EMC Greenplum Data Computing Appliance Site Preparation Guide

Similar documents
The MICROS Bump Bar MBB-10 and MBB-20 User s Guide

Users Guide for Ac-MINI

JADE LICENSING DOCUME N T V E R S I O N 1 2 JADE SOFTWARE CORPORATION

UN HABITAT AFGHANISTAN INVITATION TO BID (ITB) ITB No: UN/H/KBL/2016/013. Project ID: K-SMNP. Title of Work:

TENDER DOCUMENT MAINTENANCE OF PROXY SERVER NATIONAL INSTITUTE OF PUBLIC FINANCE AND POLICY. New Delhi

OMX Optical Distribution Frame

INVITATION FOR TENDER FOR SUPPLY OF EQUIPMENT

DC Power Adapter 120 VAC

Configuration Summary

PROPOSAL REQUEST FOR ERP DATA PROCESSING EQUIPMENT

Request for Quotations (Supply of Computer, UPS, Printer, USB Dongles, & Soft wares) Project: TAF-Education/SEA II Project

2001 7½-Digit High Performance Multimeter ½-Digit High Performance Multimeter

Lightstream Scroll kW ULTRACOMPACT II COMPACT AIR-COOLED CHILLERS WITH SCROLL COMPRESSORS

ASX Technical Services Schedule of Fees APRIL 2017 VERSION

ASX Technical Services

IMS-4010 Dry Contact Node User s Manual

QML35. Cover. Voltage A = 5V (+/- 5%) B = 3.3V (+/- 5%)

PrintFleet Enterprise 2.2 Security Overview

2001 7½-Digit High Performance Multimeter ½-Digit High Performance Multimeter

2001 7½-Digit High Performance Multimeter ½-Digit High Performance Multimeter

2001 7½-Digit High Performance Multimeter ½-Digit High Performance Multimeter

MRX-30 Owner s Manual

at 16:00 Hrs (Indian time)

INVITATION FOR TENDER FOR SUPPLY OF EQUIPMENT

RESOLV CONTAINER MANAGEMENT DESKTOP

INVITATION FOR BID VENDOR: BID OPENING:

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR DEPARTMENT OF CHEMICAL ENGINEERING

TENDER FOR COMPUTER WORKSTATION FOR THE INSTITUTE AT OKHLA PHASE-III, NEW DELHI (Tender no. IIITD/S&P/IT/Computer Workstation/30/ )

QM35. Cover. Output. A = Line Driver B = Line Driver (ABZ) /Open Collector (UVW) C = Dual Votage Line Driver (ABZ)/ Open Collector (UVW)

RUGGEDCOM Modules. Preface. Introduction 1. Power Supply Modules 2. Copper Ethernet Modules 3. Fiber Optic Ethernet Modules 4

Enphase. technology changes everything. See the Difference Solar Makes With MyEnlighten. Long-term reliability. More power means lower energy bills

Easystream kW PACKAGED SCROLL CHILLERS

3M Super Close Projection System SCP712

A/V PowerSaver 8 Quick Installation Guide

8508A Reference Multimeter Extended Specifications

INVITATION FOR TENDER FOR SUPPLY OF DEEP LEARNING RACK SERVER

Messages and Processor Codes March 2008

CLIMAGUARD Air-To-Air Indoor Heat Exchangers. All Models INSTRUCTION MANUAL nvent Rev. H P/N

Quick Installation Guide TEW-ASAL1 H/W: V2

VPLS Reseller Rent2Own Program Terms and Conditions

CyberSource Payment Manager 6.5 SP2

Enable-IT 828 Gigabit PoE Extender Unit Quickstart Guide

IMPROVED PRODUCT VCS331, VCS332

Vented Subwoofer Enclosure System

How to Use Tax Strategies to Offset Dealership Construction Costs Six-figure offsets are possible if you plan carefully

OPTIC FIBRE INTERNET FOR YOUR BUSINESS STANDARD SERVICE LEVEL AGREEMENT

ROURKELA SMART CITY LIMITED Rourkela Municipal Corporation, Uditnagar, Rourkela

Rev B. Getting Started with the ISDS Platform User Guide

* The connectivity provided under this section applies to ports used to connect to the re-platformed Nasdaq GEMX trading system.

Limited Warranty Guide Fujitsu Imaging Products

An Assessment of Technical Risks in PV Investments

RDP-272+ DC to 2700 MHz (DC-950, MHz) The Big Deal Low insertion loss High isolation Miniature shielded package.

DMI Certification. David G. Lawrence DMI Working Group

Invitation to Bid For 100 PC Workstations

Lightstream Scroll kW ULTRACOMPACT COMPACT AIR-COOLED CHILLERS WITH SCROLL COMPRESSORS

INVITATION FOR TENDER FOR SUPPLY OF EQUIPMENT

R-407C REFRIGERANT LORC, LNH, LNL, LNQ AND LNX SERIES OUTDOOR AIR-COOLED REMOTE CONDENSERS STANDARD FEATURES VERTICAL DISCHARGE

18 STÖGRA panel mount/19 inch-systems series ELK/ELR

Unparalleled Performance, Agility and Security for NSE

STARHUB'S SERVICE SPECIFIC TERMS & CONDITIONS BROADBAND SERVICES

Belden Overview Q Belden Inc.

PeopleSoft Enterprise ebenefits 9.1 PeopleBook

Lightstream Scroll kW ULTRACOMPACT II FREECOOL COMPACT FREE COOLING CHILLERS WITH SCROLL COMPRESSORS

Comprehensive solutions for urinalysis

Fibre Passive Devices

City of Portsmouth Portsmouth, New Hampshire Public Works Department INVITATION TO BID

Sungard Availability Services PC Refresh Programme Customer FAQ. Version No: 1.0 February INF-UKMKT-PMK-PC Refresh FAQs

EMC ViPR SRM. Chargeback Guide. Version

INVOICING INFORMATION

Comprehensive solutions for urinalysis

R-410A REFRIGERANT LORC, LNH, LNL, LNQ AND LNX SERIES OUTDOOR AIR-COOLED REMOTE CONDENSERS STANDARD FEATURES VERTICAL DISCHARGE

INVITATION FOR QUOTATION. TEQIP-III/2018/uiet/Shopping/72

SERVICE LEVEL AGREEMENT

Tender for supply/upkeep & maintenance of firewall, switches and routers for High Commission of India. Tender Notice

Contract for Network Upgrades

LM6000PD/PF 3- and 5-DVP Cabinet. Product Manual (Revision A) Original Instructions. Single or Redundant DVP Power Input Versions

Oracle GoldenGate Management Pack

MASTER SERVICE AGREEMENT

SPECIFICATION. : 2 x 4G/3G/2G MIMO Antenna (698~960MHz, 1710~2170MHz,2300~2700MHz, MHz) MIMO1 antenna MIMO2 antenna

INVITATION FOR TENDER FOR SUPPLY OF EQUIPMENT

SPECIFICATION. Product Name : Dual-Band WiFi 2.4~2.5GHz/5.15~5.85GHz Terminal Mount Monopole Antenna

Wi-Fi Hotspot Products Form ORDER ON-LINE:

Enterprise Planning and Budgeting 9.0 Created on 2/4/2010 9:42:00 AM

H.K. Desai, Chief Executive Officer Simon Biddiscombe, Sr. Vice President and CFO

DP41-TC, DP41-RTD. High Performance Temperature Indicator. Shop online at omega.com

` (A premier Public Sector Bank) Information Technology Division Head Office, Mangalore. Corrigendum 3. Tender Number: 14/ dated

Compute Managed Services Schedule to the General Terms

Fruth Group - Managed IT Services (MIS) Terms of Service (TOS)

Load Test Report. Moscow Exchange Trading & Clearing Systems. 07 October Contents. Testing objectives... 2 Main results... 2

ELECTRICAL SERVICE ORDER FORM

IBM United States Hardware Announcement , dated August 21, 2018

Belden Overview Q Belden Inc.

CyberSource Payment Manager Messages and Processor Codes

Image Key Part Number Description Substitution Qty.

VIRTUAL UNIVERSITY OF PAKISTAN M.A. Jinnah Campus, Defence Road, off. Raiwind Road, Lahore TENDER DOCUMENT

OpenScape Enterprise Express

INVITATION FOR TENDER FOR SUPPLY OF EQUIPMENT

SIAL Canada 2018 (13740) Expo Canada-France inc From 2018/05/02 to 2018/05/04

Vivid Reports 2.0 Budget User Guide

3M D Sub EMI Junction Shell Shielded Flat Cable

Transcription:

The Data Computing Division of EMC EMC Greenplum Data Computing Appliance Site Preparation Guide P/N: 300-012-149 Rev: A01

Copyright 2011 EMC Corporation. All rights reserved. EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED AS IS. EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com All other trademarks used herein are the property of their respective owners.

EMC Greenplum DCA Site Preparation Guide Contents EMC Greenplum DCA Site Preparation Guide - Contents Preface... 2 Chapter 1: About EMC Greenplum DCA... 3 Available DCA configurations... 3 GP10 (Quarter-Rack Configuration)... 5 GP100 (Half-Rack Configuration)... 6 GP1000 (One-Rack Configuration)... 7 GP1000 +1 Scale-out Module (Two-Rack Configuration)... 8 Component Specifications... 8 Chapter 2: Preparing the Data Center Environment...12 Confirming Site Requirements...12 Floor Space Requirements...12 Power and Cooling Requirements...12 Power Cord Specifications...13 Enviromental Requirements...14 Air Quality Requirements...14 Optional Securing Brackets...15 Anti-Tip Bracket...16 Anti-Move Bracket...16 Seismic Restraint Bracket...17 Cabinet Positioning...18 Package Dimensions and Clearance...19 Chapter 3: Gathering Site-Specific Information...20 Chapter 4: Next Steps...22 Table of Contents 1

EMC Greenplum DCA Site Preparation Guide Preface Preface This guide is intended for EMC personnel, partners and customers to plan for requirements before an installation of a new EMC Greenplum Data Computing Appliance (DCA) into a data center. This guide provides an overview of the system, information on data center requirements, a checklist of items to gather for software configuration and links to relevant documentation for use in the next steps of deployment. The requirements listed in this document must be met prior to performing a DCA installation. This guide contains the following chapters and appendices: Chapter 1, About EMC Greenplum DCA Chapter 2, Preparing the Data Center Environment Chapter 3, Gathering Site-Specific Information Chapter 4, Next Steps 2

Greenplum DCA Site Preparation Guide Chapter 1: About EMC Greenplum DCA 1. About EMC Greenplum DCA Greenplum Data Computing Appliance (DCA) is a self-contained data warehouse solution that integrates all of the database software, servers and switches necessary to perform big data analytics. EMC Greenplum Data Computing Appliance (DCA) is a turn-key, easy to install data warehouse solution that provides extreme query and loading performance for analyzing large data sets. The EMC Greenplum DCA integrates Greenplum Database software with compute, storage and network components; delivered racked and ready for immediate data loading and query execution. EMC Greenplum Data Computing Appliance runs the Greenplum Database relational database management system (RDBMS) software. Greenplum Database utilizes the DCA components to perform its database operations and processing. See the following sections for a description of the DCA components and configurations. Available DCA configurations Component Specifications Available DCA configurations This section details the rack configurations currently available for the DCA. Note that in the Greenplum Database product and documentation, physical servers are referred to as hosts. The GP10, GP100 and GP1000 have the same basic rack configuration, except for the number of segment hosts. Table 1.1 DCA Components DCA Component Master Hosts Quantity 2 (one primary and one standby) Segment Hosts GP10 (quarter-rack) = 4 GP100 (half-rack) = 8 GP1000 (one-rack) = 16 Interconnect Switches 2 Administration Switch 1 Available DCA configurations 3

Greenplum DCA Site Preparation Guide Chapter 1: About EMC Greenplum DCA A GP1000 scale-out module (two-rack configuration) contains all of the components of the GP1000 minus the master hosts. Table 1.2 DCA GP1000 Scale-Out Module Components DCA Component Segment Hosts Interconnect Switches Administration Switch Quantity 16 per rack 2 per rack 1 per rack Available DCA configurations 4

Greenplum DCA Site Preparation Guide Chapter 1: About EMC Greenplum DCA GP10 (Quarter-Rack Configuration) Figure 1.1 GP10 quarter-rack configuration Available DCA configurations 5

Greenplum DCA Site Preparation Guide Chapter 1: About EMC Greenplum DCA GP100 (Half-Rack Configuration) Figure 1.2 GP100 half-rack configuration Available DCA configurations 6

Greenplum DCA Site Preparation Guide Chapter 1: About EMC Greenplum DCA GP1000 (One-Rack Configuration) Figure 1.3 GP1000 one-rack configuration Available DCA configurations 7

Greenplum DCA Site Preparation Guide Chapter 1: About EMC Greenplum DCA GP1000 +1 Scale-out Module (Two-Rack Configuration) Figure 1.4 GP1000 plus 1 scale-out module (two-rack configuration) Component Specifications This section explains the specifications of the various server and networking components of the DCA. Note that in the Greenplum Database product and Component Specifications 8

Greenplum DCA Site Preparation Guide Chapter 1: About EMC Greenplum DCA documentation, physical servers are referred to as hosts. Table 1.3 DCA Components DCA Component Master Hosts Quantity All Configurations = 2 (one primary and one standby) Segment Hosts GP10 = 4 GP100 = 8 GP1000 = 16 GP1000+1 = 32 Interconnect Switches GP100/GP1000 = 2 GP1000+1 = 4 Administration Switch GP100/GP1000 = 1 GP1000+1 = 2 Master Host Specifications The following diagram shows an example of how a Greenplum Database master host is configured in the DCA. DCA has two master hosts (the primary master and a standby master). Figure 1.5 Greenplum Database Master Host Configuration on the DCA Component Specifications 9

Greenplum DCA Site Preparation Guide Chapter 1: About EMC Greenplum DCA Table 1.4 Master Host Server Specifications Hardware Specifications Quantity Processor Intel X5680 3.33 GHz (6 core) 2 Memory DDR3 1333 MHz 48 GB Dual-port Converged Network Adapter 2 x 10 Gbps 1 Quad-port Network Adapter 4 x 1 Gbps 1 RAID controller Dual channel 6 Gb/s SAS 1 Hard Disks 600 GB 10 K RPM SAS (one RAID5 volume of 4+1 with 1 hot spare) 6 Segment Host Specifications The following diagram shows an example of how a Greenplum Database segment host is configured in the DCA. Greenplum GP100 (half-rack) has 8 segment hosts. Greenplum GP1000 (full-rack) has 16 segment hosts. Each segment host serves 6 Greenplum Database primary segment instances and 6 mirror segment instances. Figure 1.6 Greenplum Database Segment Host Configuration on the DCA Component Specifications 10

Greenplum DCA Site Preparation Guide Chapter 1: About EMC Greenplum DCA Table 1.5 Segment Host Server Specifications Hardware Specifications Quantity Processor Intel X5670 2.93 GHz (6 core) 2 Memory DDR3 1333 MHz 48 GB Dual-port Converged Network Adapter 2 x 10 Gbps 1 Dual-port Network Adapter 2 x 1 Gbps 1 RAID controller Dual channel 6 Gb/s SAS 1 Hard Disks 600 GB 15 K RPM SAS (two RAID5 volumes of 5+1 disks) 12 Network Component Specifications Hardware Specifications Quantity Interconnect Switch 24-port Converged Enhanced Ethernet (CEE), Fibre Channel over Ethernet (FCoE) 8 Fibre Channel Ports (future use) 2 Admin Switch 24-port 1 Gb Ethernet Layer 3 1 11

Greenplum DCA Site Preparation Guide Chapter 2: Preparing the Data Center Environment 2. Preparing the Data Center Environment Confirming Site Requirements Optional Securing Brackets Cabinet Positioning Package Dimensions and Clearance Confirming Site Requirements The section summarizes the site requirements for the DCA. Floor Space Requirements Power and Cooling Requirements Power Cord Specifications Enviromental Requirements Air Quality Requirements Floor Space Requirements The following table describes the physical footprint of the DCA: Table 2.1 DCA Physical Dimensions Height Width Depth 1 Weight GP10 (quarter-rack) 75 in 190 cm 24 in 61 cm 41.6 in 104 cm 940 lbs GP100 (half-rack) 75 in 190 cm 24 in 61 cm 41.6 in 104 cm 1200 lbs GP1000 (one-rack) 75 in 190 cm 24 in 61 cm 41.6 in 104 cm 1700 lbs GP1000+1(two-rack) 75in 190 cm 48 in 122 cm 41.6 in 104 cm 3400 lbs 1. with door attached Power and Cooling Requirements The following table describes the power and cooling requirements of the DCA: Table 2.2 EMC Greenplum Data Computing Appliance Physical Dimensions Total Power VA Power Connections Cooling (BTU/HR) GP10 (quarter-rack) 2478 2 8450 Confirming Site Requirements 12

Greenplum DCA Site Preparation Guide Chapter 2: Preparing the Data Center Environment Table 2.2 EMC Greenplum Data Computing Appliance Physical Dimensions GP100 (half-rack) 3980 2 13600 GP1000 (one-rack) 6980 4 23800 GP1000+1(two-rack) 13960 8 47600 Power Cord Specifications Table 2.3 Power Cord Specifications Power Cord Connector Country USA, Japan Power Cord Model Descriptions DCA1-US-15 DCA - Single Phase, 30Amp, 15ft ext cords with L6-30P plug DCA1-US-21 DCA - Single Phase, 30Amp, 21ft ext cords with L6-30P plug Australia DCA1-ASTL-15 DCA - Single Phase, 30Amp, 15ft ext cords with CLIPSAL 56PA332 plug DCA1-ASTL-21 DCA - Single Phase, 30Amp, 21ft ext cords with CLIPSAL 56PA332 plug Other Countries DCA1-IEC3-15 DCA - Single Phase, 30Amp, 15ft ext cords with IEC309-332P6 plug DCA1-IEC3-21 DCA - Single Phase, 30Amp, 21ft ext cords with IEC309-332P6 plug Other Power Cord Types DCA1-RUS-15 DCA - Single Phase, 30Amp, 15ft ext cords with RUSSELLSTOLL 3750DP plug DCA1-RUS-21 DCA - Single Phase, 30Amp, 21ft ext cords with RUSSELLSTOLL 3750DP plug Confirming Site Requirements 13

Greenplum DCA Site Preparation Guide Chapter 2: Preparing the Data Center Environment Enviromental Requirements Table 2.4 Environmental Requirements +15 C to +32 C (59 F to 89.6 F) site temperature 40% to 55% relative humidity 0 to 2439 meters (0 to 8,000 feet) above sea level operating altitude Air Quality Requirements EMC products are designed to be consistent with the requirements of the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) Environmental Standard Handbook and the most current revision of Thermal Guidelines for Data Processing Environments, Second Edition, ASHRAE 2009b. The data center should maintain a cleanliness level as identified in ISO 14664-1, class 8 for particulate dust and pollution control. The air entering the data center should be filtered with a MERV 11 filter or better. The air within the data center should be continuously filtered with a MERV 8 or better filtration system. In addition, efforts should be maintained to prevent conductive particles, such as zinc whiskers, from entering the facility. The allowable relative humidity level is 20 to 80% non condensing, however, the recommended operating environment range is 40 to 55%. For data centers with gaseous contamination, such as high sulfur content, lower temperatures and humidity are recommended to minimize the risk of hardware corrosion and degradation. In general, the humidity fluctuations within the data center should be minimized. It is also recommended that the data center be positively pressured and have air curtains on entry ways to prevent outside air contaminants and humidity from entering the facility. For facilities below 40% relative humidity, it is recommended to use grounding straps when contacting the equipment to avoid the risk of Electrostatic discharge (ESD), which can harm electronic equipment. As part of an ongoing monitoring process for the corrosiveness of the environment, it is recommended to place copper and silver coupons (per ISA 71.04-1985, Section 6.1 Reactivity), in airstreams representative of those in the data center. The monthly reactivity rate of the coupons should be less than 300 Angstroms. When monitored reactivity rate is exceeded, the coupon should be analyzed for material species and a corrective mitigation process put in place. Confirming Site Requirements 14

Greenplum DCA Site Preparation Guide Chapter 2: Preparing the Data Center Environment This EMC cabinet ventilates from front to back; you must provide adequate clearance to service and cool the system. Depending on component-specific connections within the cabinet, the available power cord length may be somewhat shorter than the 15-foot standard. Figure 2.1 Access and Ventilation Requirements Optional Securing Brackets If you intend to secure the optional stabilizer brackets to your site floor, prepare the location for the mounting bolts. The additional brackets help to prevent the cabinet from tipping while you service cantilevered levels, or from rolling during minor seismic events. The brackets provide three levels of protection for stabilizing the unit. Anti-Tip Bracket Anti-Move Bracket Seismic Restraint Bracket Optional Securing Brackets 15

Greenplum DCA Site Preparation Guide Chapter 2: Preparing the Data Center Environment Anti-Tip Bracket Use this bracket to provide an extra measure of anti-tip security. One or two kits may be used. For cabinets with components that slide, EMC recommends that you use two kits. Figure 2.2 Anti-Tip Bracket Placement Anti-Move Bracket Use this bracket to permanently fasten the unit to the floor. Figure 2.3 Anti-Move Bracket Placement Optional Securing Brackets 16

Greenplum DCA Site Preparation Guide Chapter 2: Preparing the Data Center Environment Seismic Restraint Bracket Use this bracket to provide the highest protection from moving or tipping. Figure 2.4 Seismic Restraint Bracket Placement Optional Securing Brackets 17

Greenplum DCA Site Preparation Guide Chapter 2: Preparing the Data Center Environment Cabinet Positioning The cabinet bottom includes four caster wheels. The front wheels are fixed; the two rear casters swivel in a 1.75-inch diameter. Swivel position of the caster wheels will determine the load-bearing points on your site floor, but does not affect the cabinet footprint. Once you have positioned, leveled, and stabilized the cabinet, the four leveling feet determine the final load-bearing points on your site floor. Figure 2.5 Cabinet Positioning When the cabinet is centered over two typical 24 in. (60.96 cm) by 24 in. (60.96 cm) floor tiles: Cutouts should be 8 in. (20.32 cm) by 6 in. (15.24 cm). Cutouts should be centered on the tiles, 9 in. (22.86 cm) from the front and rear and 8 in. (20.32 cm) from sides. Cabinet Positioning 18

Greenplum DCA Site Preparation Guide Chapter 2: Preparing the Data Center Environment Package Dimensions and Clearance Make certain your doorways and elevators are wide enough and tall enough to accommodate the shipping pallet and cabinet. Use a mechanical lift or pallet jack to position the packaged cabinet in its final location. Figure 2.6 Door Clearance Leave approximately 2.43 meters (8 feet) of clearance at the back of the cabinet to unload the unit and roll it off the pallet. Figure 2.7 Unloading Clearance Package Dimensions and Clearance 19

Greenplum DCA Site Preparation Guide Chapter 3: Gathering Site-Specific Information 3. Gathering Site-Specific Information In order to complete an installation of an EMC Greenplum DCA, the following information should be gathered from the customer s network and database personnel: Table 3.1 Site-Specific Information Information External IP and hostname of the primary master External IP and hostname of the standby master Netmask Gateway NTP server IP DNS name server IP idrac password root password gpadmin password System locale System timezone Description This is the IP address and hostname that the customer will use to connect to the primary master host from their public LAN. The master hostname is also used for client connections to Greenplum Database. This is the IP address and hostname that the customer will use to connect to the standby master host from their public LAN. Netmask of the customer s network. Default gateway of the customer s network and the IP address and interface name of the router. The IP address or hostname of the customer s preferred NTP (Network Time Protocol) server. The IP address of the customer s DNS name server. This is the password used for remote access to the master, standby master and segment hosts using the integrated Dell Remote Access Controller (idrac) interface. The default idrac password is calvin. Customer supplied root password for the master, standby master and segment hosts. The default root password is changeme. Customer supplied Greenplum Database superuser password. The default gpadmin password is changeme. The preferred locale to be used on the master, standby master and segment hosts. en_us.utf-8 is the default locale for the Greenplum DCA (U.S. English and Unicode character set encoding). A locale identifier consists of a language identifier and a region identifier, and optionally a character set encoding. For example, sv_se is Swedish as spoken in Sweden, en_us is U.S. English, and fr_ca is French Canadian. If more than one character set encoding can be useful for a locale, then the specifications look like this: en_us.utf-8 (locale specification and character set encoding). The local timezone to be used on the master, standby master and segment hosts. The default timezone is PST. 20

Greenplum DCA Site Preparation Guide Chapter 3: Gathering Site-Specific Information Table 3.1 Site-Specific Information Information Database character set encoding Software Tools Hardware Tools Description UNICODE (UTF-8) is the default character set encoding for Greenplum Database (server-side encoding). This is usually the best choice, as it allows the customer to store all possible Unicode characters from any language, but if all data you are storing is from a single language (now and in the future), it does entail a slight storage space penalty compared to an encoding specific to that language. If the space savings is key, the customer should consider Latin-1, Latin-9, or WIN1252 for US or Western European installations, since those encodings use a single byte per character. Likewise in Thailand you might consider WIN874 to store Thai, since it uses a single byte per character. However, keep in mind that this prevents storing any data outside those character sets. Even in the US or Western Europe, customers might find that some of their data is Latin-1, while some is Latin-9 or Win1252, so any choice of single-byte encoding will not accommodate all of their data needs. See the Greenplum Database Administrator Guide for a list of all supported character set encodings. Connection to the DCA for setup and management requires an SSH utility. EMC recommends Putty or Cygwin. The following hardware tools will be required during installation of the DCA: Utility Knife 9/16 Socket Wrench ESD (electro-static discharge) kit Power Connection for Service Laptop Dial-home Connectivity Power for external devices should not be drawn from the DCA cabinet. A power connection is required for the EMC personnel service laptop. The connection should be a standard AC 100-240V~1.5A, 50-60hz outlet. The DCA supports dial-home for event notification to EMC Global Services support center. Communication from the DCA to EMC is done via FTPS. Firewall access should be setup to allow FTPS traffic from the DCA s external IP address to the following EMC addresses: corpusfep3.emc.com corpusfep4.emc.com 21

Greenplum DCA Site Preparation Guide Next Steps: 4. Next Steps The following documentation may be used during the next steps in implementing your Data Computing Appliance: EMC Greenplum Data Computing Appliance Getting Started Guide http://powerlink.emc.com/km/live1/en_us/offering_technical/technical_d ocumentation/300-011-454.pdf Greenplum Database 4.0 Administrator Guide http://powerlink.emc.com/km/live1/en_us/offering_technical/technical_d ocumentation/300-011-538.pdf Greenplum Database 4.0 Release Notes http://powerlink.emc.com/km/live1/en_us/offering_technical/technical_d ocumentation/300-011-650.pdf 22