to: 1) The proposed language moves this project from being a

Significant negative consequences of the proposed standard include but are not limited to: 1) The proposed language moves this project from being a or group. (28 Responses) Name (13 Responses) Organization (13 Responses) Name (15 Responses) Lead Contact (15 Responses) Contact Organization (15 Responses) Question 1 (28 Responses) Northeast Power Coordinating

More information

WECC Criterion TPL-001-WECC-CRT-3.1

WECC Criterion TPL-001-WECC-CRT-3.1 WECC Criterion TPL-001-WECC-CRT-3.1 A. Introduction 1. Title: Transmission System Planning Performance 2. Number: TPL-001-WECC-CRT-3.1 3. Purpose: To facilitate coordinated near-term and long-term transmission

More information

1. Title: Qualified Transfer Path Unscheduled Flow (USF) Relief

1. Title: Qualified Transfer Path Unscheduled Flow (USF) Relief A. Introduction 1. Title: Qualified Transfer Path Unscheduled Flow (USF) Relief 2. Number: IRO-006-WECC-2 3. Purpose: Mitigation of transmission overloads due to unscheduled flow on Qualified Transfer

More information

Standard INT Interchange Initiation and Modification for Reliability

Standard INT Interchange Initiation and Modification for Reliability A. Introduction 1. Title: Interchange Initiation and Modification for Reliability 2. Number: INT-010-2 3. Purpose: To provide guidance for required actions on Confirmed Interchange or Implemented Interchange

More information

Path Operator Implementation Task Force. Vic Howell, Vice Chair Report to OC March 22, 2016

Path Operator Implementation Task Force. Vic Howell, Vice Chair Report to OC March 22, 2016 Path Operator Implementation Task Force Vic Howell, Vice Chair Report to OC March 22, 2016 2 Agenda New Paradigm Review Industry Update Objective of today s presentation is to approve the following documents:

More information

BEFORE THE NEW MEXICO PUBLIC REGULATION COMMISSION ) ) ) ) ) ) ) ) ) ) ) DIRECT TESTIMONY RUTH M. SAKYA. on behalf of.

BEFORE THE NEW MEXICO PUBLIC REGULATION COMMISSION ) ) ) ) ) ) ) ) ) ) ) DIRECT TESTIMONY RUTH M. SAKYA. on behalf of. BEFORE THE NEW MEXICO PUBLIC REGULATION COMMISSION IN THE MATTER OF SOUTHWESTERN PUBLIC SERVICE COMPANY S INTERIM REPORT ON ITS PARTICIPATION IN THE SOUTHWEST POWER POOL REGIONAL TRANSMISSION ORGANIZATION,

More information

WECC Criterion PRC-(012 through 014)-WECC-CRT-2.2

WECC Criterion PRC-(012 through 014)-WECC-CRT-2.2 A. Introduction WECC Criterion PRC-(012 through 014)-WECC-CRT-2.2 1. Title: Remedial Action Scheme Review and Assessment Plan 2. Number: PRC-(012 through 014)-WECC-CRT-2.2 3. Purpose: To: 1) establish

More information

CURTAILABLE RATE PROGRAM FOR INDIVIDUAL CUSTOMER LOADS

CURTAILABLE RATE PROGRAM FOR INDIVIDUAL CUSTOMER LOADS CURTAILABLE RATE PROGRAM FOR INDIVIDUAL CUSTOMER LOADS PROPOSED TERMS AND CONDITIONS TABLE OF CONTENTS 1. Definitions... 1 2. Curtailable Load Options... 4 3. Nomination of Curtailable Load... 5 4. Curtailable

More information

SOUTHERN CALIFORNIA EDISON COMPANY TRANSMISSION OWNER TARIFF

SOUTHERN CALIFORNIA EDISON COMPANY TRANSMISSION OWNER TARIFF Southern California Edison Company FERC Electric Tariff, Second Revised Volume No. 6 Title Page SOUTHERN CALIFORNIA EDISON COMPANY TRANSMISSION OWNER TARIFF Issued on: December 23, 2002 Effective: January

More information

Please contact the undersigned if you have any questions concerning this filing.

Please contact the undersigned if you have any questions concerning this filing. !! November 17, 2016 VIA ELECTRONIC FILING Ms. Katie Mitchell Chief Clerk New Brunswick Energy and Utilities Board P.O. Box 5001 15 Market Square, Suite 1400 Saint John, NB E2L 4Y9 Re: North American Electric

More information

ISO filed a tariff amendment to implement the rates, terms, and conditions of the ISO s Reliability Coordinator Service

ISO filed a tariff amendment to implement the rates, terms, and conditions of the ISO s Reliability Coordinator Service California Independent System Operator Corporation Memorandum To: ISO Board of Governors From: Roger Collanton, Vice President, General Counsel, Chief Compliance Officer, and Corporate Secretary Date:

More information

CONTROL AREA SERVICES AND OPERATIONS TARIFF OTTER TAIL POWER COMPANY

CONTROL AREA SERVICES AND OPERATIONS TARIFF OTTER TAIL POWER COMPANY Otter Tail Power Company Original Sheet No. 1 CONTROL AREA SERVICES AND OPERATIONS TARIFF OTTER TAIL POWER COMPANY Otter Tail Power Company Substitute Original Sheet No. 2 Superseding Original Volume No.

More information

Western Interconnection Unscheduled Flow Mitigation Plan, (WIUFMP)

Western Interconnection Unscheduled Flow Mitigation Plan, (WIUFMP) Western Interconnection Unscheduled Flow Mitigation Plan, (WIUFMP) Purpose: The purpose of the Western Interconnection Unscheduled Flow Mitigation Plan (WIUFMP) is to mitigate flows on Qualified Paths

More information

NERC TPL Standard Overview

NERC TPL Standard Overview NERC TPL-001-4 Standard Overview Attachment K Quarter 3 Stakeholder s Meeting September 29, 2016 1 Background New NERC TPL Standard 2016 TPL Plan and Status Update 2015 Planning Assessment Results Compliance

More information

NAESB RAI Submission and Response Timetable

NAESB RAI Submission and Response Timetable NAESB RAI Submission and Response Timetable Document Subsections A. Eastern Interconnection New Transactions B. Western Interconnection New Transactions C. Interchange Transaction Corrections D. Interchange

More information

Violation Risk Factor and Violation Severity Level Justifications Project Modifications to BAL

Violation Risk Factor and Violation Severity Level Justifications Project Modifications to BAL Violation Risk Factor and Violation Severity Level Justifications Project 2017-01 Modifications to BAL-003-1.1 This document provides the standard drafting team s (SDT s) justification for assignment of

More information

March 7, The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, NE Washington, DC 20426

March 7, The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, NE Washington, DC 20426 California Independent System Operator Corporation The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, NE Washington, DC 20426 March 7, 2012 Re: California Independent

More information

Consumer Requirements for Distributed Generation Installation and Interconnection

Consumer Requirements for Distributed Generation Installation and Interconnection Rio Grande Electric Cooperative, Inc. Consumer Requirements for Distributed Generation Installation and Interconnection (Click on links to be taken to the appropriate page) TABLE OF CONTENTS SECTION PAGE

More information

ASSOCIATED ELECTRIC COOPERATIVE, INC. OPEN ACCESS TRANSMISSION TARIFF

ASSOCIATED ELECTRIC COOPERATIVE, INC. OPEN ACCESS TRANSMISSION TARIFF ASSOCIATED ELECTRIC COOPERATIVE, INC. OPEN ACCESS TRANSMISSION TARIFF BUSINESS PRACTICES Revised January 21, 2015 Effective January 21, 2015 Business Practice Revision History Revision Number Effective

More information

EXCERPTS from the SAMS-SPCS SPS Technical Reference

EXCERPTS from the SAMS-SPCS SPS Technical Reference Problem Statement The existing NERC Glossary of Terms definition for a Special Protection System (SPS or, as used in the Western Interconnection, a Remedial Action Scheme or RAS) lacks clarity and specificity

More information

15.4 Rate Schedule 4 - Payments for Supplying Operating Reserves

15.4 Rate Schedule 4 - Payments for Supplying Operating Reserves 15.4 Rate Schedule 4 - Payments for Supplying Operating Reserves This Rate Schedule applies to payments to Suppliers that provide Operating Reserves to the ISO. Transmission Customers will purchase Operating

More information

Five-Minute Settlements Education

Five-Minute Settlements Education Five-Minute Settlements Education Disclaimer PJM has made all efforts possible to accurately document all information in this presentation. The information seen here does not supersede the PJM Operating

More information

Title Page Southern California Edison Company Tariff Title: Transmission Owners Tariff Tariff Record Title: First Revised Service Agreement No. 39 FER

Title Page Southern California Edison Company Tariff Title: Transmission Owners Tariff Tariff Record Title: First Revised Service Agreement No. 39 FER Title Page Southern California Edison Company Tariff Title: Transmission Owners Tariff Tariff Record Title: First Revised Service Agreement No. 39 FERC FPA Electric Tariff INTERCONNECTION FACILITIES AGREEMENT

More information

COMMENTS OF NV ENERGY LOCAL MARKET POWER MITIGATION ENHANCEMENTS DRAFT FINAL PROPOSAL DATED JANUARY 31, 2019 CAISO STAKEHOLDER PROCESS

COMMENTS OF NV ENERGY LOCAL MARKET POWER MITIGATION ENHANCEMENTS DRAFT FINAL PROPOSAL DATED JANUARY 31, 2019 CAISO STAKEHOLDER PROCESS COMMENTS OF NV ENERGY LOCAL MARKET POWER MITIGATION ENHANCEMENTS DRAFT FINAL PROPOSAL DATED JANUARY 31, 2019 CAISO STAKEHOLDER PROCESS February 8 th, 2019 NV Energy appreciates the opportunity to comment

More information

Stochastic Loss of Load Study for the 2011 Integrated Resource Plan

Stochastic Loss of Load Study for the 2011 Integrated Resource Plan November 18, 2010 Stochastic Loss of Load Study for the 2011 Integrated Resource Plan INTRODUCTION PacifiCorp evaluates the desired level of capacity planning reserves for each integrated resource plan.

More information

MEMORANDUM. June 6, 2012

MEMORANDUM. June 6, 2012 MEMORANDUM June 6, 2012 To: WSPP Participants From: Arnie Podgorsky Patrick Morand Re: California Cap and Trade: Potential WSPP Impacts This memorandum summarizes aspects of the cap and trade program (

More information

Group Arizona Public Service Company Janet Smith, Regulatory Affairs Supervisor Yes. Yes. Group Salt River Project Chris Chavez for Mike Gentry Yes

Group Arizona Public Service Company Janet Smith, Regulatory Affairs Supervisor Yes. Yes. Group Salt River Project Chris Chavez for Mike Gentry Yes Name (1 Responses) Organization (1 Responses) Name (5 Responses) Lead Contact (5 Responses) Question 1 (6 Responses) Question 1 Comments (6 Responses) Question 2 (6 Responses) Question 2 Comments (6 Responses)

More information

September 30, Ms. Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, DC 20426

September 30, Ms. Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, DC 20426 September 30, 2013 Ms. Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, DC 20426 Re: NERC Full Notice of Penalty regarding ISO New England, Inc. FERC Docket

More information

GENERAL OVERVIEW OF DRAFT PEAK RELIABILITY FUNDING AGREEMENT

GENERAL OVERVIEW OF DRAFT PEAK RELIABILITY FUNDING AGREEMENT GENERAL OVERVIEW OF DRAFT PEAK RELIABILITY FUNDING AGREEMENT DISCLAIMER: This document is a general overview that is intended to provide a plain language overview of a number of provisions of the Draft

More information

DRAFT REQUEST FOR PROPOSALS BY THE ARIZONA POWER AUTHORITY FOR SCHEDULING SERVICES AND/OR USE OF HOOVER DAM DYNAMIC SIGNAL.

DRAFT REQUEST FOR PROPOSALS BY THE ARIZONA POWER AUTHORITY FOR SCHEDULING SERVICES AND/OR USE OF HOOVER DAM DYNAMIC SIGNAL. DRAFT REQUEST FOR PROPOSALS BY THE ARIZONA POWER AUTHORITY FOR SCHEDULING SERVICES AND/OR USE OF HOOVER DAM DYNAMIC SIGNAL March 31, 2017 Summary The Arizona Power Authority ( Authority ) recently signed

More information

BAL-005-1, BAL & FAC December 18, 2017

BAL-005-1, BAL & FAC December 18, 2017 BAL-005-1, BAL-006-2 & FAC-001-3 December 18, 2017 Antitrust Guidelines NERC Antitrust Guidelines It is NERC s policy and practice to obey the antitrust laws and to avoid all conduct that unreasonably

More information

WECC Criterion PRC-001-WECC-CRT-2

WECC Criterion PRC-001-WECC-CRT-2 A. Introduction 1. Title: Governor Droop Setting 2. Number: 3. Purpose: To facilitate primary frequency support in the Western Interconnection 4. Applicability: 1.1. Functional Entities: 4.1.1. Generator

More information

May 28, Southwest Power Pool, Inc., Docket No. ER15- Submission of Notice of Cancellation of Interconnection Agreement

May 28, Southwest Power Pool, Inc., Docket No. ER15- Submission of Notice of Cancellation of Interconnection Agreement May 28, 2015 The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street NE Washington, DC 20426 RE: Southwest Power Pool, Inc., Docket No. ER15- Submission of Notice

More information

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION ) )

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION ) ) UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION North American Electric Reliability Corporation ) ) Docket No. PETITION OF THE NORTH AMERICAN ELECTRIC RELIABILITY CORPORATION FOR

More information

Real-Time Reserves. Vince Stefanowicz Sr. Lead Engineer, Generation Operating Committee May 1, PJM 2018

Real-Time Reserves. Vince Stefanowicz Sr. Lead Engineer, Generation Operating Committee May 1, PJM 2018 Real-Time Reserves Vince Stefanowicz Sr. Lead Engineer, Generation Operating Committee May 1, 2018 Timeline / Work Plan OC (3/6/18) Education OC (4/3/18) Education Feedback OC (5/1/18) Review Analysis

More information

Business Practice Manual For The Energy Imbalance Market. Version 1213

Business Practice Manual For The Energy Imbalance Market. Version 1213 Business Practice Manual For The Energy Imbalance Market Version 1213 Revision Date: October 25 November 29, 2018 Approval History Approval Date: October 2, 2014 Effective Date: October 2, 2014 BPM Owners:

More information

Ken Gartner, CMEP Process Principal November 28, 2017

Ken Gartner, CMEP Process Principal November 28, 2017 MIDWEST RELIABILITY ORGANIZATION 2018 MRO CMEP Implementation Plan Ken Gartner, CMEP Process Principal November 28, 2017 Improving RELIABILITY and mitigating RISKS to the Bulk Power System 2018 ERO CMEP

More information

Standard Development Timeline

Standard Development Timeline Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Description of Current Draft

More information

BILLING CODE P DEPARTMENT OF ENERGY Federal Energy Regulatory Commission. [Docket No. IC ]

BILLING CODE P DEPARTMENT OF ENERGY Federal Energy Regulatory Commission. [Docket No. IC ] This document is scheduled to be published in the Federal Register on 07/21/2014 and available online at http://federalregister.gov/a/2014-17044, and on FDsys.gov BILLING CODE 6717-01-P DEPARTMENT OF ENERGY

More information

PRC Remedial Action Schemes

PRC Remedial Action Schemes PRC-012-2 Remedial Action Schemes A. Introduction 1. Title: Remedial Action Schemes 2. Number: PRC-012-2 3. Purpose: To ensure that Remedial Action Schemes (RAS) do not introduce unintentional or unacceptable

More information

Standard BAL Real Power Balancing Control Performance

Standard BAL Real Power Balancing Control Performance A. Introduction 1. Title: Real Power Balancing Control Performance 2. Number: BAL 001 2 3. Purpose: To control Interconnection frequency within defined limits. 4. Applicability: 4.1. Balancing Authority

More information

CURTAILMENT OF TRANSMISSION AND ENERGY

CURTAILMENT OF TRANSMISSION AND ENERGY CURTAILMENT OF TRANSMISSION AND ENERGY In this Section: Overview Scheduling Limit (SL) Curtailment Priority - Transmission Curtailment Priority - Energy Curtailment Process Curtailment of Losses Reloads

More information

10-YEAR COSTS AND BENEFITS TO SPP MEMBERS OF INTEGRATING MOUNTAIN WEST TRANSMISSION GROUP Quantitative Analysis of Costs and Benefits

10-YEAR COSTS AND BENEFITS TO SPP MEMBERS OF INTEGRATING MOUNTAIN WEST TRANSMISSION GROUP Quantitative Analysis of Costs and Benefits 10-YEAR COSTS AND BENEFITS TO SPP MEMBERS OF INTEGRATING MOUNTAIN WEST TRANSMISSION GROUP Quantitative Analysis of Costs and Benefits Published on March 19, 2018 By SPP Staff REVISION HISTORY DATE OR VERSION

More information

130 FERC 61,033 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION. [Docket No. RM ]

130 FERC 61,033 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION. [Docket No. RM ] 130 FERC 61,033 UNITED STATES OF AMERICA FEDERAL ENERGY REGULATORY COMMISSION [Docket No. RM10-9-000] Transmission Loading Relief Reliability Standard and Curtailment Priorities (Issued January 21, 2010)

More information

TECHNICAL BULLETIN 27

TECHNICAL BULLETIN 27 NEW YORK INDEPENDENT SYSTEM OPERATOR TECHNICAL BULLETIN 27 12/19/2006; recertified 12/21/10, revised 7/5/11,10/19/2011,06/18/2012, mm/dd/2014 Subject: NERC E-Tags convey transaction details to Balancing

More information

WSPP Legal Update Operating Committee Meeting Lake Tahoe

WSPP Legal Update Operating Committee Meeting Lake Tahoe WSPP Legal Update Operating Committee Meeting Lake Tahoe March 4-6, 2013 Arnie Podgorsky and Patrick Morand Wright & Talisman, PC Washington, DC These are training materials and do not contain legal advice

More information

WECC Criterion PRC-003-WECC-CRT-1.3

WECC Criterion PRC-003-WECC-CRT-1.3 WECC Criterion PRC-003-WECC-CRT-1.3 A. Introduction 1. Title: Analysis, Reporting, and Mitigation of Transmission and Generation Protection System and Remedial Action Scheme Misoperations Procedure 1 2.

More information

Operating Procedure PURPOSE... 1

Operating Procedure PURPOSE... 1 No. 3640 Table of Contents PURPOSE... 1 1. RESPONSIBILITIES... 2 2. SCOPE/APPLICABILITY... 2 2.1. Background... 3 2.2. Scope/ Applicability... 3 3. PROCEDURE DETAIL... 3 3.1. ISO Day-Ahead Operations Engineer

More information

Trade a directional bias with a limited and identifiable risk exposure. Protect and preserve investment capital.

Trade a directional bias with a limited and identifiable risk exposure. Protect and preserve investment capital. Disclaimer The views and opinions expressed in this presentation reflect those of the individual authors/presenters only and do not represent in any way Bourse de Montréal Inc. s (the Bourse ) opinion

More information

Update on EPA s Proposed GHG Rule for Existing Power. Clare Breidenich Western Power Trading Forum WSPP Operating Committee March 11, 2015

Update on EPA s Proposed GHG Rule for Existing Power. Clare Breidenich Western Power Trading Forum WSPP Operating Committee March 11, 2015 Update on EPA s Proposed GHG Rule for Existing Power Plants Clare Breidenich Western Power Trading Forum WSPP Operating Committee March 11, 2015 Overview of 111(d) Proposal Sets rate-based emission performance

More information

Paragraph 81 Project Technical White Paper

Paragraph 81 Project Technical White Paper Paragraph 81 Project Technical White Paper December 20, 2012 Table of Contents I. Introduction...4 A. Consensus Process...4 B. Standards Committee...5 II. Executive Summary...6 III. Criteria...7 Criterion

More information