Southern California Edison s Renewable Auction Mechanism (RAM) Program. June 6, 2014 EPRG Workshop on Distributed Generation and Smart Connections

Similar documents
2013 RPS Solicitation Request for Proposals Conference. January 13, 2014

PG&E s Bidders Webinar

Bioenergy Renewable Auction Mechanism (BioRAM) Request for Offers

ADVICE LETTER (AL) SUSPENSION NOTICE ENERGY DIVISION

PG&E s Bidders Webinar

SUBJECT: Submission of the Tule Wind Contract for Procurement of Renewable Energy from SCEs 2014 Renewables Portfolio Standard Solicitation

APPENDIX D POWER PURCHASE AGREEMENT COVER SHEET

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA

POWER PURCHASE AGREEMENT COVER SHEET

RENEWABLE MARKET ADJUSTING TARIFF POWER PURCHASE AGREEMENT

December 5, 2016 Advice Letter 3501-E

SUBJECT: Submission of the Sun Streams Contract for Procurement of Renewable Energy from SCEs 2014 Renewables Portfolio Standard Solicitation

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA. And Related Matters. Application Application

Request for Offers. July 17, Subject: PG&E s Request for Offers ( RFO ) for 2014 Resource Adequacy ( RA ) and Import Energy

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

SOUTHERN CALIFORNIA EDISON COMPANY S (U 338-E) 2011 RENEWABLES PORTFOLIO STANDARD PROCUREMENT PLAN VOLUME 1

Smart Grid Compressed Air Energy Storage Demonstration Project Request for Offers

ELECTRIC SCHEDULE E-CHP Sheet 1 (N) COMBINED HEAT AND POWER PPA

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA

SOUTHERN CALIFORNIA EDISON COMPANY S (U 338-E) AMENDED 2011 RENEWABLES PORTFOLIO STANDARD PROCUREMENT PLAN VOLUME 1

PENINSULA CLEAN ENERGY JPA Board Correspondence

This memo provides highlights of market performance in October and November.

Flexible Capacity Procurement. Market and Infrastructure Policy Issue Paper

Amendment to extend exceptional dispatch mitigated energy settlement rules and modify residual imbalance energy settlement rules

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

ELECTRIC SCHEDULE E-CHPSA Sheet 1 (N) COMBINED HEAT AND POWER SIMPLIFIED UNDER 500 KW PPA

California Independent System Operator Corporation Fifth Replacement Electronic Tariff

California Independent System Operator Corporation Fifth Replacement Electronic Tariff

We Energies. Request for Proposal Renewable Energy Supply 2014

August 25, Advice Letter 4677-E

POWER PURCHASE AND SALE AGREEMENT. between [BUYER S NAME] and [SELLER S NAME] (ID #[Number])

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

Marin Clean Energy 2016 Open Season Procurement Process Procedural Overview & Instructions

BIOENERGY MARKET ADJUSTING TARIFF POWER PURCHASE AGREEMENT

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA CLEAN COALITION COMMENTS ON THIRD REVISED POWER PURCHASE AGREEMENT

SUBJECT: Submission of the Garland Contract for Procurement of Renewable Energy from SCE's 2014 RPS Solicitation

1 Demand Response Auction Mechanism Q & A

SUBJECT: Submission of Contract for Procurement of Renewable Energy from SCE's 2013 Renewables Portfolio Standard Solicitation

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

SUBJECT: Submission of Contract for Procurement of Renewable Energy from SCE's 2013 Renewables Portfolio Standard Solicitation

California Independent System Operator Corporation Fifth Replacement Electronic Tariff

California ISO. Q Report on Market Issues and Performance. August 22, Prepared by: Department of Market Monitoring

MARIN ENERGY AUTHORITY REQUEST FOR PROPOSALS

Advice Letters 2311-E and 2311-E-A

August 15, 2016 PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA ENERGY DIVISION

CITY OF DANA POINT. FINANCIAL REVIEW COMMITTEE Agenda Report

Request for Proposals. Renewable Resources (2016R RFP) ISSUED: Monday, April 11, DUE DATE: Friday, May 20, :00 PM PPT

SUBJECT: Submission of Contract for Procurement of Renewable Energy from SCE's 2013 Renewables Portfolio Standard Solicitation

Pursuant to Rules 211, 213, and 214 of the Rules and Regulations of the Federal

LANCASTER CHOICE ENERGY

Dominion Energy Virginia

Clean Coalition comments on Proposed CREST PPA

Schedule NEM-V-ST Sheet 1 VIRTUAL NET METERING FOR MULTI-TENANT AND MULTI-METER PROPERTIES SUCCESSOR TARIFF

Installed Capacity (ICAP) Market Introduction

83C Questions and Answers

June 13, Advice Letter 3884-E

Regulation Director FERC Rates & Regulation. January 27, 2012

ADVICE LETTER (AL) SUSPENSION NOTICE ENERGY DIVISION

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Original Cal. PUC Sheet No E.

Stakeholder Comments Template

TAC FIX IMPACT MODEL DETAILED OVERVIEW

Schedule GTSR-CR Sheet 1 GREEN TARIFF SHARED RENEWABLES COMMUNITY RENEWABLES

Business Overview. Jim Scilacci Senior VP and CFO, Edison Mission Group. Lehman Brothers High Yield Bond and Syndicated Loan Conference

Testimony of Southern California Edison Company in Support of Its 2018 Energy Storage Procurement and Investment Plan

Qualifying Facility Avoided Cost Procedures

Schedule GTSR-GR Sheet 1 GREEN TARIFF SHARED RENEWABLES GREEN RATE

Solicitation Protocol

UNITED STATES OF AMERICA BEFORE THE FEDERAL ENERGY REGULATORY COMMISSION SAN DIEGO GAS & ELECTRIC COMPANY ) DOCKET NO.

VCE Board Meeting. May 10, 2018 Woodland City Council Chambers

Georgia Power Company s Qualifying Facilities (QF) Fundamentals

UNITED STATES OF AMERICA 117 FERC 61,356 FEDERAL ENERGY REGULATORY COMMISSION

April 6, 2016 Advice Letter: 4803-E

Akbar Jazayeri Vice President, Regulatory Operations Southern California Edison Company P O Box 800 Rosemead, CA 91770

Prototype Wind PPA Term Sheet

2018 Interconnection Process Enhancements (IPE) Stakeholder Call May 21, :00 a.m. 4:00 p.m. (Pacific Time)

Stakeholder Process: Congestion Revenue Rights Auction Efficiency. Summary of Submitted Comments

83D Questions and Answers

ISO Transmission Planning Process. Supplemental Sensitivity Analysis: Risks of early economic retirement of gas fleet

SCHEDULE 85 COGENERATION AND SMALL POWER PRODUCTION STANDARD CONTRACT RATES

CCE3 Workshop: DRAM Pilots

First Revision of Sheet No P.S.C.U. No. 50 Canceling Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO.

IR Application Generator Facility Data Form Overview

RE: Southern California Edison Company s Formula Transmission Rate Annual Update Filing in Docket No. ER (TO11)

Russell G. Worden Director, Regulatory Operations Southern California Edison Company 8631 Rush Street Rosemead, CA 91770

D Los Angeles ""VV Department of

August 15, 2016 PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA ENERGY DIVISION

Review of LADWP Feed-In-Tariff Proposal for City Council

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

Southern California Edison Company

OREGON STANDARD AVOIDED COST RATES AVOIDED COST PURCHASES FROM ELIGIBLE QUALIFYING FACILITIES Page 1

The Effective Date of E-BioMAT is November 18, 2015, as determined in CPUC D

Energy Resource Recovery Account (ERRA) 2018 Forecast of Operations Rebuttal Testimony Public Version

THE NARRAGANSETT ELECTRIC COMPANY RENEWABLE ENERGY GROWTH PROGRAM FOR NON-RESIDENTIAL CUSTOMERS

ATTACHMENT Q PJM CREDIT POLICY

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA REPLY COMMENTS OF THE CALIFORNIA INDEPENDENT SYSTEM OPERATOR CORPORATION

Oregon John A. Kitzhaber, MD, Governor

Community Solar Rate Rider: Schedule No February 13, 2018

Transcription:

Southern California Edison s Renewable Auction Mechanism (RAM) Program June 6, 2014 EPRG Workshop on Distributed Generation and Smart Connections

The RAM Contracting Tool In D.10-12-048 ( the RAM Decision ), the California Public Utilities Commission ( CPUC ) adopted a new contracting tool called the Renewable Auction Mechanism, or RAM To procure eligible renewable resources from generating facilities not greater than 20 megawatts (MW) Located within one of the California investor-owned utilities (IOU) service territories Southern California Edison (SCE) Pacific Gas and Electric (PG&E) San Diego Gas and Electric (SDG&E) RAM uses a standard non-negotiable power purchase agreement (PPA) SCE is required to procure 754.4 MW in three separate resource categories Peaking, as-available (e.g., solar) Non-peaking, as-available (e.g., wind) Baseload (e.g., geothermal, biomass) Offers must be evaluated and ranked separately within each category, based on price, plus transmission adder, minus resource adequacy benefits ( PTAR ) Page: 1

RAM Contracting a Six Month Process RFO Auction Date COD 1, Months after CPUC Approval 1 November 15, 2011 18 2 2 May 31, 2012 24 2 3 December 21, 2012 24 2 4 June 28, 2013 24 2 1 Commercial Operation Deadline required in the RAM PPA 2 RAM PPA allows for a 6-month extension in the event of regulatory delays beyond Seller s control Page: 2

RAM 1 through RAM 4 A Competitive Market Offers contracted, in terms of both number of offers and megawatts, have been a small percentage of offers received Ten percent or less in each RAM auction These results provide a good indication of a competitive market RAM 1 RAM 2 RAM 3 RAM 4 # MW # MW # MW # MW Offers 92 1,260 142 2,133 130 1,928 126 2,021 PPAs 7 67 6 97 13 202 10 164 PPAs, % of Offers 8% 5% 4% 5% 10% 10% 8% 8% Page: 3

RAM 4 Offer Locations Page: 4

RAM Resource Categories SCE has procured within resource categories as ordered in the RAM Decision The market has been dominated by solar PV offers Therefore, SCE established targets (±20 MW) that allowed up to 100% of the selected offers to be in the peaking, as-available category Number of MW in PPAs Executed, by Resource Category Resource Category RAM 1 RAM 2 RAM 3 RAM 4 Peaking, as-available executed MW 67 97 194 128 Non-peaking, as-available executed MW 0 0 7.5 35.8 Baseload executed MW 0 0 0 0 Total executed MW 67 97 201.5 163.8 Page: 5

Eligibility Criteria for Screening Offers RAM 5 The Generating Facility must be an eligible renewable resource, 3 to 20 MW The project has received a complete System Impact Study or Phase I Interconnection study, or passed Fast Track screens Offeror s interconnection study supports an interconnection date on or before December 1, 2016 Forecasted Commercial Operation Date is on or before December 1, 2016 The Site is within SCE s, PG&E s, or SDG&E s service territory An existing project, if currently under contract to SCE, PG&E or SDG&E, is eligible if the facility s existing contract term is scheduled to expire by December 1, 2016 Site control; team development experience; commercialized technology SCE affiliation is disclosed, if applicable Offeror agrees to non-disclosure requirements in the NDA Offeror has provided other information requested by SCE Page: 6

RAM Eligibility Screening - Experience Large numbers of offers were screened out during each procurement The primary reason was failure to demonstrate the ability to meet the required COD (which was 18 months in RAM 1; 24 months in RAM 2-4) Based on interconnection studies and milestone schedules submitted with the offer Other reasons amounted to failure to provide conforming documentation to support the offer (e.g., interconnection study) Offerors were given the opportunity to cure RAM 1 RAM 2 RAM 3 RAM 4 # Offers 92 142 130 126 # Screened Out for COD 45 22 16 30 # Screened Out for Other Reasons 1 7 21 16 Total # Screened Out 46 29 37 46 Percentage of Offers Screened Out 50% 20% 28% 37% Page: 7

Offer Price Assumptions The Offer Price must be developed with consistent assumptions. Offer Price must assume the following: Grid Interconnection Costs Direct Assignment Costs Seller bears the Direct Assignment Costs because there is no reimbursement of these costs to Seller Network Upgrades Seller bears the cost of financing the Network Upgrades* (unless the upgrades are pre-funded and such pre-funding has been approved by the CPUC) Awards Production Tax Credits, Investment Tax Credits and all other awards that Seller reasonably expects to apply Payments will be adjusted in each time of delivery ( TOD ) period by the Product Payment Allocation Factors set forth in the RAM PPA Energy-only ( EO ) TOD Factors apply when the project is interconnected as EO or if the project is bid as EO Full Capacity Deliverability Status ( FCDS ) TOD Factors apply to projects bid as FCDS when the project FCDS date bid in the offer has occurred * Developer is entitled to repayment with interest over a 5 year period following initial operation. Interest will be calculated in accordance with FERC s regulations at 18 C.F.R. 35.19a(a)(2)(iii). Page: 8

Offer Price Assumptions (continued) The Offer Price must be developed with consistent assumptions. Offer Price must assume the following: TMY data Offeror must use TMY-3 data* in building the Generation Profile On the Generation Profile spreadsheet, Offeror must indicate the USAF Number (Station Number) that was used as the source of the TMY-3 data Hourly average data to represent all hours in a month are not acceptable Distribution loss factors ( DLFs ) Offer price should not include DLFs SCE will incorporate them as applicable Collateral requirements Development security Performance assurance SCE s Revenue Calculator will be provided as informational only Calculates revenue from energy generation profile Takes into account the TOD Periods and Product Payment Allocation Factors *The "TMY-3 data can be found on the NREL website at http://rredc.nrel.gov/solar/old_data/nsrdb/1991-2005/tmy3/. Page: 9

Resource Adequacy Offerors have the option to bid their project into the RAM 5 RFO based on EO or FCDS interconnection Offeror is not required to have applied for or obtained FCDS as a condition of submitting an Offer Only those projects that interconnect as FCDS or have been assigned deliverability are eligible to provide resource adequacy ( RA ) Each Offer must indicate whether it is based on an FCDS or EO interconnection, and, if interconnecting pursuant to FCDS, the Offer must indicate the date by which the Generating Facility will begin delivering Resource Adequacy ( RA Guarantee Date ) An Offeror can submit multiple Offers for the same Generating Facility, including separate Offers for EO and FCDS Offers based on FCDS will receive RA benefits in the evaluation RA benefits will only be credited for periods after the offered RA Guarantee Date Conversely, EO Offers will not receive any RA benefit in the evaluation Page: 10

Evaluation of Offers SCE will screen conforming Offers on a pass-fail basis against the eligibility criteria listed in the RAM 5 RFO Instructions SCE will rank eligible Offers based on the sum of levelized Product Price (TODadjusted) and estimated costs of Network Upgrades calculated from Offeror s interconnection study or interconnection agreement for the project, minus RA benefits Price plus Transmission Adder minus RA benefits ( PTAR ) in $/MWh Only Reliability Network Upgrades (RNUs) will be used to create the transmission adder for EO Offers Deliverability Network Upgrades (DNUs) and RNUs will be used for FCDS Offers Any non-competitive Offers or evidence of market manipulation will result in Offers being rejected Subject to previous bullet, ranking will start with the least expensive Offer based on PTAR until the capacity target in each bucket (plus or minus 20 MW) is reached, and the overall capacity target is reached Page: 11

Seller s Product Delivery Obligation Expected Annual Net Energy Production ( EANEP ): EANEP = Capacity x capacity factor x 8,760 hours per year Example: 10 MW wind project 25% capacity factor EANEP = 21,900 MWh/year Seller s Product Delivery Obligation for intermittent technologies is based on a percentage of the EANEP during the prior 24-month period 140% for Wind; 0% for Hydro; 160% all other intermittent technologies For baseload technologies, Seller s Energy Delivery Obligation for the twelve (12) month period immediately preceding the end of each Term Year commencing at the end of the second Term Year must equal 90% of the EANEP If Seller delivers less than its Product Delivery Obligation (except for certain excused amounts, such as Curtailed Product or Lost Output), it must pay a Product Replacement Damages Amount Page: 12

Further Information RAM 5 RFO website https://sceram.accionpower.com See especially the RFO Instructions in the Documents tab George Wiltsee: 626-302-4945; george.wiltsee@sce.com Page: 13