Building Envelope Retro- Commissioning for Safe Havens

Similar documents
Property Assessed Clean Energy Programs and How PACE Can Benefit Your Community

Westmount Place Renovations Policy

National Institute of Building Sciences

Home Performance with Energy Star Loan Policy

Our Focus: Your Future

QUICK GUIDE. An Introduction to COPE Data. Copyright 2017 AssetWorks Inc. All Rights Reserved. For more information visit,

City School District of Albany Five Year Facilities Plan 3/14/2019

Condominium Property Act & Regulation

Residential Property Deduction Schedule

Listing of Events Fort McMurray Roman Catholic Seperate School District Fr. M. Beauregard School

Contractor Application Instructions

Addendum: SIU Cases of Interest

Hayfield Community Schools Bond Referendum. Vote Monday, September 11, Our Schools Our Communities Our Future

ORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 6/19/2013 BUILDING SURVEY DATE

What did they tell me?

FHA Renovation Loan Program, or 203K

Putnam Valley Library Use of Meeting Room Policy

Hurricane Preparedness Plan The Cotton Mill Condominiums

REPLACEMENT RESERVE GUIDE

AIA Middle East. The Safety Design in Buildings Conference. Hermann Frankfurth A309. PROPERTY PROTECTION an Insurer s view. September/October 2013

ORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 4/19/2013 BUILDING SURVEY DATE

2011 CONNECTICUT. Residential Quality Installation And Verification Contractor Application !" # $!% &!

Sample Contract and Work Scope

Fee Schedule for 2017

For. 621 Grant. Yakima, WA until: preparation. Kim Hixson Director

Managing Risks with Hazardous Substances RLI Design Professionals Design Professionals Learning Event DPLE 154 May 6, 2015

Taking the Wind Out of Hurricane Damage

CAPITAL RESERVE FUNDING ANALYSIS

Net Zero Energy Feasibility Study Summary report

Oak Island 1999 Hurricane Floyd

ORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 02/08/2013 BUILDING SURVEY DATE

Building Codes. BOCA / Simon Tenant Construction Manual. Plumbing: National Standard Plumbing Code as modified /Simon Tenant Construction Manual

DISASTER RELIEF : INSURANCE RECOVERY

William Bradley Bryant Center

NC School District/430 Harnett County/Middle School Highland Middle Final Campus Assessment Report March 11, 2017

Ameren Low-Income Weatherization Program. Final Evaluation Report

Ketchikan Indian Community Housing Authority

1.1 This annex is used when assessing the extent of property damage affecting WVU Beckley property after an accident, emergency, or disaster.

Allow nature to be your guide and select from among more than 2000 acres of our magnificent mountain properties. Chinquapin was designed to maintain

ORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 2/6/2013 BUILDING SURVEY DATE

CA IOU Programs for Low Income Energy Efficiency

Anchor Property Holdings Ltd Easy Read Maintenance Policy

This notice is referenced in an endnote at the Bradford Tax Institute. CLICK HERE to go to the home page. Q&A on Tax Credits for Sections 25C and 25D

Garden City Public Schools Capital Reserve. Presentation to the Board of Education January 10, 2017

SERVICE PROVIDER INFORMATION

Industry Drivers of Commissioning: Programs & Legislation


LIMITED WARRANTY AGREEMENT FOR WEATHER-TIGHTNESS LIMITED WARRANTY

Facility Condition Assessment Report. Coast Community College District

Residential Low-Interest Loan with Rebate. Customer Instructions HVAC, Insulation, Windows & Doors Offer valid until funding expires

NUNAVUT HOUSING CORPORATION. Home Renovation Program (HRP)

Lesson 2: The Homeowners Policy

Subject: Capital Reserve Expenditure Guidelines. *incl. former OCHAP/CSHP Peel Access to Housing (PATH)

NUNAVUT HOUSING CORPORATION. Emergency Repair Program (ERP)

CITY OF TAMARAC BUILDING DEPARTMENT Schedule of Permit Fees

ATTIC FAN - DECEMBER 1995

Subcontractor Contract and Scope of Work MECHANICAL Social Security Administration Auburn, AL Ross Clark Circle Dothan, Alabama 36301

A Review of Current Occupational Safety and Health in the Washington Cannabis Industry

Hurricane Preparedness

Cottonwoods at Vine. Reserve Study. October 2012

Home Buyer Pre Lending Package

CONTRACTORS PROTECTOR PROGRAM

CONTRACTORS PROTECTOR PROGRAM

DIFFERENCE IN CONDITIONS HOMEOWNERS ASSOCIATION COVERAGE EXTENSION

MIP CONFERENCE FACILITY SCHEDULE A - TERMS & CONDITIONS

Sagamore Hills Elementary

Hurricane and flood preparation checklist. Preparation and response key to minimizing damage and loss

ORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 4/11/2013 BUILDING SURVEY DATE

Should I Go or Should I Not Go? DPLE 175 January 18, 2017

Help Others Prepare for a Hurricane

CITY OF FORT PIERCE BUILDING DEPARTMENT

Laurel Hill Elementary

SASKATCHEWAN OCCUPATIONAL HEALTH AND SAFETY REGULATIONS

My Home is Damaged. Now What? Kuhl Design+Build, LLC 1515 South 5th Street, Hopkins, MN

FILED: NEW YORK COUNTY CLERK 07/13/ :02 PM INDEX NO /2016 NYSCEF DOC. NO. 1 RECEIVED NYSCEF: 07/13/2016

TO MEMBERS OF THE COMMITTEE ON GROUNDS AND BUILDINGS: ACTION ITEM

What Service Measureables Really Mean

Residents of your household who are your relatives or other persons under the age of 21 and in the care of any person named above

CIP FY2015 FY2019 Requests SCH-1, SCH-2 and SCH-5

Pleasantdale Elementary

30-34 Pearsall Owners Corporation Pearsall Avenue Glen Cove, NY

EXHIBIT B. Filed 8/10/2015 6:09:57 PM Esther Degollado District Clerk Webb District <<Name>> 2015CV D5

The Grande Phoenician at the Grande Preserve Condominium Association, Inc.

DeKalb County School District/Elementary Schools Dunwoody Elementary Final School Assessment Report May 19, 2016

ORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 6/4/2013 BUILDING SURVEY DATE

Make a Plan. Slide 1. Slide 2

Ongo Homes Maintenance Services Policy

Contact Position Telephone Fax Lending Institution s Reference Code Loan Venue Address

RENOVATE AMERICA GREEN BOND PRE-ISSUANCE REVIEW

THE CLARIDGE OF POMPANO CONDOMINIUM, INC. ARCHITECTURAL REVIEW COMMITTEE REQUEST FOR MODIFICATION PART A - COMPLETED BY OWNER

ORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 6/5/2013 BUILDING SURVEY DATE

WATER EXCLUSION ENDORSEMENT

Residential Standard Offer Program

A ROUGH INSPECTION for all DUCTWORK must be completed PRIOR to a BUILDING FRAME INSPECTION

Floodplain Design, Construction, and Impacts On Flood Insurance

RAA Trade Assist Terms and Conditions

Integrating Green Building Measures into Capital Planning for HUD Assisted and Public Housing Programs

Stone Mountain Middle

COUNCIL REPORT TO THE CHIEF ADMINISTRATIVE OFFICER FROM THE PARKS, RECREATION, AND CULTURAL SERVICES DEPARTMENT WESTSYDE POOL ROOF REPAIR UPDATE

LIVINGSTON COUNTY BOARD PROPERTY COMMITTEE MINUTES OF NOVEMBER 6, 2017

Transcription:

Building Envelope Retro- Commissioning for Safe Havens Francis Conlin & Meghan McDermott High Performance Building Solutions, Inc.

Air Barrier Association of America (ABAA) is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will be reported to CES Records for AIA members. Certificates of Completion for non-aia members are available on request. This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product.

Learning Objectives 1. Participants will be able to compare air leakage test results of various Safe Havens to known standards. 2. Participants will be able to evaluate potential areas as viable or nonviable Safe Havens. 3. Participants will be able to test and predict the air leakage rate of Safe Havens. 4. Participants will be able to identify common recommendations for reducing air leakage in Safe Havens.

What is a Safe Haven Shelter-In-Place: A strategy to seek shelter and stay put in the event of danger. Safe Haven: A shelter designed to protect occupants from one or more types of danger. Can be stand alone or modified from existing buildings.

Industrial Applications Needs for Safe Havens In this project, the danger is accidental release of anhydrous ammonia at industrial sites.

Safe Haven or 15-Minute Escape Pack

Safe Haven or 15-Minute Escape Pack Ammonia Release The IDLH for ammonia is 300 ppm. Coughing and bronchial spasms will occur at 1700 ppm. 30 minute exposure at 2000 to 3000 ppm may be fatal. Fatal at 10,000 ppm or 1% by volume.

Retro-Commissioning Existing Building as a Safe Haven from Chemical Release Air Seal Envelope Close off HVAC Isolate HVAC from outdoor air & other spaces Air seal all penetrations & fenestrations

FEMA 453 Design Guidance for Shelters and Safe Rooms Selecting Location: 5 SF per Person Few to no windows No suspended ceiling Minimum number of doors Interior rooms preferable Away from toxic material storage HVAC System Issues simple is best Water, bathrooms

FEMA 453 Design Guidance for Shelters and Safe Rooms

Right Sizing

Selecting a Safe Haven

Selecting a Safe Haven

Selecting a Safe Haven

Viable or Nonviable?

Viable or Nonviable

Break Areas to Become Safe Havens Easy to work around Slab Floor with no penetrations No sensitive equipment Noise is not an issue

Control Rooms to Become Safe Havens Difficult to work around, tether all equipment including hard hats Many cable penetrations through the floor Sensitive (old) equipment can t bump Low noise requirement

Safe Haven Project Evaluated 40 Safe Havens 7 Different Power Plants 3 Different States FEMA 453 Guide FEMA does not specify air tightness criteria

Safe Haven Retro-Commissioning Evaluation Phase Pre Weatherization & MEP Measurement Implementation Phase Weatherization Work & MEP Post Evaluation Phase Measurement & Verification Continual Monitoring Phase

Air Leakage Testing Safe Havens ASTM E 779 No taping HVAC Pressurization Only Results: ACHn CFM75/SF CFM @ 4 Pascals

ACHnatural Safe Haven Leakage Rate (ACHnatural) 5.00 4.50 4.00 3.50 3.00 2.50 2.00 Estimated ACHn Measured ACHn 1.50 1.00 0.50 0.00 0 5 10 15 20 25 30 35 40 45 Safe Haven

Air Leakage from FEMA 453

CFM75/SF 4.00 Safe Haven Leakage Rate (CFM75/SF) 3.50 3.00 2.50 2.00 1.50 1.00 0.50 0.00 0 5 10 15 20 25 30 35 40 45 Safe Haven 0.25 CFM75/SF

CFM @ 4 Pascals 8,000 CFM Required to Maintain Positive Pressure with 5 mph Wind 7,000 6,000 5,000 4,000 3,000 2,000 1,000 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 Safe Haven Spaces

Weatherizing Safe Havens Envelope Walls Floors Ceilings MEP Lights HVAC Sprinklers

Envelope Air Sealing Blower Door Directed Air Sealing Typical Penetrations Windows Recessed Lights Interior Walls

Blower Door Directed Air Sealing

Tricky Walls

Envelope - Ceilings Suspended Ceiling System Can Work Becomes the Air Barrier Cleanroom System Application: Gasketed Grid System Air Impermeable Tiles Issues with Acoustics

Lights Allows leakage through the suspended ceiling system Recommend: Airtight Recessed Cleanroom Style Fixtures

HVAC Isolate the Safe Haven Supply Ducts Return Ducts/Plenum Exhaust Fans Outdoor Air System Low Leakage Dampers Emergency Shut Off

HVAC

Sprinklers Cleanroom Style Sprinklers Make air tight connection to suspended ceiling system

CFM 75/SF Pre and Post Results 3.50 Air Leakage Reduction 3.10 3.00 2.50 2.00 1.90 1.50 1.00 0.50 0.53 0.18 0.15 0.25 0.08 0.51 0.00 1 2 3 4 Pre Weatherization Air Leakage Post Weatherization Air Leakage

Retro BECx Case Study Manufacturing Facility Statesville Manufacturing Facility 100 Year Old Building Roll-Up Door ASTM E 779 Testing Measured Air Leakage Rate: 0.0841 CFM75/SF of Envelope Area Hole Size: 1.60 SF (EqLA)

Retro BECx Case Study Manufacturing Facility Statesville

Inspection with Synthetic Smoke

Retro-BECx Case Study Pharmaceutical Refrigerator Leaky 500,000CF Cooler Condensation On Product 1. Find Leaks 2. Repair Leaks

Using Blower Door to Find Leaks

Find Leaks - Seal Leaks

Francis Conlin, Senior Engineer (919) 632-3595, fconlin@hpb-solutions.com Meghan McDermott, Architectural Engineer (704) 299-1698, Meghan@hpb-solutions.com

ThankYou!