June 15, City Of Rochelle 420 N 6th St Rochelle, IL Att: Ms. Sue Messer. UPDATED: Old Building / HVAC Controls and Energy Improvements

Similar documents
Texas Energy & Automation Management Solutions

.! 4 5 2!, S E R V I C E P L A N S!)2

Walton County School District Bay Elementary School New Administration Suite

PROGRAMMED MAINTENANCE Planned Maintenance Program

Contractor Service Agreement

Trevor-Wilmot Consolidated School District Wilmot Road. Trevor, WI HVAC Preventative Maintenance. Request for Proposal

POCATELLO/CHUBBUCK SCHOOL DISTRICT NO. 25 Bannock County. Administration Office 3115 Pole Line Road Pocatello, Idaho SPECIFICATIONS FOR

LPBC ALLOWANCES LPBC ADDENDUM # 4-11/13/17 SECTION

ATTACHMENT A - STATEMENT OF WORK INVITATION TO BID FOR FIRE SPRINKLER SYSTEM INSPECTIONS ITB NO.: DMS-14/15-004

Cedar Falls CSD. Project Proposal. April 3, 2018

City of Biddeford, Maine

9124 Grand Avenue South Bloomington, MN (952) Toll Free (866)

ADDENDUM #1 RFQ M1201M. 06/07/13 Please replace Chiller Maintenance Specifications with the attached Chiller Maintenance Specifications.

EXTENDED WARRANTY PROGRAM GUIDE. Qualifying Qualifying is easy. To participate, you must be registered with Factory Assurance Southwest ( FAS ).

Maintenance and Service of the JIPSD HVAC. Charleston, SC

Total Care Program Agreement

SERVICE PLANS TERMS & CONDITIONS

Warranty Policy & Procedures

Tender Specification No.: 04 / of SE (CTI &Enqs.) / CTI, Dt: OPEN TENDER NOTICE

HVAC Replacement Units

DAYTON METROPOLITAN HOUSING AUTHORITY dba GREATER DAYTON PREMIER MANAGEMENT

British Gas Repair and Care Terms and Conditions

OAK HILL ELEMENTARY SCHOOL HVAC RENOVATION PROJECT HIGH POINT, NC March 21, Addendum #2

ILLINOIS VALLEY COMMUNITY COLLEGE (Purchasing Department) 815 N. Orlando Smith Ave. Oglesby, Illinois REQUEST FOR PROPOSAL

HVAC COMPREHENSIVE MAINTENANCE AGREEMENT SUMNER COUNTY

EXTENDED WARRANTIES COMPREHENSIVE WARRANTY PROGRAM CUSTOMER PROTECTION PLAN

NORTH CAROLINA WEATHERIZATION ASSISTANCE PROGRAM SUBCONTRACTOR AGREEMENT - PLUMBING

Laramie County Community College 1400 East College Drive, Cheyenne WY Phone: (307)

Questions by Vendors: District Answers are in Red. Vendor Questions are in Black.

Home Comfort Certification System

General Conditions for Construction GCC201. Contract Type: Document No. for the following PROJECT: (Name and location or address) EXAMPLE

POLICE STATON HEATING, VENTILATION AND AIR CONDITIONING MODIFICATIONS CITY PROJECT NO CITY OF SAN MATEO, CALIFORNIA

The Hotel Roanoke & Conference Center Invitation for Bid

RRC STAFF OPINION PLEASE NOTE: THIS COMMUNICATION IS EITHER 1) ONLY THE RECOMMENDATION OF AN RRC

BUILDING PERMIT FEES

REQUEST FOR PROPOSALS RFP#74-18

SAMPLE RMG MORTGAGES HOME SYSTEM SERVICE PLAN TERMS AND CONDITIONS DEFINITIONS. For Repair Services please call

Terms, Conditions and Warranty

2 YEAR SERVICE PLAN FOR SOLAR GENERATORS

WHITE PLAINS MECHANICAL CODE PART 1. GENERAL REQUIREMENTS

CULLIGAN EQUIPMENT SERVICE/SALES: GENERAL TERMS AND CONDITIONS

REQUEST FOR BID POLE BUILDING CONSTRUCTION

REQUEST FOR QUALIFICATIONS #2016-XXX

FLORIDA LIFE-CYCLE COST ANALYSIS PROGRAM For Sustainable State Agencies

BIC MANUAL FILL. McDonald s USA Extended Warranty Program Blended Beverage Ice Machine

1 r. "' -o-. " 1 r. Whynter Compressor Cooling Built-in Wine Refrigerator. Instruction Manual ===== I/ "" MODEL# : BWR-18SD I BWR-33SD

t Terms and Conditions

Subcontractor Contract and Scope of Work MECHANICAL Social Security Administration Auburn, AL Ross Clark Circle Dothan, Alabama 36301

Limited Warranty Replacement Pledge. Warranty effective for equipment manufactured after January 1, 2013.

REQUEST FOR BIDS. MCC HVAC Replacement Units

Limited Warranty Quality Pledge. Warranty effective for equipment manufactured after January 1, 2013.

Document A General Conditions of the Contract for Construction, Construction Manager as Adviser Edition

Reserve Request Instructions: Documentation Requirements

HVAC Forensics: Uncovering the true cause of loss to HVAC systems. Curtis M. VanNess Field Operations Manager

HomeServices Terms and Conditions

11. ENERGY PERFORMANCE CONTRACT SOUTHAMPTON COUNTY OFFICE CENTER

For inner cleaning, contact an Authorized Service Center or a dealer. Do not use harsh detergent that causes corrosion or damage on the unit.

DPS MIHS roof top HVAC replacement

Preventative Maintenance Agreement Prepared for Stratfor.com

North Shore Gas Company. Billing and Price Book. Published September 2016

Housing Development Corporation of Rock Hill. Request for Proposal HOME REPAIR 710 S. YORK AVE., ROCK HILL, SC 29730

Document A201 TM 2007 SP

Rabindranath Tagore Centre Indian Council for Cultural Relations 9A, Ho Chi Minh Sarani, Kolkata T: / 0314

Document A201 TM. General Conditions of the Contract for Construction. (Name and location or address)

EQUIPMENT BREAKDOWN ENHANCEMENT ENDORSEMENT

Boiler Care Products. Terms and Conditions

Save energy at home Residential gas heating rebates

AIA Document A201 TM 1997

Replace Chiller System RFP 2018 Q&A

University of Maine System Supplementary Requirements to AIA Document B Standard Form of Agreement Between Owner and Architect

Westmount Place Renovations Policy

SERVICE CONTRACT Terms and Conditions

Home Comfort Certified System

Tacoma Power Conservation Contractor Agreement

Consumer terms and conditions

If you are a reseller of products, you must also include a copy of your state tax ID form.

CITY OF ALHAMBRA SEPTEMBER 10, 2018 RFP2M CONTRACT DOCUMENTS & REQUEST FOR PROPOSAL

DESCRIPTION. High Sierra Systems ship complete with the following features and accessories:

THE FIRST SIX MONTHS ARE COMPLIMENTARY

PIERCE COUNTY LIBRARY SYSTEM. REQUEST FOR QUALIFICATIONS (RFQ) for ENGINEERING SERVICES FOR HVAC AND RELATED DESIGN

Air Conditioning Services Terms and Conditions

BROKEN ARROW PUBLIC SCHOOLS 701 SOUTH MAIN BROKEN ARROW, OK PHONE (918) Request for Bid Ventilation System for Plant Operation #B12-23

MAINTENANCE SERVICE ANNEX CONTRACT

LIMITED PARTS WARRANTY Air Conditioning, Heating and Ventilating Equipment Designed For Manufactured Housing

APPLIANCE ASSURANCE REPLACEMENT PLAN TERMS AND CONDITIONS

AIA Document A201 TM 1997

McQuay BACnet Solution: Microtech II Applied Rooftop Unit Controller with Discharge Air Control (DAC)

2016 Residential HVAC Rebate Application

AIA Document A201 TM 2007

Service Line Coverage

MONTCLAIR PUBLIC LIBRARY ESSEX COUNTY, NEW JERSEY NOTICE TO BIDDERS

Certifire TM. 1and 3-year fireplace protection plans for your home.

CITY OF BIRMINGHAM, MICHIGAN REQUEST FOR PROPOSALS (RFP) WIRELESS NETWORK

Service Proposal. Re:Replace 160 ton chiller on roof of Hidalgo County Administration Building

The first 6 months are complimentary

Variable Frequency Drives Application - July 1, 2016 through June,

SECTION 7 WARRANTY REQUIREMENTS

PRODUCT WARRANTY POLICIES AND PROCEDURES

ULTRASOUND SYSTEMS (UL)

Lightstream Scroll kW ULTRACOMPACT II COMPACT AIR-COOLED CHILLERS WITH SCROLL COMPRESSORS

Transcription:

City Of Rochelle 420 N 6th St Rochelle, IL 61068 Att: Ms. Sue Messer June 15, 2018 Helm Group Mechanical Inc Advanced Automation Solutions Group 2279 Route 20 East Freeport, Illinois 61032 UPDATED: Old Building / HVAC Controls and Energy Improvements Dear Sue: Mechanical Inc. appreciates the opportunity in providing you our proposed upgrades to the existing buildings HVAC equipment and controls. This proposal has been updated on pricing and splitting the scope into phases for your convenience. The defined scope still remains consistent to our content in our original proposal dated September 16, 2013 on our building assessment. It has now been five additional years since that assessment and there are some added components we now need to address. The condensing units associated with the Air Handling Units (AHUs) are past ASHRAE equipment life standards and are still using R22 refrigerant which is no longer used and is very costly to maintain and will soon be an EPA issue. Since we are still looking at this upgrade from an energy perspective, these units are not efficient with also declining copper rigidity which will start creating refrigerant leaks. We are proposing to overhaul the AHUs as well as replace the condensing units on both AHUS to create a more reliable and energy efficient solution as well as adding DDC controls to them so it all can be operated through the same platform that is currently on the newer section. AHU-1 does have a ruptured heating coil that will need to be replaced, so we should do this at the same time we are rehabbing that AHU. As in our original assessment for energy savings and comfort control, we are still advocating modifying the existing pneumatic reheats that are on the AHU systems with two options. One option would be to replace the pneumatic thermostats with ones that are now have an option of being wireless. As of now, you do not have any DDC control of these and thermostats could be left in full heat position with no one in the room. The wireless scenario would at least give you feedback of the actual temperature, control the set-point, and have a schedule on them which would help save energy from the Boiler to the AHUs energy consumption. This option is the least costly as compared to a VAV system as we discussed back in 2013. We have also updated this pricing if this is something you may still want to consider. Unlike in the newer section with the voting system, the old section would become truly a VAV controlled system which would benefit comfort control, but also huge energy savings by reducing AHU fan energy as well as compressor and boiler consumption by reducing based on actual demand versus the system running all the time fully on. Included in this upgrade would be the cleaning of the hot water coils in the system and an air balance of both which we are sure has not been addressed since original installation. The following is our detailed scope of work for each discipline. Note that since it is not known if you will do the whole project at one time or individual scopes, a discount price will be given below for the AHUs / Boiler Controls if we can do at the same time.

Typical AHU Scope of Work - $69, 795.00 per each AHU o Furnish Mechanical Modification and Controls for AHUs (Typical of each) Furnish / Install all sensors required to meet control requirements Supply Air Temp Return Air Temp Mixed Air Temp Return Air Humidity Freeze-stat Duct Static Pressure Filter status Building Pressure Furnish Control of existing pneumatic HW Valve Furnish / Install Electronic Actuators for Dampers Furnish / Install new high efficiency VFD rated motor Furnish / Install new Variable Speed Drive for AHU Furnish / Install new Sheaves, Pulleys & Belts Furnish / Install new Refrigerant Coil in existing AHU Furnish / Install all new piping specialties for cooling coil o Furnish / Install New Condensing Unit for DX Cooling with Communication to BAS Furnish Crane Furnish Removal from Site and refrigerant recovery of R22 for existing condensing unit Set New Condensing Unit Furnish / Install New refrigerant Piping Furnish new Isolation Rails Modify Electrical Connections as required o Furnish all mechanical system startup / BAS programming / Graphics for full functional system o Furnish specialized control sequences as required o Furnish Drawings / Engineering Documents / As-built drawings AHU -1 Heating Coil Replacement : $ 9, 925.00 o Furnish / Install New Hot Water Coil Drain Existing Heating Coil Remove Old Coil Install New Coil Bleed air out of new coil\ Check operation Furnish DDC To Existing Boiler: $ 19, 588.00 o Furnish / Install New Control System for Boiler o Furnish / Control Wiring of all HW Pumps o Start / Stop / Command / Alarm o Furnish / Install HW System Sensors Supply & Return o Furnish / Install control of (5) HW Building Circ. Pumps o Combustion Intake Fans / Exhaust Fans o Furnish / Control of EF s o Furnish specialized control sequences as required o Furnish Drawings / Engineering Documents / As-built drawings Note: This does not include upgrading the burner assembly as previously quoted as City of Rochelle has now decided to omit that scope

Replace Existing Pneumatic Stats with Pneumatic Wireless Stats - $46, 237.00 o Pneumatic Wireless Stat System (Typical of 14 Duct Reheat Zones & 14 Convector Zones) Remove Existing Pneumatic Stat Furnish / Install New Wireless Pneumatic Stat Furnish / Install (1) Wireless Router Per Floor (2) Required Furnish / Install (1) BAS Interface Duct Reheat Conversion to VAV Boxes and Perimeter Control - $76, 365.00 o VAV boxes Conversions w/ Reheat (Typical of 14 Duct Reheat Zones) Furnish / Install Damper Conversion boxes into duct work Furnish Cleaning of Reheat Coils in duct work Furnish / Install Controllers on damper conversion boxes Furnish / Install Supply Air Temp Sensors Furnish / Install VAV Space Sensors For VAVs Furnish / Install Space Sensors for (14) Perimeter Reheat Zones Provide control of existing (28) reheat coil valves (14) on Reheat Coils in Ductwork (14) Perimeter Zones Note: We are not replacing the existing pneumatic valves due to Asbestos issues. We will utilize what is there now within out disturbing the area or pneumatics for them. Furnish / Install Communication buss Furnish / Install 24vac power to VAV controllers o Furnish Air Balance of AHU and VAVs. o Note: Assumes the AHU project has been completed as the DDC controllers for each AHU will tie into the BAS from that project. Option 1 - TOTAL PROJECT PRICE (Discounted) $ 162, 000.00 NOTE: This is for doing Both AHUs, AHU-1 Heating Coil & Boiler Controls Option 2 - TOTAL PROJECT PRICE (Discounted) $ 206, 776.00 NOTE: This is for doing Both AHUs, AHU-1 Heating Coil, Boiler Controls & Pneumatic Wireless Stats Option 3 - TOTAL PROJECT PRICE (Discounted) $ 234, 595.00 NOTE: This is for doing Both AHUs, AHU-1 Heating Coil, Boiler Controls & VAV Conversion

Exclusions / Clarifications : Excluded are overtime and premium time. We define straight time as 6:00AM to 2:30PM, Monday through Friday. Excluded are taxes, any allowances, bid bonds, fees or permits. Excluded are cutting, roof penetrations, patching, painting. Excludes all Certified Fire-stopping Excludes any troubleshooting / replacement of Hot Water Valves leaking or dampers found defective. A separate price will be provided at the time We assume for this project that the Boiler System is good working order. Assumes accessibility to areas during working hours. We acknowledge critical areas we must work in and compensate them within the facility such as the 911 and Jail areas. The new AHUs and VAVs DDC will be as of the same system currently installed within the newer section. Excludes Any Abatement or containment thereof. If found in the systems we have encompassed we will alert the City of Rochelle. Please review and if there are questions or if additional information is needed, feel free to contact me. Respectfully, Jay Pitcher ME, CEM Controls Division Manager Advanced Automation Solutions Group Helm Group Customer Signature Customer acknowledges all terms and conditions within the document Date

TERMS & CONDITIONS No other terms, including those on Applicant s Purchase Order, may add to, modify, supersede or otherwise alter the TERMS contained herein, without the express written approval by an authorized of representative of Mechanical Inc. All other terms are hereby rejected. By allowing Mechanical Inc., to complete work described herein, Customer hereby agrees to the following terms and conditions. Customer agrees to promptly notify us of any unusual operating conditions of the subject equipment or problems with workmanship in regard to work that was performed as defined by the proposal attached with this form. Customer understands that Advanced Automation Solutions Group of Mechanical Inc. has a 24 hour, 7 day a week answering service to respond to any issues. Customer further understands and agrees that if customer fails to so notify AAS Group / Mechanical Inc. in a timely manner, of any problems or unusual operating conditions of the subject equipment or problems with workmanship, then AAS Group / Mechanical Inc., shall not be liable for any and all claims, losses, costs, and damages, including but not limited to attorney's fees and other such damages to the extent caused by the customer s failure to provide the required notification. During the performance of any work under this agreement, The AAS Group / Mechanical Inc. agrees to carry commercial general liability insurance and worker s compensation insurance in the amount required by the Customer or contract as required. Damages of any type relating to the installed system or its operation within a new or existing facilities; even if by our negligence, will be limited by to the total amount of funds received for the total of this contract amount. AAS Group / Mechanical Inc. is not responsible for viruses and/or network issues that may arise from any/all field laptops that connect to a customer s LAN, WAN, or other computer network. Problems relating to abuse, vandalism, power failure or power quality issues, misuse, fire, lightning, flood, or other Acts of God or acts of third parties other than AAS Group / Mechanical Inc, or its employers, subcontractors or agents are not covered. Repairs necessitated by these items will be billed to the customer at our normal rates. The AAS Group / Mechanical Inc. will not be responsible for any problems, costs, liabilities, damages, etc. caused by another firm, company or individual not directly employed or authorized by AAS Group / Mechanical Inc. who tampers with, changes, modifies or services any part of the system referenced by this contract. PAYMENT TERMS Payment terms include monthly progress billings and are due on a net thirty (60) days basis. Work described by this proposal could be suspended if monthly progress payments are not made on a timely basis. Should this account be referred to a collection agency or attorney for failure to pay in accordance with the terms and conditions of this agreement, the customer agrees to all collection costs, reasonable attorney fees, and 18% interest annually or 1.50% per month until date of full payment. All warranty coverage listed herein will be suspended until such time as any and all past due payments are received by Mechanical Inc. System s operational compliance with the specifications will be demonstrated to the customer or customer s representative at substantial completion of this project. This compliance may not be passed to the customer in its entirety until final payment is received by Mechanical Inc. I/we have read and agree to the terms and conditions as listed above. Customer or Authorized Agent: Printed Name Signature Date: