R-407C REFRIGERANT LORC, LNH, LNL, LNQ AND LNX SERIES OUTDOOR AIR-COOLED REMOTE CONDENSERS STANDARD FEATURES VERTICAL DISCHARGE

Similar documents
R-410A REFRIGERANT LORC, LNH, LNL, LNQ AND LNX SERIES OUTDOOR AIR-COOLED REMOTE CONDENSERS STANDARD FEATURES VERTICAL DISCHARGE

Lightstream Scroll kW ULTRACOMPACT COMPACT AIR-COOLED CHILLERS WITH SCROLL COMPRESSORS

Lightstream Scroll kW AIR-COOLED CHILLERS WITH SCROLL COMPRESSORS

DESCRIPTION. High Sierra Systems ship complete with the following features and accessories:

kW. Lightstream Screw V AIR-COOLED CHILLERS WITH SCREW COMPRESSORS

Lightstream Scroll kW ULTRACOMPACT II COMPACT AIR-COOLED CHILLERS WITH SCROLL COMPRESSORS

Easystream kW PACKAGED SCROLL CHILLERS

F Series Fluid Coils. Product Guide. Fluid Coolers Chilled Water Coils Hot Water Coils Special Fluids Gases.

Powerstream Screw kW R134a WATER COOLED DUAL-CIRCUIT SCREW CHILLERS

Lightstream Screw kW AIR-COOLED CHILLERS WITH SCREW COMPRESSORS CLASS A ENERGY EFFICIENCY MICROCHANNEL CONDENSERS RELIABLE SCREW COMPRESSORS

Lightstream Screw kW AIR-COOLED CHILLERS WITH INVERTER SCREW COMPRESSORS

INSTALLATION & MAINTENANCE INSTRUCTIONS MASTER-EX MODELS DDP14 - DDP50

Lightstream Scroll kW ULTRACOMPACT II FREECOOL COMPACT FREE COOLING CHILLERS WITH SCROLL COMPRESSORS

INSTALLATION & MAINTENANCE INSTRUCTIONS MODEL DDPV50 and DDPV54

LPBC ALLOWANCES LPBC ADDENDUM # 4-11/13/17 SECTION

.! 4 5 2!, S E R V I C E P L A N S!)2

QML35. Cover. Voltage A = 5V (+/- 5%) B = 3.3V (+/- 5%)

City of Waukegan 100 N. Martin Luther King Jr. Ave. Waukegan, IL (847) (847) fax BID DOCUMENTS FOR OUTDOOR WARNING SIREN SYSTEM

Caution: This Unit is designed for atmospheric operation. DO NOT Pressurize Receiver. PLEASE LEAVE THIS MANUAL FOR OWNER S USE

Bid Packet Page 1 of 12

ASTRO 2 CIRCULATORS. ASTRO 2 3-Speed Circulators (except Astro 286):

EXTENDED WARRANTY PROGRAM GUIDE. Qualifying Qualifying is easy. To participate, you must be registered with Factory Assurance Southwest ( FAS ).

Air Conditioner, Heat Pump, ECU, PTAC, GPac Warranty Statement and Policies

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER LABORATORY MIXING SKID

QM35. Cover. Output. A = Line Driver B = Line Driver (ABZ) /Open Collector (UVW) C = Dual Votage Line Driver (ABZ)/ Open Collector (UVW)

र य गक स थ न प द र क र ल NATIONAL INSTITUTE OF TECHNOLOGY PUDUCHERRY Karaikal Tender Document

Connecting Garage Door Jambs to Building Framing

PROCEDURAL HISTORY AND FACTUAL BACKGROUND

DIRECTORATE OF CIVIL AVIATION GOVERNMENT OF UTTAR PRADESH LUCKNOW AIRPORT, LUCKNOW

TOTAL COST ITEM # QUANTITY UNIT DESCRIPTION Unit Cost FOR 2 UNITS

Double Riser Swage INSTALLATION MANUAL

Q&A Distribution equipment and materials

SUPER WEDGE DRIVES 3V, 5V, AND 8V CROSS SECTIONS SPECIAL MADE-TO-ORDER SHEAVES USE WITH FUL-GRIP (QD) BUSHINGS

Home Owner Association (HOA) Welcome Package

Xantrex Complete Charge Controller Supplemental Owner s Manual Rev 1.0 Copyright 2012

MODIFIED REQUEST FOR PROPOSALS. PROFESSIONAL SERVICES FOR FD Training & Logistics Facility Geothermal Test Well Activity ID

INSTITUTIONAL BIDDING PROCESS No. UNDPGCCA/SUR/IICA/02/2017

PROJECT INFORMATION. Catalog No. SHIELDING SHIELDING. DRIVER E Fixed Output ESD Step Dimming 6 ED 0-10V Dimming ED1 0-10V 1% Dimming 6

Powerstream Turbo kW WATER COOLED TURBOCOR-BASED CHILLERS

BID RESPONSE LABEL THIS LABEL FOR USE WITH UNITED STATES POSTAL SERVICE DELIVERY PURCHASE OF SIGNS AND SIGN ACCESSORIES (DATE): NOV.

AUSTIN. Request for Qualifications 19RFQ082 Testing and Balancing On Call Services. RFQ opening / due date at 2:00 pm CST

HVAC Forensics: Uncovering the true cause of loss to HVAC systems. Curtis M. VanNess Field Operations Manager

#161. Connecting Garage Door Jambs to Building Framing. Introduction

Ultra High Vacuum Met-Seal Flanges

Draft Measure Information Template Cooling Tower Efficiency and Turndown

ST. TAMMANY PARISH PATRICIA P. BRISTER PARISH PRESIDENT

CITY OF MORRISTOWN, TENNESSEE INVITATION TO BID SCOREBOARDS INVITATION TO BID. Office of Finance 100 West First North Street Morristown, TN 37814

REQUEST FOR PROPOSAL FOR: NHTI- Concord s Community College. Replacing a Cafeteria commercial dishwasher and associated equipment and finishes.

LSB-1 & LSR-1 L- BAR SEALER & SHRINK TUNNEL PACKAGING SYSTEM

Lesson 2: The Homeowners Policy

Policy E-06: Added (c) to reflect policy (no change). April 1, 2013 Policy E-09: Added more information to reflect changes in QFR process.

Model QTS3QCB. Climate Control ol Series. Parts Manual Record of Change 3C. Manual No C3. February 2010 Edition

Fan Guards 25mm - 52mm (1-2 )

Tender document Estate Maintenance Department Web : Phone :

REQUEST FOR PROPOSAL

200. PROFILE ON THE PRODUCTION OF WOOD SCREW & RIVETS

NODIA AND COMPANY. GATE SOLVED PAPER Chemical Engineering Plant Design and Economics. Copyright By NODIA & COMPANY

Candock limited warranty

ORIGINAL YEAR OF CONSTRUCTION NUMBER OF BUILDING STORIES 2/6/2013 BUILDING SURVEY DATE

ATTIC FAN - DECEMBER 1995

Parts List, Charging Chart, Wiring Diagrams

City of Portsmouth Portsmouth, New Hampshire Public Works Department INVITATION TO BID

IHOL-8AR / IRA800 8 Gravity LED Adjustable

High pressure centrifugal pumps

INVITATION FOR QUOTATION. TEQIP-II/2015/GJ1G02/Shopping/M-CE-05

Fan Total Price: $748.00

SCALPERATOR GUIDE. 24 and 48 SCALPERATOR AGRIBUSINESS CAPACITIES 24 MODULAR SCALPERATOR

NOTICE OF ADOPTION OF FINAL RULE. Department of Environmental Protection. Statement of Basis and Purpose of Rule

SCALPERATOR GUIDE 24 MODULAR SCALPERATOR 24 AND 48 SCALPERATOR AGRIBUSINESS AND PLASTICS 24 AND 11 SCALPERATOR LOW PROFILE AGRIBUSINESS

- 430 SS Where Exposed x1. - EXHAUST RISER - Factory installed 10" X 28" x1. - SUPPLY RISER - 12"x 28" Supply Riser with Volume Dampers x3

SILENCERS. APPLICATIONS Heavy-duty Silencers for marine applications.

INSTRUCTION FOR COMPLETING COMPETITIVE SOLICITATION ACKNOWLEDGEMENT FORMS

ETN Evo. Plastic Lined Magnetic Drive Centrifugal Pumps. ETN Evo 50 ETFE. Pompe S.r.l. Comply to : 2006/42/CE. Design to : sub - ISO 2858

Compression Springs Heavy Duty Series

Installation Guide. Product Code: DLCEL. T: F: Page 1 of 5 PRODUCT #: DLCEL

BID # Ambulance E450 Van Chassis

Model QTS-5. QTS Industrial Series. Parts Manual

THERMOPILE DETECTORS FOR MEASUREMENT. TPD 1T 0224, TPD 1T 0524, TPD 1T 0624 General-Purpose Thermopile

AAON REPORTS RECORD FIRST QUARTER SALES BUT LOWER PROFIT

REQUEST FOR PROPOSAL(RFP) / TENDER DOCUMENT GYM EQUIPMENTS

Maintenance Instructions & Parts List

Housing Authority of the Cherokee Nation

2018 Non-Residential Rebates

BAS70-00-V to BAS70-06-V

Fittings Trade Net Price Sheet - CAD$

13. Manufacturer's warranty Marking 6 W A R N I N G!

Home Comfort Certification System

IRIS TUBE INSPECTION. Item Inspected: Unit 123. Date Commenced: 01/01/2015. Date of Completed: 12/01/2015

scalpers and band saws Aluminium industry solutions

SUPER DUTY ROLLING METAL LADDER. Cotterman Co.

BID PACKAGE LEGAL NOTICE - BIDS WANTED GENERAL INFORMATION AND INSTRUCTION (IF YOU CHOOSE NOT TO SUBMIT A BID, PLEASE COMPLETE PAGE 30)

150. PROFILE ON THE PRODUCTION OF AC MOTORS

ILLINOIS VALLEY COMMUNITY COLLEGE (Purchasing Department) 815 N. Orlando Smith Ave. Oglesby, Illinois REQUEST FOR PROPOSAL

TEL

Item No. Item Description Qty Ord Unit Price Ext. Price SE-6065-SS WING SCREW, 1/4"-20, SS, DISCONNECT DOOR 1 $ $ 4.00

DIRECTORATE OF CIVIL AVIATION

AUTOMATIC CONTROL VALVES Suggested List Price Effective April 6, 2015 (Rev: 2)

CAPTIVUE SPORTS MESSAGE CENTER INSTRUCTION MANUAL REVISION DATE: PART#:

FILED: NEW YORK COUNTY CLERK 07/13/ :02 PM INDEX NO /2016 NYSCEF DOC. NO. 1 RECEIVED NYSCEF: 07/13/2016

Rail Clamps Type BSZ. PINTSCH BUBENZER is certified according to DIN EN ISO 9001:2008. Safe Tried and Trusted High Performance Robust Easy Maintenance

Transcription:

R-407C REFRIGERANT OUTDOOR AIR-COOLED REMOTE CONDENSERS STANDARD FEATURES VERTICAL DISCHARGE WEATHER-TIGHT ELECTRICAL ENCLOSURE COMPUTER DESIGNED CONDENSER COILS FULL-FLOODING SYSTEM (-20 F CAPABILITY) FULLY ASSEMBLED ON HEAVY SKIDS CABINETS Designed for outdoor installation and constructed from heavy embossed aluminum with galvanized steel frame and legs. All fans shown in this guide are single row wide with double wide as a non-stocked option. Cabinets can be set up in a vertical or horizontal discharge configuration. FAN MOTORS Continuous duty, permanently lubricated, sealed ball bearing with automatic reset thermal overload protection. Single and three phase models available on most units. Direct drive fan motors feature patent-pending Service Ease tm motor mount system. DEFINITION OF QUIET AND STANDARD REMOTE CONDENSERS It is strongly recommended that where there is a choice of STANDARD and QUIET models shown that the QUIET model be selected where low operating sound is necessary such as all hotel and motel applications or where operating noise can impact personal quality of life. LORC-850 (850RPM) and all LNQ (540RPM), LNL (830 RPM) and LNX (830 RPM) models are quiet models. The balance of the LORC and LNH models exhibit standard commercial operating sound characteristics. As a bonus these condensers are also the most energy efficient available. CONDENSER COILS Feature the patented Floating Tube tm designed to virtually eliminate tube sheet leaks. Internal baffles are provided between all fan cells. Condensers up to 3 fans in length use 3/8 diameter tube to minimize refrigerant charge. Condensers using 4 or more fans in length use 1/2 diameter to minimize refrigerant pressure drop. Condensers shown will utilize fin spacing between 8 and 12 fins per inch depending on the model. 18 gauge galvanized steel casing and.808 inch aluminum tube sheets with fins Mechanically expanded into 3/8 and 1/2 copper tubes. FAN BLADES Patented QuietEdge tm technology is used throughout for improved sound performance. Dynamically balanced propeller blades with painted steel hubs and two set screws spaced 90 degrees apart. Fan guards are close meshed steel wire with a vinyl coating. ELECTRICAL ENCLOSURES All models are equipped with a weather-tight electrical enclosure containing the contactor or contactors and terminal board. Units with two or more fans also have fan cycle controls in the electrical box. CERTIFICATION All remote condensers are tested to exacting safety standards and are listed by Underwriter Laboratories for United States and Canadian installations.

ELECTRICAL DATA AND GENERAL INFORMATION DCA Model Numbers Circuits(s) S-Single D-Dual Number of Connections Connections Supply O.D. Return O.D. No. Of Fans 208/230 1 PH MCA / MOPD 208/230 3 PH 460 3 PH Approx. Shipping Weight Approx. Operating Weight LORC-1.5 S 1 each 5/8 5/8 1 15.0/15 15.0/15 15.0/15 96 77 LORC-2 S 1 each 7/8 5/8 1 15.0/15 15.0/15 15.0/15 96 77 LORC-3 S 1 each 7/8 5/8 1 15.0/15 15.0/15 15.0/15 96 81 LORC-4 S 1 each 7/8 5/8 1 15.0/15 15.0/15 15.0/15 135 125 LORC-5 S 1 each 1 1/8 7/8 1 15.0/15 15.0/15 15.0/15 320 195 LORC-5-850 S 1 each 1 1/8 7/8 1 15.0/15 N/A N/A 320 195 LORC-5R-850 S 1 each 1 1/8 7/8 1 15.0/15 N/A N/A 320 195 LORC-8 S 1 each 1 1/8 7/8 1 15.0/15 15.0/15 15.0/15 390 280 LORC-8-850 S 1 each 1 1/8 7/8 1 3.5/15 N/A N/A 390 280 LORC-10 S 1 each 1 3/8 1 1/8 2 15.0/15 15.0/15 15.0/15 520 475 LORC-10-850 S 1 each 1 3/8 1 1/8 2 15.0/15 N/A N/A 520 475 LORC-12 S 1 each 1 3/8 1 1/8 2 15.0/15 15.0/15 15.0/15 520 495 LORC-12-850 S 1 each 1 3/8 1 1/8 2 6.3/15 N/A N/A 520 495 LORC-14 S 1 each 1 3/8 1 1/8 2 15.0/15 15.0/15 15.0/15 650 540 LORC-14-850 S 1 each 1 3/8 1 1/8 2 6.3/15 N/A N/A 650 540 LORC-16 S 1 each 1 3/8 1 1/8 2 15.0/15 15.0/15 15.0/15 680 575 LORC-16-850 S 1 each 1 3/8 1 1/8 2 6.3/15 N/A N/A 680 575 LORC-21 S 1 each 2 1/8 1 3/8 3 15.0/15 15.0/15 15.0/15 D 2 each 1 5/8 1 1/8 3 15.0/15 15.0/15 15.0/15 716 600 LORC-21-850 S 1 each 2 1/8 1 3/8 3 9.1/15 N/A N/A 716 600 LORC-23 S 1 each 2 1/8 1 3/8 3 15.0/15 15.0/15 15.0/15 780 650 LORC-23-850 S 1 each 2 1/8 1 3/8 3 9.1/15 N/A N/A 780 650 LORC-26 D 2 each 1 5/8 1 1/8 3 15.0/15 15.0/15 15.0/15 840 675 LORC-26-850 S 1 each 2 1/8 1 3/8 3 9.1/15 N/A N/A D 2 each 1 5/8 1 1/8 3 9.1/15 N/A N/A 840 675 LNQ-S01-A005-10 S 1 each 1 3/8 1 3/8 1 N/A 15.0/15 15.0/15 460 350 LNQ-S01-A006-10 S 1 each 1 3/8 1 3/8 1 N/A 15.0/15 15.0/15 480 385 LNH-S01-A009-10 S 1 each 1 3/8 1 3/8 1 N/A 15.0/25 15.0/15 480 385 LNH-S02-A011-10 D 1 each 1 1/8 1 1/8 2 N/A 20.0/35 15.0/15 760 605 LNH-S02-A015-10 S 1 each 1 3/8 1 3/8 2 N/A 20.0/35 15.0/15 810 670 LNH-S02-A017-10 D 2 each 1 5/8 1 5/8 2 N/A 20.0/35 15.0/15 860 755 LNH-S03-A022-10 D 2 each 1 5/8 1 5/8 3 N/A 22.8/40 15.0/20 1170 1040 LNL-S01-A007-10 S 1 each 1 3/8 1 3/8 1 N/A 15.0/25 15.0/15 460 350 LNL-S02-A010-10 S 1 each 1 3/8 1 3/8 2 N/A 15.0/30 15.0/15 760 605 LNL-S02-A014-10 D 2 each 1 3/8 1 3/8 2 N/A 15.0/30 15.0/15 810 670 LNL-S02-A016-10 D 2 each 1 5/8 1 5/8 2 N/A 15.0/30 15.0/15 860 755 LNL-S03-A021-10 D 2 each 1 5/8 1 5/8 3 N/A 21.5/35 15.0/15 1170 1040 LNL-S03-A024-10 D 2 each 1 5/8 1 5/8 3 N/A 21.5/35 15.0/15 1240 1075 LNX-S01-A006-10 S 1 each 1 3/8 1 3/8 1 N/A 15.0/15 15.0/15 460 350 LNX-S01-A008-10 S 1 each 1 3/8 1 3/8 1 N/A 15.0/15 15.0/15 480 385 LNX-S02-A010-10 S 1 each 1 3/8 1 3/8 2 N/A 15.0/20 15.0/15 760 605 LNX-S02-A013-10 S 1 each 1 5/8 1 5/8 2 N/A 15.0/20 15.0/15 D 2 each 1 3/8 1 3/8 2 N/A 15.0/20 15.0/15 810 670 LNX-S02-A015-10 S 1 each 2 1/8 2 1/8 2 N/A 15.0/20 15.0/15 D 2 each 1 5/8 1 5/8 2 N/A 15.0/20 15.0/15 860 755 LNX-S03-A020-10 D 2 each 1 5/8 1 5/8 3 N/A 20.0/15 15.0/15 1170 1040 LNX-S03-A023-10 D 2 each 1 5/8 1 5/8 3 N/A 20.0/15 15.0/15 1420 1290

OUTDOOR AIR-COOLED CONDENSERSHUMIDIFIER CONDENSER SELECTION GUIDE DCA MODEL LINE SIZE (O.D.) AMBIENT MODEL PHASE NUMBER SUPPLY RETURN 95ºF 100ºF 105ºF DCA 650T / DCA 650TWH STANDARD 5/8 3/8 1 LORC-1.5 LORC-2 LORC-3 DCA 900T / DCA 900TWH STANDARD 5/8 3/8 1&3 LORC-3 LORC-3 LORC-4 DCA 1500T / DCA 1500TWH STANDARD 3/4 1/2 1 LORC-4 LORC-5 LORC-8 STANDARD 3/4 1/2 3 LORC-4 LORC-5 LNQ-S01-A005-10 QUIET 3/4 1/2 1 LORC-5-850 LORC-5R-850 LORC-8-850 QUIET 3/4 1/2 3 N/A N/A LNQ-S01-A005-10 DCA 2000T / DCA 2000TWH STANDARD 3/4 1/2 1 LORC-5 LORC-8 LORC-8 STANDARD 3/4 1/2 3 LORC-5 LNQ-S01-A005-10 LNQ-S01-A005-10 QUIET 3/4 1/2 1 LORC-5R-850 LORC-8-850 LORC-10-850 QUIET 3/4 1/2 3 N/A LNQ-S01-A005-10 LNQ-S01-A005-10 DCA 2500T / DCA 2500TWH STANDARD 7/8 1/2 1 LORC-8 LORC-8 LORC-12 STANDARD 7/8 1/2 3 LNQ-S01-A005-10 LNQ-S01-A005-10 LNX-S01-A006-10 QUIET 7/8 1/2 1 LORC-8-850 LORC-10-850 LORC-12-850 QUIET 7/8 1/2 3 LNQ-S01-A005-10 LNQ-S01-A005-10 LNQ-S01-A006-10 DCA 3000T / DCA 3000TWH STANDARD 7/8 5/8 1 LORC-8 LORC-8 LORC-10 STANDARD 7/8 5/8 3 LNQ-S01-A005-10 LNQ-S01-A005-10 LNX-S01-A006-10 QUIET 7/8 5/8 1 LORC-8-850 LORC-10-850 LORC-12-850 QUIET 7/8 5/8 3 LNQ-S01-A005-10 LNQ-S01-A005-10 LNQ-S01-A006-10 DCA 3300T / DCA 3300TWH STANDARD 7/8 5/8 1 LORC-8 LORC-10 LORC-14 STANDARD 7/8 5/8 3 LNX-S01-A006-10 LNX-S01-A006-10 LNL-S01-A007-10 QUIET 7/8 5/8 1 LORC-10-850 LORC-12-850 LORC-16-850 QUIET 7/8 5/8 3 LNQ-S01-A006-10 LNQ-S01-A006-10 LNX-S01-A008-10 DCA 3600T / DCA 3600TWH STANDARD 1 1/8 5/8 1 LORC-10 LORC-12 LORC-16 STANDARD 1 1/8 5/8 3 LNX-S01-A006-10 LNX-S01-A006-10 LNX-S01-A008-10 QUIET 1 1/8 5/8 1 LORC-12-850 LORC-14-850 LORC-21-850 QUIET 1 1/8 5/8 3 LNQ-S01-A006-10 LNX-S01-A006-10 LNX-S01-A008-10 DCA 4100T / DCA 4100TWH STANDARD 1 1/8 5/8 1 LORC-12 LORC-14 LORC-16 STANDARD 1 1/8 5/8 3 LNX-S01-A008-10 LNX-S01-A008-10 LNH-S01-A009-10 QUIET 1 1/8 5/8 1 LORC-14-850 LORC-16-850 LORC-21-850 QUIET 1 1/8 5/8 3 LNX-S01-A008-10 LNX-S01-A008-10 LNX-S02-A010-10

OUTDOOR AIR-COOLED CONDENSERSHUMIDIFIER CONDENSER SELECTION GUIDE DCA MODEL LINE SIZE (O.D.) AMBIENT MODEL PHASE NUMBER SUPPLY RETURN 95ºF 100ºF 105ºF DCA 4800T / DCA 4800TWH STANDARD 1 1/8 3/4 1 LORC-14 LORC-16 LORC-21 STANDARD 1 1/8 3/4 3 LNX-S01-A008-10 LNX-S01-A008-10 LNL-S02-A010-10 QUIET 1 1/8 3/4 1 LORC-16-850 LORC-21-850 LORC-26-850 QUIET 1 1/8 3/4 3 LNX-S01-A008-10 LNX-S01-A008-10 LNX-S02-A010-10 DCA 5500T / DCA 5500TWH STANDARD 1 1/8 7/8 1 LORC-14 LORC-21 LORC-23 STANDARD 1 1/8 7/8 3 LNX-S01-A008-10 LNL-S02-A010-10 LNX-S02-A013-10 QUIET 1 1/8 7/8 1 LORC-21-850 LORC-21-850 N/A QUIET 1 1/8 7/8 3 LNX-S01-A008-10 LNX-S02-A010-10 LNX-S02-A013-10 DCA 7000T / DCA 7000TWH STANDARD 1 3/8 7/8 1 LORC-21 LORC-23 N/A STANDARD 1 3/8 7/8 3 LNL-S02-A010-10 LNX-S02-A013-10 LNH-S02-A015-10 QUIET 1 3/8 7/8 1 LORC-23-850 LORC-26-850 N/A QUIET 1 3/8 7/8 3 LNX-S02-A010-10 LNX-S02-A013-10 LNX-S02-A015-10 DCA 8000T STANDARD (2) 1 1/8 (2) 5/8 1 LORC-21 LORC-26 N/A STANDARD (2) 1 1/8 (2) 5/8 3 LNH-S02-A011-10 LNL-S02-A014-10 LNH-S02-A017-10 QUIET (2) 1 1/8 (2) 5/8 1 LORC-26-850 N/A N/A QUIET (2) 1 1/8 (2) 5/8 3 LNX-S02-A013-10 LNX-S02-A015-10 LNX-S03-A020-10 DCA 9000T STANDARD (2) 1 1/8 (2) 3/4 1 LORC-26 N/A N/A STANDARD (2) 1 1/8 (2) 3/4 3 LNL-S02-A014-10 LNL-S02-A016-10 LNH-S03-A022-10 QUIET (2) 1 1/8 (2) 3/4 1 N/A N/A N/A QUIET (2) 1 1/8 (2) 3/4 3 LNL-S02-A014-10 LNL-S02-A016-10 LNX-S03-A023-10 DCA 11000T STANDARD (2) 1 1/8 (2) 7/8 1 N/A N/A N/A STANDARD (2) 1 1/8 (2) 7/8 3 LNX-S02-A015-10 LNL-S03-A021-10 LNL-S03-A024-10 QUIET (2) 1 1/8 (2) 7/8 1 N/A N/A N/A QUIET (2) 1 1/8 (2) 7/8 3 LNX-S02-A015-10 LNX-S03-A020-10 LNL-S03-A024-10 DCA 14000T STANDARD (2) 1 3/8 (2) 7/8 1 N/A N/A N/A STANDARD (2) 1 3/8 (2) 7/8 3 LNL-S03-A021-10 LNL-S03-A024-10 CONTACT FACTORY QUIET (2) 1 3/8 (2) 7/8 1 N/A N/A N/A QUIET (2) 1 3/8 (2) 7/8 3 LNX-S03-A020-10 LNX-S03-A023-10 CONTACT FACTORY

CONDENSER DIMENSIONS General Fan Layouts Model LORC 1-8 Model LORC 10-16 Model LORC 21-26 1 2 1 2 3 Dimensions for models LORC 1-4 2 7/16" 22" 8" 27 5/8" (35 5/8" LORC 4 Only) 15 1/4" 7/16" Diameter Hole 9/16" 34 1/4" 2" 18" 2" (41 1/4" LORC 4 Only) 22" 37 1/2" (47 1/2" LORC 4 Only) 13/32" x 1/2" Slots Unit legs are removable from units installed for horizontal air Dimensions for models LORC 5-26 Vertical Airflow 43" A DIMENSIONS LORC A B 5 40 30 8 50 40 10 70 60 12 70 60 14 90 80 16 90 80 21 130 120 23 130 120 26 130 120 Optional External Electrical Box 24 1/2" 16" 17" 34" 9" B 1" 21 1/2" 7/8" Diameter Holes 8" Dimensions for models LORC 5-26 Horizontal Airflow 43" 2 1/2" 37 1/2" 42 1/2" 7/8" Diameter Holes 9" B A 1"

OUTDOOR AIR-COOLED CONDENSERSHUMIDIFIER CONDENSER DIMENSIONS CONTINUED Dimensions for all LNH, LNL, LNQ & LNX models with one fan End View Side View 45.43" 73" 42.43" Air Flow 49.13" 20.25".875" DIA. MTG. HOLES TYP. 38" 53" 59" Dimensions for all LNH, LNL, LNQ & LNX models with two fans End View Side View 45.43" 127" 42.43" Air Flow 49.13" 20.25".875" DIA. MTG. HOLES TYP. 38" 106" 112" Dimensions for all LNH, LNL, LNQ & LNX models with three fans End View Side View 45.43" 180" 42.43" Air Flow 49.13" 20.25".875" DIA. MTG. HOLES TYP. 38" Note: Double row of fans available upon request. 53" 53" 53" 165"