Unit Ventilator Ceiling Water Source Heat Pump

Similar documents
Formula SAE Cost Report. Dalhousie University Formula SAE Michigan 2012 Car # 47

Image Key Part Number Description Substitution Qty.

McQuay BACnet Solution: Microtech II Applied Rooftop Unit Controller with Discharge Air Control (DAC)

EXTENDED WARRANTY PROGRAM GUIDE. Qualifying Qualifying is easy. To participate, you must be registered with Factory Assurance Southwest ( FAS ).

Parts List, Charging Chart, Wiring Diagrams

Important Notice. For all repair jobs involving replacement of parts it is accept able to apply the maximum allowable time.

Maersk STS Mode 33 Genset Equipment General Remarks First figure in the 4 digit code system is used for identification of the unit type.

EX BUCKET CYLINDER 2 Replace C/O RHS Bucket 11856hrs on changed out due to leaking.

.! 4 5 2!, S E R V I C E P L A N S!)2

Lightstream Scroll kW ULTRACOMPACT II FREECOOL COMPACT FREE COOLING CHILLERS WITH SCROLL COMPRESSORS

- 430 SS Where Exposed x1. - EXHAUST RISER - Factory installed 10" X 28" x1. - SUPPLY RISER - 12"x 28" Supply Riser with Volume Dampers x3

EXTENDED WARRANTIES COMPREHENSIVE WARRANTY PROGRAM CUSTOMER PROTECTION PLAN

Fan Total Price: $748.00

JUNE 2018 COZY PARTS LIST

ADDENDUM #1 RFQ M1201M. 06/07/13 Please replace Chiller Maintenance Specifications with the attached Chiller Maintenance Specifications.

June 15, City Of Rochelle 420 N 6th St Rochelle, IL Att: Ms. Sue Messer. UPDATED: Old Building / HVAC Controls and Energy Improvements

Lightstream Scroll kW ULTRACOMPACT II COMPACT AIR-COOLED CHILLERS WITH SCROLL COMPRESSORS

***EMERGENCY ROADSIDE ASSISTANCE Call toll-free ***

LPBC ALLOWANCES LPBC ADDENDUM # 4-11/13/17 SECTION

PAN-HEAD SCREW $ PAN-HEAD SCREW $ 0.05

Energy Efficiency Opportunities Report. AMP Limited Public Report

Parts with Maintenance Release and Traceability

XML Publisher Balance Sheet Vision Operations (USA) Feb-02

Parts list for PRO Grain Bagger Model " Auger Direct Drive Apr-14 Wholesale Suggested

Optional Warranties. Dealer Program Guide

Lightstream Scroll kW ULTRACOMPACT COMPACT AIR-COOLED CHILLERS WITH SCROLL COMPRESSORS

VEHICLE SERVICE AGREEMENT CUSTOMER SERVICE 1 (800) CLAIMS IMPORTANT INFORMATION YOU NEED TO KNOW

DAYTON METROPOLITAN HOUSING AUTHORITY dba GREATER DAYTON PREMIER MANAGEMENT

PROGRAMMING GUIDE FOR PPC6000 SERIES

FACSIMILE EQUIPMENT PARTS REFERENCE LIST. MODEL: MFC7420 / 7820N DCP 7020 (For U.S.A / Canada / Brazil)

MECHANICAL BREAKDOWN INSURANCE POLICY

MERCEDES-BENZ NEW VEHICLE EXTENDED LIMITED WARRANTY AGREEMENT Valid in California ONLY

MAINTENANCE AGREEMENT

2018 Results Conference Call. March 27, 2019

FACSIMILE EQUIPMENT PARTS REFERENCE LIST. MODEL: MFC7220 / 7225N FAX2820 / 2910 / 2920 (For U.S.A / Canada / Brazil)

kW. Lightstream Screw V AIR-COOLED CHILLERS WITH SCREW COMPRESSORS

PREMIUM PROTECTION PLAN HVAC PLUMBING GENERATOR

Terms and Conditions Famous Tate Repair/Replacement Plans

CRAST INC., (hereafter CRAST ) is a corporation organized under the laws of the state of Georgia.

Tender Specification No.: 04 / of SE (CTI &Enqs.) / CTI, Dt: OPEN TENDER NOTICE

CUSTOMER ASSURANCE POLICY

Easystream kW PACKAGED SCROLL CHILLERS

December 10, Butler School District 53 1

BIC MANUAL FILL. McDonald s USA Extended Warranty Program Blended Beverage Ice Machine

PRO-GUARD CARE TERMS AND CONDITIONS

Home Comfort Certified System

PLEASE READ THIS AGREEMENT CAREFULLY

DENSO in Figures. [ Non-consolidated ] For the Year Ended March 31,2001. DENSO CORPORATION Corporate Planning Dept. Financial Planning

Lightstream Scroll kW AIR-COOLED CHILLERS WITH SCROLL COMPRESSORS

Express, 14.5HP Gear

CONGRATULATIONS! TABLE OF CONTENTS

REQUEST FOR PROPOSAL FOR: NHTI- Concord s Community College. Replacing a Cafeteria commercial dishwasher and associated equipment and finishes.

Vehicle Service Contract Terms and Conditions Diamond Coverage. Definitions

HomeServe. HomeServe BUN1129 [XX]

SERVICE WARRANTY POLICY FOR CONSUMER DURABLE PRODUCTS

STANDARD GUARANTY INSURANCE COMPANY [A STOCK INSURANCE COMPANY] (Herein called We, Us, and Our ) ASSURED MECHANICAL BREAKDOWN INSURANCE PROGRAM

Be wattsmart and earn cash back.

Terms, Conditions and Warranty

MECHANICAL REPAIR SERVICE CONTRACT

SPECIMEN MECHANICAL BREAKDOWN INSURANCE

Platinum Coverage. Vehicle Service Contract Terms and Conditions

Air Conditioner, Heat Pump, ECU, PTAC, GPac Warranty Statement and Policies

Trevor-Wilmot Consolidated School District Wilmot Road. Trevor, WI HVAC Preventative Maintenance. Request for Proposal

NO SERVICE REQUEST IS TO BE PAID WITHOUT PRIOR AUTHORIZATION TX-1030A

T-25/C-25 SHINDAIWA ILLUSTRATED PARTS LIST PIEZAS DE REPUESTO LE RÉPERTOIRE DES PIÈCES ILLUSTRÉES C-25 CYLINDER/CILINDRO/CYLINDRE

Parts List 852 Series

AUSTIN. Request for Qualifications 19RFQ082 Testing and Balancing On Call Services. RFQ opening / due date at 2:00 pm CST

CITY OF EL SEGUNDO SCHEDULE B-1 BUILDING & SAFETY FEE SCHEDULE BUILDING PERMIT FEES PROPOSED

Big Walnut Local School District

Rail Clamps Type BSZ. PINTSCH BUBENZER is certified according to DIN EN ISO 9001:2008. Safe Tried and Trusted High Performance Robust Easy Maintenance

Siemens Combustion Control Modbus Solution: LMV51

BUTLER SYSTEM WARRANTY BOOKLET

Vehicle Service Contracts GAP. Dealer Management System

Key IRS Interest Rates After PPA

INSTALLATION & OPERATING INSTRUCTIONS. PIZZA DISPENSING CABINET PDC2 Series & PDC3 Series

Spheria Australian Smaller Companies Fund

Business & Financial Services December 2017

Standard Motor Products Inc. (SMP-NYSE)

DIN ISO 9001 : 2000 QA-Nr.: Safe Tried and Trusted High Performance Robust Easy Maintenance

LIMITED PARTS WARRANTY Air Conditioning, Heating and Ventilating Equipment Designed For Manufactured Housing

* *

REQUEST FOR PROPOSAL

SUPPLEMENTAL. Home Protection Plan (877) (toll-free)

Ø mm. SYSTEM KAN-therm. High quality for reasonable price TECHNOLOGIA SUKCESU ISO 9001

INVESTMENT GRADE ENERGY AUDIT SARATOGA SPRINGS HOUSING AUTHORITY Saratoga Springs, New York. AMPs NY NY

AGREEMENT PLEASE READ THIS AGREEMENT CAREFULLY

LIPPERT HYDRAULIC LANDING GEAR PRODUCTS MANUAL E-PUB

Prescriptive HVAC Application


BUILDING PERMIT FEES

Caution: This Unit is designed for atmospheric operation. DO NOT Pressurize Receiver. PLEASE LEAVE THIS MANUAL FOR OWNER S USE

IID APPLICATION INSTRUCTIONS ENERGY REWARDS PROGRAM FOR NON-RESIDENTIAL CUSTOMERS

What did they tell me?

Heritage Warranty. Policy Document

Parts Breakdown 2704 Page 1 of 11 12/8/2008

Parts List 800 Series

Table of Contents. Section I. Definitions. Section II. Covered Parts / Components

2016 Warranty Service Policy Guide

Listing of Events Fort McMurray Roman Catholic Seperate School District Fr. M. Beauregard School

Key IRS Interest Rates After PPA

Transcription:

Replacement Parts List 110502900 Rev. B 03/03 Unit Ventilator Ceiling Water Source Heat Pump AT Sizes: 24-48 Vintage: C

Contents Parts List Revision History... 3 Nomenclature- Serial... 4 Nomenclature- Unit Model... 5 Accessories- Filters, Recess Flanges, Timeclock, Sensor Guards, Hose Kit... 6 Refrigeration Components & Cabinet- Compressor, Reversing Valve, Filter, Fan Shaft, DE Coils, Solenoid, Water Valve, Fusible Plug, Strainer, Panels... 7-9 Water Coil, Low Temp. Stat (T2), Expansion Valve,... 10 Electric Heat... 11 Discharge Air... 12 Return Air... 13, 14 20% Outdoor Air Motorized Damper... 15 100% Outdoor Air Damper Damper... 15 Controls... 16 Unit Vent, Ceiling Heat Pump- AT Rev. B 03/03 RPL 110502900/ Page 2

Parts List Revision History Revision Date Description 09/99 New A 10/02 Page 16 - Control Transformer - X5, 460V units, 20% Outdoor Air part number was changed from 4EPC9056 to 060630801. B 03/03 Page 9 - Fusible Plug part number was incorrect as 10657401 and was changed to 106057401. Visit www.ptacsolutions.com or call 1-877-PTAC-BUY (1-877-782-2289) for Sales assistance Unit Vent, Ceiling Heat Pump- AT Rev. B 03/03 RPL 110502900/ Page 3

Nomenclature Serial 7 6A 12345 01 Factory 7= Auburn, NY 6= Brownsville, TN Engineering Revision Serial Year and Month of Manufacture: Year Month V= 1990 A= Jan. W= 1991 B= Feb. X= 1992 C= Mar. Y= 1993 D= Apr. Z= 1994 E= May 5= 1995 F= Jun 6= 1996 G= Jul 7= 1997 H= Aug 8= 1998 J= Sep. 9= 1999 K= Oct. L= Nov. M= Dec. Unit Vent, Ceiling Heat Pump- AT Rev. B 03/03 RPL 110502900/ Page 4

Nomenclature Unit Model (X) A A E L E K A A AT 2 2 3 1 2 0 1 3 Code A11 A10 A09 A08 A07 A06 A05 A04 A03 A02A01 N01 N02 N03 N04 N05 N06 N07 N08 A11 A10 A09 A08 A07 A06 A05 Non Standard Construction Z= Special, w/o listing X= Special, with listing Color A= Off White Y= Special Inlet Air and Filter Type A= Bottom Return /Top OA/Throwaway Filter B= Bottom Return /Rear OA/Throwaway Filter C= Bottom Return /No OA/Throwaway Filter D= Rear Return /Top OA/Throwaway Filter E= Rear Return /Rear OA/Throwaway Filter F= Rear Return /No OA/Throwaway Filter Discharge Air Plenum With: E= Front Double Deflection Grille Electric Heat L= 2 Elements M= 3 Elements N= 4 Elements O= 5 Elements P= 6 Elements DE Coil X= Direct Expansion, RH, Standard Range E= Direct Expansion, RH, Extended Range Controls K= MicroTech Standalone, Ashrae III, 100% OA L= MicroTech Standalone, Ashrae II, 100% OA M= MicroTech Network, Ashrae III, 100% OA N= MicroTech Network, Ashrae II, 100% OA Q= Unit Mtd. Thermostat, 0% OA R= Wall Mtd. Thermostat, 0% OA, Manual C/O S= Wall Mtd. Thermostat, 0% OA, Auto C/O U= Unit Mtd. Thermostat, 20% OA V= Wall Mtd. Thermostat, 20% OA, Manual C/O W= Wall Mtd. Thermostat, 20% OA, Auto C/O I= MicroTech Ashrae III Master Unit X= MicroTech Ashrae II Master Unit Y= MicroTech Ashrae III Slave Unit Z= MicroTech Ashrae II Slave Unit A02 A01 N01 N02 N03 N04 N05 N06 N07 Model A= A Product Type T= Unit Ventilator, WSHP, Ceiling Type Unit Size 2= 24 MBH Cooling 3= 30 MBH Cooling 4= 36 MBH Cooling 5= 42 MBH Cooling 6= 48 MBH Cooling AAF Night Temperature Controls 0= None 1= Day/Night Changeover Relay- 24V 2= Day/Night Changeover Relay with Unit Mounted Night Thermostat- 24V 3= Day/Night Changeover Relay- 115V 4= Day/Night Changeover Relay with Unit Mounted Night Thermostat- 24V 5= Time Clock and Holiday Switch 6= Time Clock and Holiday Switch with Unit Mounted Night Thermostat Tenant Override and Sensor 0= None 2= Wall Mounted 5 Hour Override Timer 3= Unit Sensor 5= Wall Sensor 6= Wall Sensor w/ Tennant Override 7= Wall Sensor w/ Tennant Override and Setpoint Adjustment Face & Bypass Damper 1= None Power Supply 2= 208/60/1 3= 230/60/1 4= 265/60/1 5= 200/60/3 6= 230/60/3 7= 460/60/3 External Static Pressure 0= Free Delivery 1= 0.1" up to 0.24" External Static Pressure Fan Shaft Bearing 1= Oilable Sleeve Type A04 Heating Coil Control A= 100% OA, Electric Heat, 3 Stage R= 100% OA, No Electric Heat N= 0 or 20% OA, Single Stage Electric Heat O= 0 or 20% OA, Two Stage Electric Heat S= 0 or 20% OA, No Electric Heat N08 External Ventilation Control 0= None 3= Ventilation Control for 0% OA- 24V 4= Ventilation Control for 0% OA- 115V 5= Exhaust Fan Interlock for 100% OA- 24V 6= Exhaust Fan Interlock for 100% OA- 115V A03 Cooling Valve A= None Unit Vent, Ceiling Heat Pump- AT Rev. B 03/03 RPL 110502900/ Page 5

Accessories Filters, Recess Flanges, Timeclock, Sensor Guards, Hose Kit Description Unit Size Part Cold Weather Outdoor Air Damper 024, 030 GXA402062 036-048 GXA502062 Metal Thermostat/Sensor Guard ALL 067183401 Clear Plastic Thermostat/Sensor Guard with Lock ALL 067183301 Wall Mounted 5 Hour Night Override Timer ALL WXA3601222 Wall Mounted Occupied/Unoccupied Switch ALL GBA6014563 Remote Mounted Timeclock- Without Reserve Power ALL GEA602095 Remote Mounted Timeclock- WithReserve Power ALL GEA602096 Remote Mtd. Timeclock- 24hr. with Skip ½ Day ALL GEA602035 Remote Mtd. Timeclock- 24hr. w/skip ½ Day w/reserve Power ALL GEA602036 Renewable Filter (Roll)- 13/16" X 9 7/8" X 48 1/4" 024, 030 GOA400101 13/16" X 9 7/8" X 60 1/8" 036-048 GOA500101 Roll Filter Crank Assembly ALL GOA801003 Permanent Filter- 13/16" X 9 7/8" X 48 1/4" 024, 030 GOA400102 13/16" X 9 7/8" X 60 1/8" 036-048 GOA500102 Throwaway Filter- 13/16" X 9 7/8" X 48 1/4" 024, 030 GOA400103 13/16" X 9 7/8" X 60 1/8" 036-048 GOA500103 Renewable Filter Media (2-85' Roll Carton) ALL GOA600105 Hose Kit Assembly ALL GXA304002 Outdoor Air Damper Lock ALL GXA602039 Outdoor Air Damper Operated Switch ALL GXA602040 Unhinged Panels (Chains) ALL GXA602065 Remote Speed Switch ALL GXA485002 3 Sided Recess Flange- Units with Flat Filter 024, 030 GCA502045 3 Sided Recess Flange- Units with Flat Filter 036-048 GCA602045 3 Sided Recess Flange- Units with Roll Filter 024, 030 GCA502053 3 Sided Recess Flange- Units with Roll Filter 036-048 GCA602053 4 Sided Recess Flange- Units with Flat Filter 024, 030 GCA502049 4 Sided Recess Flange- Units with Flat Filter 036-048 GCA602049 4 Sided Recess Flange- Units with Roll Filter 024, 030 GCA502057 4 Sided Recess Flange- Units with Roll Filter 036-048 GCA602057 Unit Vent, Ceiling Heat Pump- AT Rev. B 03/03 RPL 110502900/ Page 6

Refrigeration Components & Cabinet Compressor, Reversing Valve, Filter, Fan Shaft, DE Coils, Solenoid, Water Valve, Fusible Plug, Strainer, Panels Diagrams 2 99 Front (Bottom) View 16 20 18 Bottom Panel 90 End View 19 100 3 Damper Section Lower Left Partition 9 4 1 6 5 50 Unit Vent, Ceiling Heat Pump- AT Rev. B 03/03 RPL 110502900/ Page 7

Refrigeration Components & Cabinet Compressor, Reversing Valve, Filter, Fan Shaft, DE Coils, Solenoid, Water Valve, Fusible Plug, Strainer, T4 Stat, Panels Components 1 Top Cover- Unit Sizes 24, 30 GC11791 1 Top Cover- Unit Sizes 36, 42, 48 GC11792 1 2 Blockoff GC10132 1 3 Cover GC11721 4 Trough- Unit Sizes 24, 30 GC11795 1 Trough- Unit Sizes 36, 42, 48 GC11796 1 5 Upper Damper Stop- Unit Sizes 24, 30 106011401 1 Upper Damper Stop- Unit Sizes 36, 42, 48 106011501 1 6 Lower Damper Stop- Unit Sizes 24, 30 106011001 1 Lower Damper Stop- Unit Sizes 36, 42, 48 106011101 1 16 Angle GC10159 1 18 Cover GC11719 1 19 Cover GC11720 1 20 Angle GC11722 1 50 Blockoff 056824501 1 90 Bottom Panel- Unit Sizes 24, 30 GCF5508 1 Bottom Panel- Unit Sizes 36, 42, 48 GCF5509 1 Chain for Bottom Panel GC11986 4 Ring for Chain LC318A 8 99 Fan Shaft- Unit Sizes 24, 30 GC8505 1 Fan Shaft- Unit Sizes 36, 42, 48 GC8506 1 Unit Vent, Ceiling Heat Pump- AT Rev. B 03/03 RPL 110502900/ Page 8

Refrigeration Components & Cabinet Compressor, Reversing Valve, Filter, Fan Shaft, DE Coils, Solenoid, Water Valve, Fusible Plug, Strainer, T4 Stat, Panels Components, Continued 100 Compressor- 208/230/1 Unit Size 24 WB1072 1 Unit Size 30 WB1096 1 Unit Size 36 WB1133 1 Unit Size 42 WB1137 1 Unit Size 48 WB1114 1 Compressor- 208/230/3 Unit Size 24 WB1073 1 Unit Size 30 WB1099 1 Unit Size 36 WB1135 1 Unit Size 42 WB1139 1 Unit Size 48 WB1116 1 Compressor- 265/1 Unit Size 24 WB1074 1 Unit Size 30 WB1097 1 Unit Size 36 WB1134 1 Unit Size 42 WB1138 1 Unit Size 48 WB1115 1 Compressor- 460/3 Unit Size 24 WB1075 1 Unit Size 30 WB1100 1 Unit Size 36 WB1136 1 Unit Size 42 WB1140 1 Unit Size 48 WB1117 1 N/S Filter- Unit Sizes 24, 30 GO280C 1 Filter- Unit Sizes 36, 42, 48 GO281C 1 N/S Strainer YL286 1 N/S Direct Expansion Cooling Coil- Sizes 24, 30 GRF1019 1 Direct Expansion Cooling Coil- Sizes 36,42,48 GRF1020 1 N/S Fusible Plug 106057401 1 N/S Reversing Valve- Unit Sizes 24, 30 067290301 1 Reversing Valve- Unit Sizes 36, 42, 48 067287401 1 N/S Reversing Valve Solenoid 067010001 1 N/S Low Temp. Stat T4 058915401 2 Unit Vent, Ceiling Heat Pump- AT Rev. B 03/03 RPL 110502900/ Page 9

Water Coil, T2 Low Temp. Stat, Expansion Valve, S5 & S6 Sensors Diagram and Components 1 4 2 6 4 5 6 1 Water Coil Unit Sizes 24, 30 WR1478 1 Unit Sizes 36, 42 WR1480 1 Unit Size 48 WR1481 1 2 Bracket- T2 GE1216 1 4 Low Temperature Stat T2 Units with 100% Outdoor Air 067009901 1 Units with 20% Outdoor Air 4ELN8798 1 5 Expansion Valve Unit Sizes 24, 30 106080616 1 Unit Sizes 36, 42 106080615 1 Unit Size 48 106080617 1 6 Sensor S5, S6 4EZS9158 2 Unit Vent, Ceiling Heat Pump- AT Rev. B 03/03 RPL 110502900/ Page 10

Electric Heat Components Controls N/S 5 Minute Anti Short Timer 4EWS7798 1 N/S Relay 2PST- 24V 2 Element Units 4EWJ8799 2 3 Element Units 4EWJ8799 3 4 Element Units 4EWJ8799 4 5 Element Units 4EWJ8799 5 6 Element Units 4EWJ8799 6 N/S On/Off Switch 4EAL2427 1 N/S Limit Stat 4ELN7697 1 N/S Terminal Block 4ECA8877 1 N/S Fuse- 208/230/265V Unit Sizes 24, 30 4EHG1979 varies Unit Sizes 36, 42, 46 4EHG4083 varies N/S Fuse- 460V Unit Sizes 24, 30 4EHG4082 varies Unit Sizes 36, 42, 46 4EHG4377 varies Sheet Metal and Gasket N/S Gasket BJ0270100 5' N/S Door GE1129 1 N/S Barrier GE1286 1 Heaters- Unit Sizes 24, 30: 2.66 KW N/S 208/60/1 or 208/60/3 063413602 varies N/S 265/60/1 063413702 varies N/S 230/60/1 or 230/60/3 063413606 varies N/S 460/60/3 063413610 varies Heaters- Unit Sizes 36, 42, 48: 3.33 KW N/S 208/60/1 or 208/60/3 063413603 varies N/S 265/60/1 063413703 varies N/S 230/60/1 or 230/60/3 063413607 varies N/S 460/60/3 063413611 varies Heater Harnesses N/S 208/230/265/60/1 GEF1197 varies N/S 208/230/460/60/3 GEF1383 varies N/S 208/230/60/3 (6 element only) GEF1199 varies Unit Vent, Ceiling Heat Pump- AT Rev. B 03/03 RPL 110502900/ Page 11

Discharge Air Diagram and Components 52 18 7 13 67 56 58 14 6 30 51 6 Plenum Unit Sizes 24, 30 GCF5553 1 Unit Sizes 36, 42, 48 GCF5554 1 7 Housing Unit Sizes 24, 30 GCF5516 2 Unit Sizes 36, 42, 48 GCF5516 3 13 Blower Wheel Unit Sizes 24, 30 GF110 2 Unit Sizes 36, 42, 48 GF110 3 14 Double Deflection Grille Unit Sizes 24, 30 GN1006 1 Unit Sizes 36, 42, 48 GN1007 1 18 Angle GC11878 1 30 Sound Panel 056618501 1 51 Motor Spacer GC11883 1 52 Bearing Plate GC10138 1 56 Sleeve Bearing 4ACE2556A 1 58 Motor 1/8 H. P. HAEQ5935 1 1/3 H. P. 107654201 1 67 Filler GC11915 1 N/S Motor Coupling GC5021C 1 Unit Vent, Ceiling Heat Pump- AT Rev. B 03/03 RPL 110502900/ Page 12

Return Air Diagrams 118 118 102 103 Left End View 108 119 118 101 105 109 113 113 Front View 111 104 112 113 5 Intake Parts (Bottom RA shown) 11 7 6 10 Return Air Unit Vent, Ceiling Heat Pump- AT Rev. B 03/03 RPL 110502900/ Page 13

Return Air Components N/S Angle- Duct Collar Unit Sizes 24, 30 GC10141 2 Unit Sizes 36, 42, 48 GC10142 2 N/S Angle- Duct Collar GC10144 2 5 Blockoff Unit Sizes 24, 30 GC10602 2 Unit Sizes 36, 42, 48 GC10603 2 6 Filter Stop Unit Sizes 24, 30 GC10158 1 Unit Sizes 36, 42, 48 GC10159 1 7 Blockoff GC11733 2 10 Rear Panel- Bottom Return Air Unit Sizes 24, 30 GCF5533 1 Unit Sizes 36, 42, 48 GCF5534 1 Rear Panel- Rear Return Air Unit Sizes 24, 30 GCF5537 1 Unit Sizes 36, 42, 48 GCF5538 1 11 Access Panel- Bottom Return Air Unit Sizes 24, 30 GCF5525 1 Unit Sizes 36, 42, 48 GCF5526 1 Access Panel- Rear Return Air Unit Sizes 24, 30 GCF5523 1 Unit Sizes 36, 42, 48 GCF5524 1 101 Damper, Outside Air Unit Sizes 24, 30 106010401 1 Unit Sizes 36, 42, 48 106010501 1 102 Damper, Return Air Unit Sizes 24, 30 106095901 1 Unit Sizes 36, 42, 48 106096001 1 103 Angle Unit Sizes 24, 30 056670802 1 Unit Sizes 36, 42, 48 056670803 1 104 Support GC11192 1 105 Link GC10041 1 108 Crank GCF5474 1 109 Crank GCF5000 1 111 Shaft 105621801 1 112 Damper Shaft 105621601 1 113 Bearing 4ACN1491 5 118 Mohair Unit Sizes 24, 30 BY0010100 17' Unit Sizes 36, 42, 48 BY0010100 21' 119 Gasket Unit Sizes 24, 30 BJ0270100 7' Unit Sizes 36, 42, 48 BJ0270100 6' N/S Damper Spring 057088801 1 Unit Vent, Ceiling Heat Pump- AT Rev. B 03/03 RPL 110502900/ Page 14

20% Outdoor Air Motorized Damper Components N/S Bracket GE1122 1 N/S Linkage GE1124 1 N/S Damper Stop GE1125 1 N/S Damper Spring WC2026 2 N/S Crank Assembly GEF1294 1 N/S Crank Arm WCF806 1 N/S Damper Motor WB1018 1 N/S Damper Motor Harness 056601302 1 N/S Damper Switch- SPDT 4EAL7759 1 100% Outdoor Air Damper Components N/S Rod GE1131 1 N/S Actuator 105600401 1 N/S Actuator- Wire Harness 106001101 1 N/S Swivel Hinge 4HE21661 1 N/S Crank Arm 4HF24431 1 N/S Actuator Bracket GE1033 1 Unit Vent, Ceiling Heat Pump- AT Rev. B 03/03 RPL 110502900/ Page 15

Controls Components N/S Compresor Contactor R1 4EXJ1907 1 N/S Compressor Lockout Relay R7 4EWJ6454A 1 N/S MicroTech PC Board 107627201 1 Standoff for PC Board 802012415 4 N/S Outdoor Air Sensor- 20" Leads 056612404 1 N/S Room Air Sensor 4EZS9158 1 Room Air Sensor Mount GC12315 1 N/S Night Setback Switch- 20% OA Units Units with Electric Heat 4ELN7719 1 Units without Electric Heat 4EMB5471C 1 N/S Mixed Air Sensor GEF2379 1 N/S Mixed Air Temperature Control 056612404 1 N/S Manual Changeover Switch 073398001 1 Knob for Manual C/O Switch ZAG25258A 1 N/S Wall Mounted Thermostat 4ELN7919 1 Wall Mounted Thermostat Subbase 4ELN7920 1 N/S R5 Day/Night Relay- 24V (N02= 1) 4EWJ9054 1 N/S R5 Day/Night Relay- 24V (N02= 2) 4ELN7719 1 N/S R5 Day/Night Relay- 115V (N02= 3) 4EWJ9053 1 N/S Night Setback Thermostat- Unit Mtd. (N02=4) 4ELN7719 1 N/S Holiday Switch (N02= 5) 4EAL7260 1 N/S Time Clock (N02= 5) 4ETA9094 1 N/S 5 Hr. Override Timer- Wall Mounted (N03= 2) 063114601 1 N/S Unit Mounted Sensor S2 (N03= 3) GEF1947 1 N/S Wall Mounted Sensor S2 (N03= 5) 058899301 1 N/S Wall Mtd. Sensor w/ Tennant Override (N03= 6) 058899311 1 N/S Wall Mtd. Sensor w/ T.O. & Setpoint Adj. (N03= 7) 058899341 1 N/S Relay- Ventilation Control- 24V (N08=3, 5) R6 4EWJ9054 1 N/S Relay- Ventilation Control- 115V (N08=4, 6) R6 4EWJ9053 1 N/S Control Transformer- X5, 208/230 Volt Units 100% Outdoor Air 063042401 1 20% Outdoor Air Units 063042401 1 Control Transformer- X5, 460V Units 100% Outdoor Air 063042401 1 20% Outdoor Air Units 060630801 1 Unit Vent, Ceiling Heat Pump- AT Rev. B 03/03 RPL 110502900/ Page 16