Accessories and Spare Parts

Size: px
Start display at page:

Download "Accessories and Spare Parts"

Transcription

1 For T Contactors and Contactor Relays Accessories for TB, TC, TF, TG, TK contactors Size Type kg Solid-state compatible auxiliary switch blocks with screw terminals 5TY and 4 TF68 For mounting onto the side of and contactors. TF69 For use in dusty atmosphere and solidstate circuits with rated operating TC44... TC48 currents I e /AC-14 and DC-1 from 1 ma to 00 ma at V to 60 V. With 1 changeover contact. 2nd auxiliary switch block, left or right (replacement for TY U, TY V) B TY UA unit Coupling links for control by PLC 14 TF68 and TF69 Operating range: 17 to 0 V DC. Power consumption: 0.5 W at 24 V DC. Fitted with varistor. For technical specifications, see LV 1 T For snapping onto the side of auxiliary switch, with surge suppression } TX D 1 1 unit Terminal covers for protection against inadvertent contact with exposed bar connections 14 TF68 For screwing onto free screw end on B TX A 1 1 set TF69 middle connecting bar. 2 units required per contactor. B TX A 1 1 set (1 set = 2 units) TX7 6 TB50, TC48 8 and SIRIUS S6 TB52 RT1.5 1) The link for paralleling can be reduced by one pole. Can be screwed on free screw end. Covers one rail connection (1 set = 6 units). M 6 B TX6 506-B 1 1 set M 8 B TX6 526-B 1 1 set and TB54... M 10 B TX6 546-B 1 1 set TX6 526-B 14 and TB56, SIRIUS TC52, S10, S12 TC56 RT1.6 RT1.7 Links for paralleling (star jumper) ¼ -pole, without connection terminal 1) 14 TF68 C TX D 1 1 unit Cover plate for link for paralleling 14 TF68 A cover plate must be used in order to protect against inadvertent contact with exposed bar connections (EN 50274). C TX E 1 1 unit Box terminals for laminated copper bars Without auxiliary conductor connection (1 set = units) 14 TF68 With single covers for protection against inadvertent contact (EN 50274) With auxiliary conductor connection (1 set = units) 14 TF68 With single covers for protection against inadvertent contact (EN 50274) 14 TF69 Conductor cross-sections for auxiliary conductors: Solid 2 x ( ) mm 2 Finely stranded with end sleeve 2 x ( ) mm 2 Solid or stranded 2 x ( ) AWG Tightening torque Nm ( lb.in) C TX E 1 1 set C TX F 1 1 set C TX F 1 1 set Siemens LV /15

2 For T Contactors and Contactor Relays Accessories for TB, TC, TF, TG, TK contactors Remarks Rated control supply voltage U s Size Type V DC kg 2 TC L.. With cutout for B TY B 1 1 unit mounting resistor 2 TC44 With series resistor Without varistor 24 C TY6 44-0LB4 1 1 unit C TY6 44-0LF4 1 1 unit TC48 24 C TY6 48-0LB4 1 1 unit C TY6 48-0LF4 1 1 unit TB50 24 C TY6 50-0LB4 1 1 unit C TY6 50-0LF4 1 1 unit TB52 and TC52 24 C TY6 52-0LB4 1 1 unit C TY6 52-0LF4 1 1 unit TB54 24 C TY6 54-0LB4 1 1 unit C TY6 54-0LF4 1 1 unit TB56 and TC56 24 C TY6 56-0LB4 1 1 unit C TY6 56-0LF4 1 1 unit All spare parts not mentioned above are identical to those for the standard contactors. Auxiliary contacts Rated operating current I e /AC-15/AC-14 at 20/ 220 V 400/ 80 V 500 V AC Auxiliary contacts Ident. No. Number A A A N O Snap-on auxiliary switch blocks for TF2 contactors ¼ with screw terminals TX A N C N N O C For assembling contactors with several auxiliary contacts With 2, 4 and 5 auxiliary contacts according to DIN For TF2. 10 contactors (auxiliary contact 1 NO = 10E) E B TX A 1 1 unit E B TX A 1 1 unit E B TX4 41-1A 1 1 unit E B TX A 1 1 unit With and 5 auxiliary contacts according to DIN for TF2 contactors B TX A 1 1 unit B TX A 1 1 unit B TX A 1 1 unit ; U B TX G 1 1 unit B TX A 1 1 unit B TX4 41-2A 1 1 unit B TX A 1 1 unit ; 2 U B TX G 1 1 unit kg Rated control supply voltage U s Time range (minimum times) Type OFF-delay devices (with screw terminals) for TF2 contactors For DC-operated contactors for bridging short-time power failures up to 0.8 s TF2...-0BB4 24 V DC 0.25 s or 0.5 s PU PS* PG Weight kg B TX H 1 1 unit /16 Siemens LV

3 For T Contactors and Contactor Relays Accessories for TH contactor relays Rated control supply voltage U s OFF delay AC DC 50/60 Hz Type V V s kg OFF-delay devices for bridging short-time power failures (up to 1.2 s) TH42..-0BF or 0. A TX AN1 1 1 unit TH4..-0BF4 TH42..-0BM or 1.2 A TX AN1 1 1 unit TH4..-0BM4 TH42..-0BP4 TH4..-0BP or 1.2 A TX AN1 1 1 unit TH42..-0BB or 0.8 A TX BB4 1 1 unit TX AN1 TH4..-0BB4 Contacts Rated operating current I e /AC-15/AC-14 at 20/ 400/ 500 V 690/ Ident. No. 220 V 80 V AC 660 V acc. to EN Contacts Number A A A A NO NC NO NC kg Snap-on auxiliary switch blocks for TH20 contactor relays ¼ with screw terminals With 8 contacts according to EN 50011, For snapping onto contactor relays with 4 NO, Ident. No. 40E (TH ) E B TX A 1 1 unit E B TX4 41-0A 1 1 unit TX A 62 E B TX A 1 1 unit E B TX4 41-0A 1 1 unit E B TX A 1 1 unit With 6 and 8 contacts according to EN E B TX A 1 1 unit E B TX4 41-2A 1 1 unit E B TX A 1 1 unit ; 2U B TX G 1 1 unit E B TX A 1 1 unit E B TX A 1 1 unit E B TX A 1 1 unit ; U B TX G 1 1 unit Type OFF-delay devices (with screw terminals) TX A Rated control supply voltage U s Time range (minimum times) PU PS* PG Weight kg For DC-operated contactors for bridging short-time power failures up to 0.8 s TH2...-0BB4 24 V DC 0.25 s or 0.5 s B TX H 1 1 unit TH2...-0BF4 110 V AC, 50/60 Hz 0.1 s or 0.2 s B TX A 1 1 unit TH2...-0BM4, TH2...-0BP4 220 V AC, 50/60 Hz 0.4 s or 0.8 s /140 Siemens LV

4 For T Contactors and Contactor Relays Spare parts for TB, TC, TF, TK contactors Selection and ordering data Contacts Size Type NO NC NC kg 6 TB Auxiliary switch B TY AA unit block, left or right (replacement for TY A/-1B) Auxiliary switch C TY E 1 1 unit block, right TB Auxiliary switch B TY A 1 1 unit TB block, left Auxiliary switch block, right B TY B 1 1 unit TY A Auxiliary switch C TY E 1 1 unit block, right DC operation 6 TB50 C TY6 50-0B unit TB52 C TY6 52-0B unit TB54 C TY6 54-0B unit TB56 C TY6 56-0B unit TY TB50 1 arc chute, -pole B TY A 1 1 unit TB52 C TY A 1 1 unit TB54 C TY A 1 1 unit TB56 C TY A 1 1 unit TY A Contacts with fixing parts In order to ensure reliable operation of the contactors, only original replacement contacts from Siemens should be used. 6 TB50 (1 set = moving and B TY A 1 1 set TB52 6 fixed contacts) B TY A 1 1 unit TB54 B TY A 1 1 set TB56 B TY A 1 1 set TY A For rated control supply voltages for coils, see page /146. /142 Siemens LV

5 For T Contactors and Contactor Relays Spare parts for TB, TC, TF, TK contactors For contactor Auxiliary contacts Size Type NO NC kg 2 and 4 TB44, TC Auxiliary switch block, left or right (replacement for TY A/-1B) B TY AA unit TC nd auxiliary switch block, left 1) C TY K 1 1 unit nd auxiliary switch block, C TY L 1 1 unit right 1) 8 and 12 TC52, 1 1 Auxiliary switch block, left B TY A 1 1 unit TC56 Auxiliary switch block, B TY B 1 1 unit TY A right 2nd auxiliary switch block, C TY K 1 1 unit left 1) 2nd auxiliary switch block, C TY L 1 1 unit right 1) Contacts with fixing parts In order to ensure reliable operation of the contactors, only original replacement contacts from Siemens should be used. 2 TC44 (1 set = 2 moving and 2 fixed switching B TY A 1 1 set TC48 elements) B TY A 1 1 set TC52 B TY A 1 1 set TY A 12 TC56 B TY A 1 1 set Rated control supply voltages for coils, see page / TC44 1 arc chute, C TY A 1 1 unit TC48 2-pole C TY A 1 1 unit TC52 C TY A 1 1 unit TC56 C TY A 1 1 unit TC2 48 DC operation 2 TC44 C TY6 44-0B unit TC48 C TY6 48-0B unit TC52 C TY6 52-0B unit TC56 C TY6 56-0B unit AC operation 2 TC44 C TY7 40-0A unit TC48 C TY6 48-0A unit TC52 C TY6 52-0A unit TC56 C TY A unit ) Can only be mounted on AC-operated contactors. Siemens LV /14

6 For T Contactors and Contactor Relays Spare parts for TB, TC, TF, TK contactors Varistors For contactor Rated control supply voltage U s PU PS* PG Weight Type V AC/DC kg TC7 Contacts with fixing parts TC7 For sticking onto the contactor base Main contacts (1 set) For TC78: 2 units required per contactor 24 C TX F 1 1 unit C TX G 1 1 unit B TY E 1 1 set TC74 4 NO +4 NC B TY J 1 1 unit TC78 Auxiliary contact, left, with C TY C 1 1 unit NO +2 NC Auxiliary contact, right, with 2 NO +2 NC C TY D 1 1 unit TC7 For TC78: 2 units required per contactor C TY C 1 1 unit Contacts Size Type NO NC NC kg With screw terminals TY TF68 and TF st auxiliary switch block, left or right Replacement for: TY A/-1B Auxiliary switch block, left or right nd auxiliary switch block, left or right Replacement for: TY K/-1L. For coil reconnection with DC economy circuit, with screw terminals 14 TF68 and TF69 B TY AA unit B TY EA unit B TY KA unit Auxiliary contact block C TY G 1 1 unit For rated control supply voltages for coils, see page /146. Size Type kg AC operation 14 TF68 The coils are fitted as standard with C TY7 68-0C unit TF69 varistors against overvoltage. The coil is C TY7 69-0C unit supplied with switch-on electronics. DC operation DC economy circuit 14 TF68 Reversing contactors are required for C TY7 68-0D unit TF69 size 14 contactors: Contactor type TF68 and TF69 Reversing contactor TC44 (70 mm wide, 85 mm high) The coils are supplied without reversing C TY7 69-0D unit TY7. contactor. Vacuum interrupters In order to ensure reliable operation of the contactors, only original replacement interrupters from Siemens should be used. 14 TF68 vacuum interrupters with mounting B TY B 1 1 set TF69 parts B TY B 1 1 set For solid-state compatible auxiliary switch blocks, see page /15. /144 Siemens LV

Suppressors for contactors

Suppressors for contactors A safe, unshakeable connection is an important criteria for all suppressors Snaps into the label plate opening The label plate of the contactor can be removed and our suppressor module snaps firmly in

More information

Siemens AG SB3 Pushbuttons and Indicator Lights, 22 mm. Application. 7 ASIsafe EMERGENCY-STOP mushroom pushbuttons (see page 9/64)

Siemens AG SB3 Pushbuttons and Indicator Lights, 22 mm. Application. 7 ASIsafe EMERGENCY-STOP mushroom pushbuttons (see page 9/64) General data Design The 3SB3 series is a modular range of commanding and signaling devices for front panel mounting and rear conductor connection. As an alternative, individual elements can also be supplied

More information

13. Manufacturer's warranty Marking 6 W A R N I N G!

13. Manufacturer's warranty Marking 6 W A R N I N G! CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and instalation 3 8. Dimensions 5 9. Inspection,

More information

Rail Clamps Type BSZ. PINTSCH BUBENZER is certified according to DIN EN ISO 9001:2008. Safe Tried and Trusted High Performance Robust Easy Maintenance

Rail Clamps Type BSZ. PINTSCH BUBENZER is certified according to DIN EN ISO 9001:2008. Safe Tried and Trusted High Performance Robust Easy Maintenance Rail Clamps Type BSZ PINTSCH BUBENZER is certified according to DIN EN ISO 0:0 Safe Tried and Trusted High Performance Robust Easy Maintenance H Description BSZ Main Features Rail clamp spring applied

More information

Protection of Power Conversion Equipment. PSC LR Fuses Thermal Management

Protection of Power Conversion Equipment. PSC LR Fuses Thermal Management Protection of Power onversion quipment PS L Fuses Thermal Management PS - L range Semiconductor Fuses Large rectifier PS fuse selection 25 UD 123 TTF 630 4 UD TDF 1000 9,5 UD 94 PPSF 3800 + M3 1-5N Ferraz

More information

QM35. Cover. Output. A = Line Driver B = Line Driver (ABZ) /Open Collector (UVW) C = Dual Votage Line Driver (ABZ)/ Open Collector (UVW)

QM35. Cover. Output. A = Line Driver B = Line Driver (ABZ) /Open Collector (UVW) C = Dual Votage Line Driver (ABZ)/ Open Collector (UVW) QM35 DESIGN FEATURES Bearingless modular design Low profile assembled height Resolutions up to 8192 lines per revolution 4, 6, 8 or 10 pole commutation Easy lock-n-twist assembly feature Through shaft

More information

QML35. Cover. Voltage A = 5V (+/- 5%) B = 3.3V (+/- 5%)

QML35. Cover. Voltage A = 5V (+/- 5%) B = 3.3V (+/- 5%) QML35 DESIGN FEATURES Bearingless modular design Low profile assembled height Resolutions up to 8192 lines per revolution 4, 6, 8 or 10 pole commutation Easy lock-n-twist assembly feature Through shaft

More information

2001 7½-Digit High Performance Multimeter ½-Digit High Performance Multimeter

2001 7½-Digit High Performance Multimeter ½-Digit High Performance Multimeter True 7½- (Model 2001) or 8½-digit (Model ) resolution Exceptional measurement integrity with high speed High speed function and range changing Broad range of built-in measurement functions Multiple measurement

More information

2001 7½-Digit High Performance Multimeter ½-Digit High Performance Multimeter

2001 7½-Digit High Performance Multimeter ½-Digit High Performance Multimeter DMM users whose applications demand exceptional resolution, accuracy, and sensitivity combined with high throughput now have two attractive alternatives to high priced, high end DMMs. Keithley s 7½-digit

More information

DIN ISO 9001 : 2000 QA-Nr.: Safe Tried and Trusted High Performance Robust Easy Maintenance

DIN ISO 9001 : 2000 QA-Nr.: Safe Tried and Trusted High Performance Robust Easy Maintenance Rail Clamps Type BSZ DIN ISO 0 : 00 QA-Nr.: 0400 924 BUBENZER BREMSEN is certified according to DIN EN ISO 0:00 Safe Tried and Trusted igh Performance Robust Easy Maintenance Description BSZ Main Features

More information

An Extensive Selection of Fiber-Optic Cables E32. Fiber-Optic Sensing Heads Offer a Wide Variety of Unique Solutions for Tough Problems

An Extensive Selection of Fiber-Optic Cables E32. Fiber-Optic Sensing Heads Offer a Wide Variety of Unique Solutions for Tough Problems R An Extensive Selection of Fiber-Optic Cables Fiber-Optic Sensing Heads Offer a Wide Variety of Unique Solutions for Tough Problems H Fiber-optic sensors detect small, fast-moving objects in space-confined

More information

Heavy Engineering Corporation Limited (A Govt. of India Enterprise) Heavy Machine Building Plant MM DIVISION

Heavy Engineering Corporation Limited (A Govt. of India Enterprise) Heavy Machine Building Plant MM DIVISION HMB/PUR/0/035/07/EL(Crane)-535 Dtd 7..7 To, M/s Siemens Ltd. Industry Customer Service DF Roshan Tower, nd floor S.B. Shop, Bistupur Jamshedpur-8300 (Jharkhand) We request you to submit your most competitive

More information

Xantrex Complete Charge Controller Supplemental Owner s Manual Rev 1.0 Copyright 2012

Xantrex Complete Charge Controller Supplemental Owner s Manual Rev 1.0 Copyright 2012 Xantrex Complete Charge Controller Supplemental Owner s Manual Rev 1.0 Copyright 2012 1 Table of Contents Introduction 3 Main Components of the Xantrex Complete Charge Controller 3 Mounting the Xantrex

More information

January 30, ABB to acquire Thomas & Betts Unlocking the North American Low- Voltage Market

January 30, ABB to acquire Thomas & Betts Unlocking the North American Low- Voltage Market January 30, 2012 ABB to acquire Thomas & Betts Unlocking the North American Low- Voltage Market Safe-harbor statement This presentation contains "forward-looking statements" relating to the proposed acquisition

More information

RUGGEDCOM Modules. Preface. Introduction 1. Power Supply Modules 2. Copper Ethernet Modules 3. Fiber Optic Ethernet Modules 4

RUGGEDCOM Modules. Preface. Introduction 1. Power Supply Modules 2. Copper Ethernet Modules 3. Fiber Optic Ethernet Modules 4 Preface Introduction 1 RUGGEDCOM Modules Power Supply Modules 2 Copper Ethernet Modules 3 Fiber Optic Ethernet Modules 4 Precision Time Protocol (PTP) Modules 5 Blank Modules 6 For RSG2488, RSG2488F 10/2018

More information

SR120MP. Dual-Channel Multi-Purpose Safety Monitoring Relay. Specifications. Safety Monitoring Relays

SR120MP. Dual-Channel Multi-Purpose Safety Monitoring Relay. Specifications. Safety Monitoring Relays R Safety Monitoring Relays Dual-Channel Multi-Purpose Safety Monitoring Relay Power requirements the will accept 24 VAC/DC or 110 VAC Inputs the provides dual-channel input from a variety of safety devices.

More information

The MICROS Bump Bar MBB-10 and MBB-20 User s Guide

The MICROS Bump Bar MBB-10 and MBB-20 User s Guide The MICROS Bump Bar MBB-10 and MBB-20 User s Guide This document describes the MBB features, shows how to adjust the speaker and LED from the keypad, as well as determine the firmware version and how to

More information

Xantrex XW Hybrid Inverter/Charger

Xantrex XW Hybrid Inverter/Charger Xantrex XW Hybrid Inverter/Charger Xantrex XW4024 230 50 Xantrex XW4548 230 50 Xantrex XW6048 230 50 Installation Guide www.schneider-electric.com YOUR SCHNEIDER ELECTRIC DISTRIBUTOR SOLIGENT 800-967-6917

More information

AC Line Rated Ceramic Disc Capacitors Class X1, 400 V AC / Class Y4, 125 V AC

AC Line Rated Ceramic Disc Capacitors Class X1, 400 V AC / Class Y4, 125 V AC AC Line Rated Ceramic Disc Capacitors Class X1, V AC / Class Y4, 125 V AC FEATURES Complying with IEC 6384-14 3 rd edition High reliability Complete range of capacitance values Radial leads Singlelayer

More information

Type Approval Certificate

Type Approval Certificate Type Approval Certificate This is to certify that the undernoted product(s) has/have been tested with satisfactory results in accordance with the relevant requirements of the Lloyd s Register Type Approval

More information

Must Operate Voltage (V) 24 VDC % max. 10% min. 110% Approx. 0.8

Must Operate Voltage (V) 24 VDC % max. 10% min. 110% Approx. 0.8 Force-Guided Relays G7S- -E Lineup Now Includes 10 A Models Relays with forcibly guided contacts (EN50205 Class A, certified by VDE). Supports the CE marking of machinery (Machinery Directive). Helps avoid

More information

2001 7½-Digit High Performance Multimeter ½-Digit High Performance Multimeter

2001 7½-Digit High Performance Multimeter ½-Digit High Performance Multimeter Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 2001 True 7½- (Model 2001) or 8½-digit (Model ) resolution Exceptional measurement integrity with high

More information

Parts List, Charging Chart, Wiring Diagrams

Parts List, Charging Chart, Wiring Diagrams Parts List, Charging Chart, Wiring Diagrams PAE090-150 SERIES PACKAGE AIR CONDITIONER UNITS TABLE OF CONTENTS PARTS LIST------------ 2-5 PARTS DRAWING - - - - - - 6-10 CHARGING CHARTS - - - 11-13 WIRING

More information

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC / Class Y1, 500 V AC

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC / Class Y1, 500 V AC 4L Series AC Line Rated Ceramic Disc Capacitors Class X, 76 V AC / Class Y, 5 V AC FEATURES Complies with IEC 6384-4, 4 th edition High reliability Radial leads High capacitance up to nf Singlelayer AC

More information

SR223SMT. Safety Module Timer Unit. Specifications. Safety Monitoring Relays

SR223SMT. Safety Module Timer Unit. Specifications. Safety Monitoring Relays R Safety Monitoring Relays Safety Module Timer Unit Power requirements the will accept 24 VAC/DC or 115 VAC Delayed outputs the has 1 N/O on-delay output, plus 2 N/C off-delay outputs (selectable from

More information

S800 PREPAID CARD TIMER

S800 PREPAID CARD TIMER Construction Characteristics: Number of conductors : 2 wires. Dielectric strength : 4KV. Type of register mechanism : LCD display. Display features : Backlit 16 character/7 segment display. Size of characters

More information

Q&A Distribution equipment and materials

Q&A Distribution equipment and materials Q&A Distribution equipment and materials ITB-223/17 Establishing Long Term Agreement (LTA) in Two Lots for purchasing various capacities Transformers and Electricity supplies under Funding Facility for

More information

18 STÖGRA panel mount/19 inch-systems series ELK/ELR

18 STÖGRA panel mount/19 inch-systems series ELK/ELR STÖGRA ANTRIEBSTECHNIK GMBH www.stoegra.de stepping motor controls catalogue 0 STÖGRA panel mount/9 inch-systems series ELK/ELR The panel mount / 9 inch rack system series ELK/ELR is a mains ready single

More information

High Breaking Capacity Miniature Circuit Breakers Hti Plus, Technical Manual

High Breaking Capacity Miniature Circuit Breakers Hti Plus, Technical Manual High Breaking Capacity Miniature Circuit Breakers Hti Plus, Technical Manual 1 Summary T1. Line Protection HTI PLUS. HIGH BREAKING CAPACITY MCBS. TECHNICAL MANUAL T1.1. Definitions related to MCB s T1.2.

More information

January 2018 PRICE SCHEDULE A 2.0 Advanced Replacement & Repair

January 2018 PRICE SCHEDULE A 2.0 Advanced Replacement & Repair Section A5 This Price Schedule is effective January 1, 2018. Date Page Comment 1-1-18 All January, 2018 Price Schedule update. 3-15-18 7 Updated 1881-010 decoder board for 1816 system. 3-19-18 13 Added

More information

Integral E-stop the lidmounted. emergency stopping capability at the extreme end of the installation. Status indicator the lidmounted

Integral E-stop the lidmounted. emergency stopping capability at the extreme end of the installation. Status indicator the lidmounted ev..0 C US Conforms to EN418, EN292, ISO/IEC1850, and EN0947-5-1 UL and C-UL listed, B approved safety interlock switches Combination ope and Push-Button Actuated Emergency Stop Switch Long rope spans

More information

Effective March 16, 2015

Effective March 16, 2015 Alberta Pricing and Schedule A Effective: March Code FG Resident Sportfishing $ 28.00 $ 29.40 $ 2.75 AA Resident Antelope Archery Draw $ 59.95 $ 62.95 $ 2.75 AC NRA Wildlife Certificate $ 68.22 $ 71.63

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 J. A. KING & COMPANY, LLC. 1712 12 th Avenue North Suite F Bessemer, AL 35020 Connie B. Foster Phone: 800 327 7727 CALIBRATION Valid To: May 31, 2019 Certificate

More information

Indicators M22N. Indicators with 22-mm Diameters. New Product

Indicators M22N. Indicators with 22-mm Diameters. New Product New Product Indicators M22N Indicators with 22-mm Diameters Easy to Use Terminal screw hold-on structure that is compatible with round crimp terminals. Product Lineup Global applicability with safety standards

More information

EXTENDED WARRANTY PROGRAM GUIDE. Qualifying Qualifying is easy. To participate, you must be registered with Factory Assurance Southwest ( FAS ).

EXTENDED WARRANTY PROGRAM GUIDE. Qualifying Qualifying is easy. To participate, you must be registered with Factory Assurance Southwest ( FAS ). FACTORY ASSURANCE SOUTHWEST Division of Factory Reps Southwest P.O. Box 64935, Lubbock, Texas 79464 Phone (806) 771-0019 Fax (806) 799-4375 www.fasouthwest.com EXTENDED WARRANTY PROGRAM GUIDE Qualifying

More information

MicroFIT-Generation Connection Application For Connection of Micro-Generation Facilities of 10 kw

MicroFIT-Generation Connection Application For Connection of Micro-Generation Facilities of 10 kw This application is applicable to individual or multiple generating units at the Applicant s facility with total nameplate rating of 10 kw or less. The applicant s generation facility must generate electricity

More information

Authority 1: EAC (Electricity Authority of Cyprus) as acting DSO, Technical Instruction KE1/33/2005

Authority 1: EAC (Electricity Authority of Cyprus) as acting DSO, Technical Instruction KE1/33/2005 A. INTERCONNECTION RULES Country: CYPRUS Eligible renewable /other technologies: PV Applicable sectors: All sectors Breakpoint for Small System (Simplified Rules): 20 kw Rules for net metering systems:

More information

Pump Controllers Industrial / Commercial / Municipal

Pump Controllers Industrial / Commercial / Municipal February 009 1-1 Product Description Eaton s Cutler-Hammer custom Pump Controllers are designed for use in a variety of Industrial, Commercial and Municipal pumping applications from simplex and duplex

More information

BID TABULATION INVITATION TO BID TRANSFORMER REPAIR/REMANUFACTURE

BID TABULATION INVITATION TO BID TRANSFORMER REPAIR/REMANUFACTURE BID TABULATION INVITATION TO BID 156-14 TRANSFORMER REPAIR/REMANUFACTURE T&R Electric 1. Bid prices for repair/reconditioning of single-phase, 7620/13200 pole-mount, conventional transformers, as follows:

More information

182. PROFILE ON THE PRODUCTION OF PRINTED CIRCUIT BOARD

182. PROFILE ON THE PRODUCTION OF PRINTED CIRCUIT BOARD 182. PROFILE ON THE PRODUCTION OF PRINTED CIRCUIT BOARD 182-1 TABLE OF CONTENTS PAGE I. SUMMARY 182-2 II. PRODUCT DESCRIPTION & APPLICATION 182-3 III. MARKET STUDY AND PLANT CAPACITY 182-3 A. MARKET STUDY

More information

V-PLC9000 Product Series. Veesta Universal PLC & Teleprotection

V-PLC9000 Product Series. Veesta Universal PLC & Teleprotection Veesta World Co. V-PLC9000 Product Series 1 Veesta Universal PLC & Teleprotection ( Version 1.0 ) V-PLC9000 Product Series (1) V-PLC9000 Product Series is family of devices: Universal PLC terminal VP-9UPT

More information

2001 7½-Digit High Performance Multimeter ½-Digit High Performance Multimeter

2001 7½-Digit High Performance Multimeter ½-Digit High Performance Multimeter DMM users whose applications demand exceptional resolution, accuracy, and sensitivity combined with high throughput now have two attractive alternatives to high priced, high end DMMs. Keithley s 7½-digit

More information

TECHNICAL PAPER PRESENTATION

TECHNICAL PAPER PRESENTATION 1 W E L C O M E T O C O M E T 2 0 1 7 TECHNICAL PAPER PRESENTATION 2 ASSET MANAGEMENT ANALYTICS FOR A SUSTAINABLE GRID BY QASIM AZIZ P.E., & GAUTAM SONDE A B O U T T H E A U T H O R S C O M E T 2 0 1 7

More information

Big Country Electric Cooperative, Inc. Big Country Development Corporation

Big Country Electric Cooperative, Inc. Big Country Development Corporation Big Country Electric Cooperative, Inc. Big Country Development Corporation Dear Member, We look forward to working with you and being of service as your residential scale memberowned generation project

More information

Section A5. This Price Schedule is effective January 1, Advanced Replacement & Repair. Date Page Comment

Section A5. This Price Schedule is effective January 1, Advanced Replacement & Repair. Date Page Comment Section A5 This Price Schedule is effective January 1, 2018. Date Page Comment 1-1-18 All January, 2018 Price Schedule update. Prices and specifications subject to change without notice. Page 1 PRICE SCHEDULE

More information

January 2018 PRICE SCHEDULE A 2.0 Advanced Replacement & Repair

January 2018 PRICE SCHEDULE A 2.0 Advanced Replacement & Repair Section A5 This Price Schedule is effective January 1, 2018. Date Page Comment 1-1-18 All January, 2018 Price Schedule update. 3-15-18 7 Updated 1881-010 decoder board for 1816 system. 3-19-18 13 Added

More information

User Manual. Plenum DVI Dual Link Male/Male Cable ATP-14009

User Manual. Plenum DVI Dual Link Male/Male Cable ATP-14009 User Manual Plenum DVI Dual Link Male/Male Cable ATP-14009 www.atlona.com DESCRIPTION Rated Voltage (V) - Rated Temperature ( C) 75 Product Standard Certification CL2P Flame test NFPA 262/UL910 Application

More information

Isolation Indicator Response speed Logic level Rated input. voltage Photocoupler Yes 4 to 32 VDC 0.1 to 100 ma 100 to 240 VAC G3R-IAZR1SN High-speed

Isolation Indicator Response speed Logic level Rated input. voltage Photocoupler Yes 4 to 32 VDC 0.1 to 100 ma 100 to 240 VAC G3R-IAZR1SN High-speed Solid State Relay G3R-I/O Compact SSRs for I/O Interface with High Dielectric Strength Requirements High-speed models with optimum input ratings for a variety of sensors are available. Input Modules and

More information

CA-NLH-59 Depreciation Methodology and Asset Service Lives Page 1 of 3

CA-NLH-59 Depreciation Methodology and Asset Service Lives Page 1 of 3 CA-NLH-59 and Asset Service Lives Page 1 of 3 1 2 3 Q. Re: Calculation Procedure: Please state all reasons the Company did not propose a change to the Equal Life Group calculation procedure. To the extent

More information

MASSDEVELOPMENT UTILITIES DEPARTMENT 33 Andrews Parkway Devens, MA CURRENT TERMS AND CONDITIONS FOR UTILITY SERVICES Revised 5/23/2016

MASSDEVELOPMENT UTILITIES DEPARTMENT 33 Andrews Parkway Devens, MA CURRENT TERMS AND CONDITIONS FOR UTILITY SERVICES Revised 5/23/2016 MASSDEVELOPMENT UTILITIES DEPARTMENT 33 Andrews Parkway Devens, MA 01434 CURRENT TERMS AND CONDITIONS FOR UTILITY SERVICES Revised 5/23/2016 The following Terms and Conditions are a part of all rates,

More information

Superseding REVISED Sheet No. 38 REVISED SHEET NO. 38 Effective March 20, 2008 Effective February 6, 2014 RULE NO. 18. Net Energy Metering

Superseding REVISED Sheet No. 38 REVISED SHEET NO. 38 Effective March 20, 2008 Effective February 6, 2014 RULE NO. 18. Net Energy Metering Superseding REVISED Sheet No. 38 REVISED SHEET NO. 38 Effective March 20, 2008 Effective February 6, 2014 A. ELIGIBLE CUSTOMER-GENERATOR RULE NO. 18 Net Energy Metering Net energy metering is available

More information

TriLine-R 19 Technology. Simply Without Compromise

TriLine-R 19 Technology. Simply Without Compromise TriLine-R 19 Technology Simply Without Compromise 19 Technology for TriLine-R Simply Without Compromise The TriLine-R system from Striebel & John offers the perfect solution for spacesaving 19 technology.

More information

ARKANSAS PUBLIC SERVICE COMMISSION

ARKANSAS PUBLIC SERVICE COMMISSION 7 th Revised Sheet No. 12.1 Schedule Sheet 1 of 9 Replacing: 6 th Revised Sheet No. 12.1 12.0. ALL NIGHT OUTDOOR LIGHTING SERVICE 12.1. REGULATORY AUTHORITY The Arkansas Legislature has delegated authority

More information

Power Resistors Cooled by Auxiliary Heatsink (Not Supplied) Thick Film Technology

Power Resistors Cooled by Auxiliary Heatsink (Not Supplied) Thick Film Technology Power Resistors Cooled by Auxiliary Heatsink (Not Supplied) Thick Film Technology FEATURES System without external radiation High power / volume ratio Non-inductive Screw-on outputs Possible configuration

More information

LM6000PD/PF 3- and 5-DVP Cabinet. Product Manual (Revision A) Original Instructions. Single or Redundant DVP Power Input Versions

LM6000PD/PF 3- and 5-DVP Cabinet. Product Manual (Revision A) Original Instructions. Single or Redundant DVP Power Input Versions Product Manual 26574 (Revision A) Original Instructions LM6000PD/PF 3- and 5-DVP Cabinet Single or Redundant DVP Power Input Versions Installation Manual General Precautions Read this entire manual and

More information

The Victory Electric Cooperative Association, Inc. Schedule of Tariffs Table of Contents

The Victory Electric Cooperative Association, Inc. Schedule of Tariffs Table of Contents The Victory Electric Cooperative Association, Inc. Schedule of Tariffs Table of Contents Description Status Schedule Index All-Electric Service Active AE-17 2 Domestic Service Active D-17 3 Small Commercial

More information

CODES FOR PHARMACY ONLINE CLAIMS PROCESSING

CODES FOR PHARMACY ONLINE CLAIMS PROCESSING S FOR PHARMACY ONLINE CLAIMS PROCESSING The following is a list of error and warning codes that may appear when processing claims on the online system. The error codes are bolded. CODE AA AB AI AR CB CD

More information

MA Series. Safety, Technology & Innovation MA-16 MA-36. Description. Approvals. Operation. Applications. Declaration of Conformity

MA Series. Safety, Technology & Innovation MA-16 MA-36. Description. Approvals. Operation. Applications. Declaration of Conformity , Technology & Innovation MA Series Operating Instructions for MA-16 & MA-36 Switches KEEP THIS GUIDE FOR FUTURE REFERENCE This information is designed to help suitably qualified personnel install and

More information

Switchboard Rating for Internal Arcing Fault Clearing Time and Peak Current Withstand By: Ver Pangonilo, PEE RPEQ

Switchboard Rating for Internal Arcing Fault Clearing Time and Peak Current Withstand By: Ver Pangonilo, PEE RPEQ Switchboard Rating for Internal Arcing Fault Clearing Time and Peak Current Withstand By: Ver Pangonilo, PEE RPEQ Table of Contents I. Introduction... 1 II. Disclaimer... 1 III. Basis of Design... 1 IV.

More information

IMPORTANT INFORMATION Invitation to Bid No. RTS2-S-17 Kindly acknowledge important revisions to the terms and conditions under the bidding documents in details as follows: 1. According to Article F-15.

More information

E4E2. Ideal for Detecting Transparent Film, Transparent Bottles, and Clear Plastic Containers. Compact Ultrasonic Sensor. Ordering Information

E4E2. Ideal for Detecting Transparent Film, Transparent Bottles, and Clear Plastic Containers. Compact Ultrasonic Sensor. Ordering Information Compact Sensor Ideal for Detecting Transparent Film, Transparent Bottles, and Clear Plastic Containers Compact, vertical design with built-in amplifier allows easy mounting on small conveyor lines. Detects

More information

Square D Modbus Solution: Altivar 58 VFD

Square D Modbus Solution: Altivar 58 VFD Point Map November 1, 2004 Systems Integration Square D Modbus Solution: Altivar 58 VFD Table 1. Altivar 58 VFD Point Map, Application 4509. 1 LAO Slave Address 1to247 2 LAI Application Number 4509 3 LDI

More information

8508A Reference Multimeter Extended Specifications

8508A Reference Multimeter Extended Specifications 8508A Reference Multimeter Extended Specifications General Specifications Specifications Power Voltage 115 V Setting...100 V to 10 V rms designed for additional voltage fluctuations 10 %. 30 V Setting...00

More information

NOTICE OF AWARD OF CONTRACT S.R. 408/S.R.417 INTERCHANGE IMPROVEMENTS PHASE 1. Project No. 253F Contract No

NOTICE OF AWARD OF CONTRACT S.R. 408/S.R.417 INTERCHANGE IMPROVEMENTS PHASE 1. Project No. 253F Contract No NOTICE OF AWARD OF CONTRACT S.R. 408/S.R.417 INTERCHANGE IMPROVEMENTS PHASE 1 Project No. 253F Contract No. 001118 October 8, 2015 Bids for this project were received and opened on September 16, 2015,

More information

Nelson Electricity Ltd Asset Management Plan Update

Nelson Electricity Ltd Asset Management Plan Update Nelson Electricity Ltd Asset Management Plan Update April 2017 March 2027 April 2017 Nelson Electricity Ltd central Nelson city view In accordance with the Commerce Act Electricity Distribution Information

More information

TENDER DOCUMENT. (Advt. No. 12/ ) T T N K O A T

TENDER DOCUMENT. (Advt. No. 12/ ) T T N K O A T ENDER DOCUMEN (Advt. No. 12/2018-19) I N R K O L K A A ELECRICAL ENGINEERING DEPARMEN NAIONAL INSIUE OF ECHNICAL EACHERS RAINING AND RESEARCH, KOLKAA Block-FC, Sector-III, Salt Lake City, Kolkata- 7000

More information

Q50 Facility Study. By Tucson Electric Power Company Transmission Planning March 7, Proposed Point of Interconnection: Vail Fort Huachuca 138kV

Q50 Facility Study. By Tucson Electric Power Company Transmission Planning March 7, Proposed Point of Interconnection: Vail Fort Huachuca 138kV Q50 Facility Study Proposed Point of Interconnection: Vail Fort Huachuca 138kV By Tucson Electric Power Company Transmission Planning March 7, 2018 PREPARED BY: FACILITY STUDY PREPARED FOR: TUCSON ELECTRIC

More information

Lightstream Scroll kW ULTRACOMPACT II COMPACT AIR-COOLED CHILLERS WITH SCROLL COMPRESSORS

Lightstream Scroll kW ULTRACOMPACT II COMPACT AIR-COOLED CHILLERS WITH SCROLL COMPRESSORS Lightstream Scroll ULTRACOMPACT II COMPACT AIR-COOLED CHILLERS WITH SCROLL COMPRESSORS EXTREME EFFICIENCY WITH EER UP TO 3.29 OPTIONAL EVAPORATIVE PRE-COOLING MICROCHANNEL CONDENSING COILS COMPACT & LIGHTWEIGHT

More information

THE NARRAGANSETT ELECTRIC COMPANY TERMS AND CONDITIONS FOR DISTRIBUTION SERVICE

THE NARRAGANSETT ELECTRIC COMPANY TERMS AND CONDITIONS FOR DISTRIBUTION SERVICE THE NARRAGANSETT ELECTRIC COMPANY TERMS AND CONDITIONS FOR DISTRIBUTION SERVICE RIPUC No. 2217 Sheet 1 The following Terms and Conditions where not inconsistent with the rates are a part of all rates.

More information

Claims Equalisation Reserves information for aligned members

Claims Equalisation Reserves information for aligned members market bulletin Ref: Y4340 Title Purpose Type From Claims Equalisation Reserves information for aligned members To explain the operation of Claims Equalisation Reserves and clarify the information which

More information

Recommended Land Pattern: [mm]

Recommended Land Pattern: [mm] Dimensions: [mm] Recommended Land Pattern: [mm] Electrical Properties: Properties Test conditions Value Unit Tol. 3 Inductance 10 khz/ 0.1 ma L. mh ±30% 1 4 Rated Current @ 70 C I R.75 A max. DC Resistance

More information

RN1441, RN1442, RN1443, RN1444

RN1441, RN1442, RN1443, RN1444 TOSHIBA Transistor Silicon NPN Epitaxial Type (PCT Process) RN1441 RN1444 RN1441, RN1442, RN1443, RN1444 Muting and Switching Applications Unit: mm High emitter-base voltage: V EBO = 25V (min) High reverse

More information

REISSUED JUNE 1, 1988

REISSUED JUNE 1, 1988 REVISED SHEET NO. 29 Effective: October 28, 1966 RULE NO. 14 REISSUED JUNE 1, 1988 Service Connections and Facilities on Customer's Premises A. METER INSTALLATIONS AND MISCELLANEOUS SERVICE EQUIPMENT ON

More information

Faxed & ed responses are not acceptable - Return bid form in a sealed envelope with the bid number noted on the outside.

Faxed &  ed responses are not acceptable - Return bid form in a sealed envelope with the bid number noted on the outside. 4905 East Broadway, D-232 Bid No. B15/9903 Tucson, AZ 85709-1420 Requisition No. R0054391 Telephone (520) 206-4759 Buyer Philip Quintanilla Date 4/22/15 Page 1 Of 4 Bid must be in this office on or before:

More information

Type SF Motor-Run and Power Supply Capacitors Oil Filled/Impregnated, AC Rated, Metallized Polypropylene Capacitors

Type SF Motor-Run and Power Supply Capacitors Oil Filled/Impregnated, AC Rated, Metallized Polypropylene Capacitors Specifications Click here to view hardware Type SF, AC rated metallized polypropylene capacitors provide starting torque and power factor correction for split phase motors typically used in refrigeration

More information

EXCERPTS from the SAMS-SPCS SPS Technical Reference

EXCERPTS from the SAMS-SPCS SPS Technical Reference Problem Statement The existing NERC Glossary of Terms definition for a Special Protection System (SPS or, as used in the Western Interconnection, a Remedial Action Scheme or RAS) lacks clarity and specificity

More information

WISCONSIN ELECTRIC POWER COMPANY MICHIGAN

WISCONSIN ELECTRIC POWER COMPANY MICHIGAN Original Sheet No. A-1.00 WISCONSIN ELECTRIC POWER COMPANY MICHIGAN RATE BOOK FOR ELECTRIC SERVICE These Standard Rules and Regulations and Rate Schedules contained herein have been adopted by the Company

More information

RN1441,RN1442,RN1443,RN1444

RN1441,RN1442,RN1443,RN1444 TOSHIBA Transistor Silicon NPN Epitaxial Type (PCT Process) RN1441,RN1442,RN1443,RN1444 Muting and Switching Applications Unit in mm High emitter-base voltage: V EBO = 25V (min) High reverse h FE : reverse

More information

3M Molded Assembly 2 mm x 2 mm 2M Series

3M Molded Assembly 2 mm x 2 mm 2M Series M Molded Assembly 2 mm x 2 mm 2M Series Available in multiple sizes Sockets mate with standard 2 mm 2 mm headers and plugs Molded-in strain relief See Regulatory Information Appendix (RIA) for chemical

More information

REQUEST FOR QUOTATION

REQUEST FOR QUOTATION Return Bids By 11:00 AM, 01/25/2017 to: sendbid@cityoftacoma.org Debbie Seibert Power Warehouse Administration Building North 3628 S. 35th St. Tacoma WA 98409 Ph. 253 502 8587 Fax.253-502-8372 Material

More information

MODEL STANDING OFFER TERMS & CONDITIONS FOR BASIC CONNECTION SERVICES FOR RETAIL CUSTOMERS WHO ARE SMALL GENERATORS 3602

MODEL STANDING OFFER TERMS & CONDITIONS FOR BASIC CONNECTION SERVICES FOR RETAIL CUSTOMERS WHO ARE SMALL GENERATORS 3602 MODEL STANDING OFFER TERMS & CONDITIONS FOR BASIC CONNECTION SERVICES FOR RETAIL CUSTOMERS WHO ARE SMALL GENERATORS 3602 SA Power Networks www.sapowernetworks.com.au 3602 - MSO T_C's for BCS for Retail

More information

Input voltage Power rating Output voltage Output current Model number 400 to 500 VAC

Input voltage Power rating Output voltage Output current Model number 400 to 500 VAC Three-phase Input Switch Mode Power Supply S8VT DIN-rail mounting, Power Supply with a range of 5 A to 40 A output current 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output Higher stability, lower

More information

DISCONTINUED. Terminal Type Contact form Model Through-hole DPDT G6H-2

DISCONTINUED. Terminal Type Contact form Model Through-hole DPDT G6H-2 DISCONTINUED Low Signal Relay G6H Ultra-compact, Ultra-sensitive DPDT Relay Compact size and low 5 mm profile. Low thermoelectromotive force. Low magnetic interference enables high-density mounting. Utilizes

More information

Interconnection Process for Customer-Owned Generation (QFs)

Interconnection Process for Customer-Owned Generation (QFs) Interconnection Process for Customer-Owned Generation (QFs) Member-consumer makes Co-op letter explaining process & providing information (including co-op Application Member reviews information Member

More information

MRX-30 Owner s Manual

MRX-30 Owner s Manual MRX-30 Owner s Manual Introduction: The MRX-30 Advanced Network System Controller is designed to meet the needs of large residential or small commercial environments. Only Total Control 2.0 software, products,

More information

Xantrex XW Power System Xantrex XW / Xantrex XW / Xantrex XW /240 60

Xantrex XW Power System Xantrex XW / Xantrex XW / Xantrex XW /240 60 Xantrex XW Power System Xantrex XW4024 120/240 60 Xantrex XW4548 120/240 60 Xantrex XW6048 120/240 60 Installation Guide www.schneider-electric.com Xantrex XW Power System Installation Guide www.schneider-electric.com

More information

Item No. M2B/M2W/M2RW/M2MG Installation Guide. Computer Riser. Website: Tel:

Item No. M2B/M2W/M2RW/M2MG Installation Guide. Computer Riser. Website:  Tel: Item No. M2B/M2W/M2RW/M2MG Installation Guide Computer Riser Website: www.flexispot.com Tel: 1-855-421-2808 Specifications Step 1 The size of desktop work surface: 5.9"~ 19.7" (150 ~ 500mm) 35" (890mm)

More information

TOSHIBA Transistor Silicon NPN Epitaxial Type TMBT3904

TOSHIBA Transistor Silicon NPN Epitaxial Type TMBT3904 TOSHIBA Transistor Silicon NPN Epitaxial Type TMBT3904 Audio Frequency General Purpose Amplifier Applications High voltage and high current : VCEO = 50 V, IC = 150 ma (max) Complementary to TMBT3906 Absolute

More information

Power Utilities. Wire & Cable Tool Catalog. Power Distribution Power Transmission

Power Utilities. Wire & Cable Tool Catalog. Power Distribution Power Transmission Power Utilities Wire & Cable Tool Catalog Power Distribution Power Transmission Tools Made for the Trade We are a quality design and manufacturing company founded and based in the U.S. for over 80 years.

More information

HOLY CROSS ENERGY November 3, 2015 GENERATOR INTERCONNECT POLICY

HOLY CROSS ENERGY November 3, 2015 GENERATOR INTERCONNECT POLICY GENERATOR INTERCONNECT POLICY GENERATOR INTERCONNECT (PROCEDURE) GENERATOR INTERCONNECT (GUIDELINES) Page 1 of 50 TABLE OF CONTENTS GENERATOR INTERCONNECT (PROCEDURE)... 4 I. GENERAL OVERVIEW... 5 A. Applicability...

More information

NLC Solid State Induction Modulator LC02 Update Feb

NLC Solid State Induction Modulator LC02 Update Feb NL Solid State Induction Modulator L02 Update Feb 5 2002 SLA: R.assel, M.Nguyen,. Pappas, J. delamare LLNL:. ook, J. Sullivan, S. Hawkins BN:. Brooksby, J. Yuhas Klystron PPM focus Slide 2 onceptual NL

More information

RoHS. High brightness UL LED Panel Light LVT-PL Features. Applications. warranty 5 years

RoHS. High brightness UL LED Panel Light LVT-PL Features. Applications. warranty 5 years High brightness UL LED Panel Light Features WH F 43 LED 3000K 20 4000K 20 6000K 20 1. The Luminance uniformity of the emitting surface is over 8%. 2. All sides are lined with LED to ensure optimal illumination.

More information

T4012. Universal Tongue-Operated Safety Interlock Switch. Specifications. Safety Interlock Switches

T4012. Universal Tongue-Operated Safety Interlock Switch. Specifications. Safety Interlock Switches R Safety Interlock Switches T12 Universal Tongue-Operated Safety Interlock Switch Strong and versatile the compact size of the strong, glassfilled thermoplastic housing allows this switch to be used in

More information

ARKANSAS PUBLIC SERVICE COMMISSION

ARKANSAS PUBLIC SERVICE COMMISSION 1st Revised Sheet No. P9.1 Docket No.: 99-328-TF Replacing Original Sheet No. P9.1 Effective: 2/29/00 9.0. SERVICE REGULATIONS 9.1. APPLICABLE SERVICE AREA In all areas allocated by the Arkansas Public

More information

Public Utility District Number 1 of Klickitat County POLICY BULLETIN 21. Customer Service Policy Electric

Public Utility District Number 1 of Klickitat County POLICY BULLETIN 21. Customer Service Policy Electric Public Utility District Number 1 of Klickitat County POLICY BULLETIN 21 Customer Service Policy Electric I. Definition of Terms A. Applicant - The person(s) applying for electric service. B. Customer -

More information

Monolithic Amplifier CMA-162LN+ Ultra Low Noise, High IP to 1.6 GHz

Monolithic Amplifier CMA-162LN+ Ultra Low Noise, High IP to 1.6 GHz Ultra Low Noise, High IP3 Monolithic Amplifier 50Ω 0.7 to 1.6 GHz The Big Deal Ceramic, Hermetically Sealed, Nitrogen filled Low profile case,.045 high Ultra Low Noise Figure, 0.5 db High Gain, High IP3

More information

The Narragansett Electric Company d/b/a National Grid Tariff Advice Filing to Amend R.I.P.U.C. No Docket No.

The Narragansett Electric Company d/b/a National Grid Tariff Advice Filing to Amend R.I.P.U.C. No Docket No. Jennifer Brooks Hutchinson Senior Counsel July 13, 2012 Luly E. Massaro, Commission Clerk Rhode Island Public Utilities Commission 89 Jefferson Boulevard Warwick, RI 02888 RE: The Narragansett Electric

More information

Case Material: Molded Plastic. UL Flammability Classification Low Reverse Leakage Current

Case Material: Molded Plastic. UL Flammability Classification Low Reverse Leakage Current Pb 4A GLASS PASSIVATED BRIDGE RECTIFIER Features Mechanical Data Glass Passivated Die Construction Case: Rating to 1,000V PRV Case Material: Molded Plastic. UL Flammability Classification Low Reverse Leakage

More information

MICHIGAN ELECTRIC UTILITY

MICHIGAN ELECTRIC UTILITY MICHIGAN ELECTRIC UTILITY Generator Interconnection Requirements Projects with Aggregate Generator Output of 30 kw or More, but Less than 150 kw Effective Aug. 10, 2004 INTRODUCTION This Generator Interconnection

More information

TRI-COUNTY ELECTRIC COOPERATIVE APPLICATION AND AGREEMENT FOR INTERCONNECTION AND NET METERING OF SYSTEMS WITH CAPACITY OF 100 kw OR LESS

TRI-COUNTY ELECTRIC COOPERATIVE APPLICATION AND AGREEMENT FOR INTERCONNECTION AND NET METERING OF SYSTEMS WITH CAPACITY OF 100 kw OR LESS TRI-COUNTY ELECTRIC COOPERATIVE APPLICATION AND AGREEMENT FOR INTERCONNECTION AND NET METERING OF SYSTEMS WITH CAPACITY OF 100 kw OR LESS PROCEDURES: I. Members Applying for New Interconnection/Submission

More information