May 3, Dear Ms. Bordelon:

Similar documents
Entergy Arkansas, Inc Integrated Resource Plan. Follow-Up Materials June 18, 2018 entergy-arkansas.com/irp

SPO PLANNING ANALYSIS 2015 ENO IRP. Updates for the Final IRP SEPTEMBER 18, 2015

Power Accountants Association Annual Meeting Potential Impacts from Oct 2015 Rate Change

Quarterly Report to the Pennsylvania Public Utility Commission

For the Efficiency Maine Trust October 15, 2009 Eric Belliveau, Optimal Energy Inc.

Quarterly Report to the Pennsylvania Public Utility Commission

2019 Integrated Resource Plan (IRP) Public Input Meeting January 24, 2019

STATEWIDE EVALUATION TEAM PRELIMINARY ANNUAL REPORT TO THE PENNSYLVANIA PUBLIC UTILITY COMMISSION

Exhibit DAS-1. Tucson Electric Power Company Demand-Side Management Program Portfolio Plan

STATEWIDE EVALUATION TEAM SEMI-ANNUAL REPORT

BEFORE THE ARKANSAS PUBLIC SERVICE COMMISSION DIRECT TESTIMONY LOVITA GRIFFIN, EEP RATE ANALYST

Quarterly Report to the Pennsylvania Public Utility Commission

Quarterly Report to the Pennsylvania Public Utility Commission

Annual Report to the Pennsylvania Public Utility Commission For the period December 2009 to May 2010 Program Year 2009

Updates & Milestones re: Peak Demand Reduction. EEAC Consultants (with PA contributions) (Revised, 3/13/17)

FIVE YEAR PLAN FOR ENERGY EFFICIENCY

BEFORE THE PENNSYLVANIA PUBLIC UTILITY COMMISSION

Quarterly Report to the Pennsylvania Public Utility Commission

WESTERN MASSACHUSETTS

Large Commercial Rate Simplification

Department of Market Monitoring White Paper. Potential Impacts of Lower Bid Price Floor and Contracts on Dispatch Flexibility from PIRP Resources

Natural Gas Avoided Cost Meeting. 10 a.m. 12 p.m. May 12, 2017

DUQUESNE LIGHT COMPANY PROGRAM YEAR 7 ANNUAL REPORT

APSC FILED Time: 3/31/ :15:35 AM: Recvd 3/31/ :13:45 AM: Docket tf-Doc. 231

NSTAR ELECTRIC COMPANY d/b/a EVERSOURCE ENERGY SUMMARY OF ELECTRIC SERVICE DELIVERY RATES. M.D.P.U. No E Page 1 of 10

Electric Avoided Cost Meeting. 1:30-3:30 p.m. May 12, 2017

SECOND QUARTER 2017 RESULTS. August 3, 2017

APSC FILED Time: 4/1/2014 1:00:19 PM: Recvd 4/1/ :52:33 PM: Docket tf-Doc. 196

Long-Term Reliability Assessment

NSTAR ELECTRIC COMPANY d/b/a EVERSOURCE ENERGY SUMMARY OF ELECTRIC SERVICE DELIVERY RATES. M.D.P.U. No C Page 1 of 10

HYDROELECTRIC INCENTIVE MECHANISM

Last change 1/1/19 1/1/19 1/1/19 1/1/19 1/1/19 1/1/19 1/1/19 3/1/98 7/1/18 7/1/18 1/1/03 1/1/19

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF COLORADO

Quarterly Report to the Pennsylvania Public Utility Commission

Prepared for the BC Sustainable Energy Association. Expanding Energy Efficiency for BC Hydro: Lessons from Industry Leaders.

REPORT TO THE PUBLIC UTILITIES BOARD

Price Inconsistency Market Enhancements. Revised Straw Proposal

Most Critical Factors Impacting Cost-Effectiveness of Feedback Programs

STATE OF MARYLAND OFFICE OF PEOPLE S COUNSEL. October 19, 2011

BEFORE THE NEW MEXICO PUBLIC REGULATION COMMISSION ) ) ) ) ) ) ) ) ) ) DIRECT TESTIMONY JANNELL E. MARKS. on behalf of

Installed Capacity (ICAP) Market

Mid-Term Modifications

Active Demand Reduction Cost-Effectiveness Considerations. PA Presentation for EEAC November 15, 2017

Managing Risk of a Power Generation Portfolio

ARR/FTR Market Update: ATC Customer Meeting. August 20, 2009

NSTAR ELECTRIC COMPANY d/b/a EVERSOURCE ENERGY SUMMARY OF ELECTRIC SERVICE DELIVERY RATES. M.D.P.U. No C Page 1 of 9

FDD FIRM STORAGE SERVICE NORTHERN NATURAL GAS COMPANY

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

0 IJifitil. j,j SEP. Respecifullysubmitted, ncosure. September 1 8, 2017 VIA ELECTRONIC FILING AND MAIL, \

N~ AMPSHIRE. Electric Co-op

New natural gas rates approved in 2018.

ATLANTIC CITY ELECTRIC COMPANY BPU NJ

Further information on mid-year tariff changes following the September 2010 Customer Seminars

MICHIGAN PUBLIC SERVICE COMMISSION Case No.: U-18411

CALIFORNIA ISO BASELINE ACCURACY ASSESSMENT. Principal authors. November 20, Josh Bode Adriana Ciccone

Long Run Marginal Cost (LRMC)

October 22, 2007 VIA HAND DELIVERY & ELECTRONIC MAIL

Flexible Capacity Requirements for 2019 through 2021

Demand-Side Management Annual Status Report Electric and Natural Gas Public Service Company of Colorado

Ameren Missouri MEEIA Energy Efficiency Plan

ENERGY EFFICIENCY AND

California ISO. Flexible Ramping Product Uncertainty Calculation and Implementation Issues. April 18, 2018

This report summarizes key market conditions, developments, and trends for November 2001.

September 30, Part Version Title V LNG Rates

August 24, The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, D.C.

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

Supplement No. 611 to P.S.C. Md. E-6: Rider 2 Electric Efficiency Charge, Rider 15 Demand Response Service Charge and Rider 26 Peak Time Rebate Charge

/s/ John L. Carley Assistant General Counsel

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

Additional Agenda. City of Mississauga. General Committee. Date June 27, 2018 Time 9:00 A.M. Location Council Chamber 2 nd Floor 300 City Centre Drive

California ISO October 1, 2002 Market Design Elements

January 25, The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, N.E. Washington, D.C.

2015 Load Impact Evaluation of Pacific Gas and Electric Company s Residential Time-Based Pricing Programs: Ex-Post and Ex-Ante Report.

ITC Midwest 2014 Attachment O True-Up Presentation. Presenter: David Grover Manager, Transmission Pricing July 8, 2015

NYISO s Compliance Filing to Order 745: Demand Response. Wholesale Energy Markets

The Impact of Dynamic Pricing on Low Income Customers

Semi-Annual Report to the Pennsylvania Public Utility Commission

2015 RATE DESIGN APPLICATION (RDA) TRANSMISSION SERVICE RATE (TSR) STRUCTURES WORKSHOP #1

Modeling and IRP Analysis of EE Resources in the Southwest

APPROVED February 27, 2018 DIRECTOR of PUBLIC UTILITY DIVISION

March 2019 ARP Rate Call Package

If there are any questions concerning this filing, please contact the undersigned.

Impact Evaluation of 2014 San Diego Gas & Electric Home Energy Reports Program (Final Report)

DUKE ENERGY FLORIDA, LLC (DEF) SUMMARY OF 2017 DEMAND SIDE MANAGEMENT ACHIEVEMENTS

2011 Budget Initial Stakeholder Call

Glacial Lakes Sanitary Sewer & Water District Utility Rate Study. Shelly Eldridge Ehlers Jeanne Vogt - Ehlers

Appendix B-2. Term Sheet for Tolling Agreements. for For

Asset Management and Energy Initiatives. Kathleen Berube Sustainable Development Manager

DOCKET NO. 13A-0773EG DIRECT TESTIMONY AND EXHIBITS OF LEE E. GABLER

August 18, 2016 NWN OPUC Advice No A/UG 312 SUPPLEMENT A (UM 1027)

Colorado PUC E-Filings System

Informational Filing of Midwest Independent Transmission System Operator, Inc. s Independent Market Monitor

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

Management Comments. February 12, 2015

Draft Small Customer Aggregation Program Rules

Revenue Requirement Application. 2004/05 and 2005/06. Volume 2. Appendix I. Power Smart 10-Year Plan

FOURTH QUARTER AND FULL-YEAR 2017 RESULTS. February 23, 2018

Akbar Jazayeri Vice President, Regulatory Operations Southern California Edison Company P O Box 800 Rosemead, CA 91770

How Ontario is Putting Conservation First

MAR 2017 JAN 2017 DEC 2016 FEB 2017 HOEP*

Transcription:

Entergy Services, Inc. 639 Loyola Avenue (70113) P.O. Box 61000 New Orleans, LA 70161-1000 Tel 504 576 4122 Fax 504 576 5579 Michael J. Plaisance Senior Counsel Legal Services - Regulatory May 3, 2018 Via Hand Delivery Ms. Terri Lemoine Bordelon Louisiana Public Service Commission Records and Recording Division Galvez Building, 12th Floor 602 North 5th Street Baton Rouge, LA 70802 RE: 2017 Integrated Resource Planning ( IRP ) Process for Entergy Louisiana, LLC Pursuant to the General Order No. R-30021, Dated April 20, 2012 LPSC Docket No. I-34694 Dear Ms. Bordelon: I have enclosed an original and three copies of Entergy Louisiana, LLC s Responses to IRP Stakeholder Questions raised during the April 19, 2018 Stakeholder Meeting and Updated DSM Potential Study presented by ICF in connection with the referenced matter. Please file an original and two copies into the record, and return a datestamped copy to our by hand courier. Should you have any questions regarding the enclosed document, please do not hesitate to contact me. Sincerely, MJP/ Enclosure Michael J. Plaisance cc: Official Service List (via electronic mail)

LPSC DOCKET NO. I-34694 ELL 2019 INTEGRATED RESOURCE PLAN ELL S RESPONSES TO APRIL 19, 2018 INFORMAL STAKEHOLDER QUESTIONS During the April 19, 2018 Integrated Resource Plan ( IRP ) stakeholder meeting ( Stakeholder Meeting ), a number of stakeholders posed questions to Entergy Louisiana, LLC ( ELL ) and its consultant, ICF. ELL hereby provides responses to those questions that were not fully answered at the Stakeholder Meeting or otherwise merit further response: 1 1. ELL was asked which, if any, planned Midcontinent Independent System Operator, Inc. ( MISO ) Transmission Expansion Plan ( MTEP ) projects were included in ELL s IRP modeling. ELL s IRP modeling in the AURORA model uses a simplified zonal construct in which separate zones are modeled for the South (which includes Louisiana, Texas, Mississippi, and Arkansas), Central, and North regions of MISO. Transmission limitations are represented by the transfer capability between these zones, and no transmission limitations are modeled within each zone. The transfer limit between MISO South and MISO North/Central is based on a contractual agreement and is held constant throughout the IRP study period. 2. Stakeholders requested an explanation for the shape of the historical load curve on slide 8 of ELL s presentation. As part of ELL s load forecasting process, historical load data is weather normalized. In other words, ELL s historical load data is adjusted to a normal level based on whether the actual temperatures were higher or lower than normal. All of the loads shown on slide 8 (historical and forecasted peaks) are weathernormalized. August 2014 was a milder month than normal, and August 2015 was a significantly warmer month than normal. In the process of weather-normalizing those periods, the 2014 peak was adjusted upward, and the 2015 peak was adjusted downward, causing the dip shown in the chart on Slide 8. For reference, the actual peaks for 2014 and 2015 were 9.3 GW and 10.1 GW, respectively. 3. ELL was asked what factors contribute to ELL s projected load growth. ELL s peak and total load is forecasted to increase over time primarily due to increases in consumption from large industrial customers. Increasing load is also supported by expected increases in the numbers of residential and commercial customers but offset by expected decreases in average kwh usage for these residential and commercial customers. 4. A stakeholder asked if ELL s peak load data on slide 8 of ELL s presentation is the sum of the expected individual maximum load values of the various customer classes (e.g., commercial, residential, industrial) or the maximum load value of all customer classes 1 Because the Stakeholder Meeting was not transcribed, it is possible that the ELL did not capture all of the unanswered questions raised during the meeting.

combined. ELL responds that the peak load data (both forecasted and actual) is the maximum value of the total load for all of the customer classes taken as a whole. 5. A stakeholder asked if ELL s resource planning was done separately for the individual customer classes. ELL s resource planning decisions are generally based on ELL s total load from all customer classes. There are no explicit capacity requirements by class. Overall long-term capacity requirements are determined by adding a 12% installed capacity reserve margin to ELL s forecasted non-coincident peak load (for all customer classes in total). However, ELL has certain planning targets for types of capacity (e.g., baseload, peaking, etc.) based on its customers collective hourly load shape. If ELL had a different mix of industrial, commercial, and residential customers, then the resulting hourly load shape could result in different resource targets for ELL. 6. The Company notes that electric vehicle penetration was factored into the load forecast, the assumptions for the volumes of which in the near-term are very conservative. 7. The Company was asked to provide its deactivation assumptions by resource. Unitspecific deactivation assumptions are market sensitive information, and disclosure of such information to the market could negatively impact ELL and its customers. Aggregated annual deactivation assumptions are the greatest level of detail required to produce the supply deficit curves for the long-term supply need graphic on slide 9 of ELL s Data Assumptions presentation covered at the Stakeholder Meeting. Instead, ELL provides the aggregated annual deactivations in the table below. Table 1-2019 ELL IRP Supply Resource Deactivation Assumptions (Total MW by Year) 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 0 11 0 46 0 0 0 401 13 12 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 508 149 928 1,154 1,754 0 798 0 0 0 Notes: 1- MW values represent ELL s ownership share of the installed capacity ( ICAP ) of resources owned by ELL, based on the GVTC ratings effective for the 2018-2019 MISO Planning Year. 2- Deactivation assumptions are planning inputs based on age, criticality, reliability, and unit condition (both current and projected). These deactivation planning assumptions do not represent a deactivation schedule and are subject to change based on changes in unit condition, market condition, or economics. 8. During ICF s DSM Potential Study presentation, ICF was asked to provide assumptions behind time of use ( TOU ) rate designs and direct load control ( DLC ) measure and cost-effectiveness results for its Energy Efficiency and Demand Response program tests. ICF has provided an updated presentation that includes this information. The Company has attached this updated presentation, which has also been added to the Company s IRP website. 2

we are 2019 ELL IRP DSM Potential Study Approach and forecast April 19, 2018

Presentation Team Ali Bozorgi Project Manager Deputy Peter Lemoine Project Manager David Pudleiner Engineering and Modeling Lead 2

Energy Efficiency Approach Forecast Agenda Demand Response Approach Forecast 3

Energy Efficiency 4

Measure Cost- Effectiveness Screening (TRC ) Measure Savings, Cost, and Applicable Market Size Total Eligible Stock per Measure Measure Potential Utility and Measure Data Entergy Louisiana data New Orleans TRM and TRMs from other states EM&V reports / Program reports Current Programs Expanded Programs Payback Acceptance Market Diffusion Curves Inputs Incentive costs Non-Incentive Costs Net-to-Gross (NTG) ICF program implementation experience Benchmarking Study Outputs ELL Program Hourly Saving Profiles IRP Inputs: Hourly Saving Profiles Annual Program Costs Draft Report Final Report Energy efficiency potential study bottom-up approach 5

Energy efficiency scenarios modelled Current programs Current ELL programs were modelled largely based on current program designs, but with expanded budgets. Expanded programs Includes current programs plus new best practice programs. 6

Programs modelled Current Programs Lighting, Appliances and Electronics Residential HVAC and Tune-up Home Audit and Retrofit Low Income Weatherization Commercial Prescriptive and Custom Small Business Solutions Industrial Prescriptive and Custom Expanded (New) Programs ENERGY STAR New Homes Appliances Recycling Home Energy Use Benchmarking Midstream Commercial Lighting Commercial RetroCommissioning Commercial New Construction Industrial Strategic Energy Management 7

Annual savings could quadruple by 2023 Incremental (annual) MWh savings in ELL Program Year 2 (2015-16) (verified) and as forecasted for this study for 2023 2.9 x 2015-16 savings 4.2 x 2015-16 savings 8

Total (cumulative) savings could grow from ~50 GWh in 2019 to nearly 2,000 GWh by 2038 Net cumulative portfolio MWh savings 9

Industry is forecasted to account for 55% of load by 2038 A small fraction of industrial load is for end uses that are facility-related and not used for processes Distribution of ELL system load in 2038 (Total = 67 TWh) Commercial Goverment Industrial Residential 10

In the Expanded scenario residential and commercial sector level savings are about equal and together comprise 90% of total savings Net cumulative MWh savings by sector in 2038 11

Residential and commerical savings levels could reach up to 6.2% and 7.7% of sector sales, respectively, by 2038 Net cumulative MWh savings in 2038 as a % of MWh sales, by sector and in total 12

Whole home efficiency retrofits will replace lighting as the biggest residential savings opportunity new programs could increase sector savings by two-thirds Residential program savings in 2023 Note: Duct sealing is included in the HVAC and Tune-up program and in New Homes. Air sealing is included in Home Audit and Retrofit and in New Homes. Insulation is in the Home Audit and Retrofit program and in New Homes. 13

Net Cumulative MWh Savings Expanded programs could increase C&I savings by a third C&I program savings in 2023 350,000 Industrial Strategic Energy Management 300,000 250,000 Commercial New Construction 200,000 RetroCommissioning 150,000 Commercial Midstream Lighting 100,000 Industrial Prescriptive & Custom 50,000 Small Business Solutions 0 Current Expanded Commercial Prescriptive & Custom Note: Commercial Prescriptive & Custom savings are lower in the Expanded scenario because non-fixture lighting measures from that program were moved to the Midstream Lighting program for this scenario. 14

Cost and cost-effectiveness metrics Program Annual Program Costs (2018 $ mil) 2023 2028 2033 2038 Levelized $ / kwh TRC Test Lighting, Appliances and Electronics $ 1.0 $ 0.9 $ 0.9 $ 1.0 $ 0.04 1.7 HVAC and Tune-up $ 1.8 $ 1.8 $ 1.8 $ 1.8 $ 0.01 4.0 Home Audit and Retrofit $ 8.0 $ 8.1 $ 7.9 $ 7.7 $ 0.03 2.9 Low Income Weatherization $ 0.6 $ 0.7 $ 0.7 $ 0.7 $ 0.07 1.9 Total Residential Programs Current $ 11.4 $ 11.5 $ 11.3 $ 11.2 $ 0.03 3.0 ENERGY STAR New Homes $ 0.4 $ 1.6 $ 1.7 $ 1.7 $ 0.01 4.2 Appliances Recycling $ 2.3 $ 1.7 $ 1.9 $ 2.0 $ 0.03 1.9 Home Energy Use Benchmarking $ 0.4 $ 0.1 $ 0.2 $ 0.3 $ 0.02 5.1 Grand Total Residential Programs Expanded + Current $ 14.5 $ 15.0 $ 15.0 $ 15.2 $ 0.02 3.0 15

Cost and cost-effectiveness metrics Program Annual Program Costs (2018 $ mil) 2023 2028 2033 2038 Levelized $ / kwh TRC Test Small Business Solutions $ 3.2 $ 2.7 $ 2.3 $ 2.4 $ 0.02 2.2 Current Commercial Prescriptive & Custom $ 13.5 $ 13.0 $ 12.9 $ 12.9 $ 0.04 1.8 Total Commercial Programs - Current $ 16.6 $ 15.7 $ 15.2 $ 15.3 $ 0.03 1.9 RetroCommissioning $ 0.3 $ 0.3 $ 0.3 $ 0.3 $ 0.01 3.6 Commercial New Construction $ 0.7 $ 0.8 $ 0.8 $ 0.8 $ 0.01 2.3 Commercial Prescriptive & Custom $ 8.4 $ 8.7 $ 8.4 $ 8.4 $ 0.03 2.3 Midstream Commercial Lighting $ 7.0 $ 6.2 $ 6.2 $ 6.3 $ 0.06 1.1 Grand Total Commercial Programs Expanded + Current $ 19.6 $ 18.7 $ 18.1 $ 18.3 $ 0.03 1.9 Industrial Prescriptive & Custom $ 2.0 $ 2.0 $ 1.9 $ 1.8 $ 0.03 3.2 Industrial Programs - Current $ 2.0 $ 2.0 $ 1.9 $ 1.8 $ 0.03 3.2 Industrial Strategic Energy Management $ 0.6 $ 0.5 $ 0.5 $ 0.4 $ 0.03 3.3 Grand Total Industrial Programs Expanded + Current $ 2.6 $ 2.5 $ 2.3 $ 2.3 $ 0.03 3.2 Portfolio Total - Current $ 30.0 $ 29.2 $ 28.3 $ 28.3 $ 0.03 2.3 Portfolio Total - Expanded $ 36.7 $ 36.2 $ 35.5 $ 35.7 $ 0.03 2.4 16

Demand Response (DR) 17

Comprehensive List of DR Programs Program Selection Criteria Measure Cost- Effectiveness Screening (TRC ) Measure / Program Savings, Cost, and Applicable Market Size Total Eligible Stock per Measure / Program Measure Potential ICF TOURet Tool ICF DLC Tool Entergy Louisiana load data EM&V reports / Program reports from other states ICF Expert Judgment Benchmarking Reference Case Market Diffusion Curves Inputs Incentive Costs Non-Incentive Costs High Case ELL Program Hourly Saving Profiles Study Outputs Draft Report Demand response potential study bottom-up approach IRP Inputs: Hourly Saving Profiles Annual Program Costs Final Report 18

Different DR program types were initially assessed Dispatchable / Load Response Direct Load Control Interruptible Load Curtailable Load Automated DR Rate-based / Price Response Time-of-use pricing Critical peak pricing Real-time pricing Dispatchable - utility offers customers payments for reduction of demand during specified periods Rate-based - customers voluntarily reduce their demand in response to forward energy price signals Program selection for ELL based on ELL hourly load profile historic and forecasted (e.g. excluded CPP) Availability of data from programs across US, and Availability of required technologies for program implementation (e.g. excluded ADR and RTP) 19

5 DR programs (and 9 DLC measures) were selected to be modeled for this study Selected Programs to Model Time-of-Use Direct Load Control Class Residential Commercial Industrial Residential Commercial Time-of-Use Rate Evaluation Tool (ToURET) uses elasticity values and pricing assumptions to model consumer behavior in the form of energy shifts from peak to off-peak and consumption reductions within the same period Class Residential Commercial Measure Room AC Switch Central AC Switch Smart Thermostat Water Heater Switch Smart Appliances Battery Storage Central AC Switch Water Heater Switch Smart Thermostat Direct Load Control Tool uses historic and program information to quantify the impact of measures during the DR event period, and account for rebound or snap-back for the periods immediately following the DR event 20

7 DLC measures out of 9 DLC measures were included in achievable potential Class Residential Commercial Measure Room AC Switch Central AC Switch Smart Thermostat Water Heater Switch Smart Appliances Battery Storage Central AC Switch Water Heater Switch Cost-effectiveness screening (TRC) Class Residential Commercial Measure Room AC Switch Central AC Switch Smart Thermostat Water Heater Switch Central AC Switch Water Heater Switch Smart Thermostat Smart Thermostat 21

2 scenarios were developed for each program, Reference and High For Time-of-Use High and Reference cases were created to reflect different levels of pricing signals, specifically peak-to-off-peak price ratios and corresponding price elasticity assumptions For DLC Adoption rates and maximum achievable participation varied for the high and reference cases 22

Average Peak Reduction (MW) DR Programs can reduce the peak load in 2038 by 4% to 5% Average Summer Demand Reduction, by Scenario - Aggregate of All DR Programs 600.0 500.0 400.0 300.0 200.0 512 MW (5% of average peak load for 2038) 387 MW (4% of average peak load for 2038) 100.0 0.0 2019 2020 2021 2022 Note: demand savings are estimated based on the average annual summer peak savings 2023 2024 2025 2026 2027 2028 2029 Year Reference Case 2030 2031 2032 2033 2034 2035 High Case 2036 2037 2038 23

Average Peak Demand Savings (MW) Residential TOU, Residential DLC and Industrial TOU account for 85%+ of total DR potential in both cases 600.0 Annual DR Program Savings (Average Peak Demand) in 2038, by Program (MW) 500.0 400.0 300.0 200.0 100.0 0.0 Reference Case High Case DLC Residential ToU Residential ToU Industrial ToU Commercial DLC Commercial Note: demand savings are estimated based on the average annual summer peak savings 24

Residential costs dominate the total annual costs of implementing the DR programs Reference Case Cost of Implementation in $ mil Sector 2023 2028 2033 2038 Residential $ 0.8 $ 7.8 $ 7.8 $ 7.3 Commercial $ 0.3 $ 1.8 $ 1.6 $ 1.5 Industrial $ 0.1 $ 0.3 $ 0.6 $ 0.6 Total $ 1.2 $ 9.9 $ 9.9 $ 9.3 High Case Cost of Implementation in $ mil Sector 2023 2028 2033 2038 Residential $ 1.2 $ 7.5 $ 10.3 $ 9.4 Commercial $ 0.4 $ 1.7 $ 2.1 $ 1.8 Industrial $ 0.1 $ 0.3 $ 0.6 $ 0.7 Total $ 1.7 $ 9.5 $ 13.0 $ 11.9 25

Cost and cost-effectiveness metrics Program Type Sector Levelized Costs ($/kw) TRC Test (Cost-Benefit Ratio) Reference Case High Case Reference Case High Case Residential DLC Residential $76 $77 2.5 2.4 Residential ToU Residential $7 $7 13.1 15.1 Residential Subtotal $48 $42 3.7 4.1 Commercial DLC Commercial $97 $93 1.4 1.5 Commercial ToU Commercial $18 $14 5.6 7.1 Commercial Subtotal $67 $59 2.0 2.2 Industrial ToU Industrial $8 $7 13.1 13.8 Industrial Subtotal All DLC All ToU Total DR Portfolio $8 $7 13.1 13.8 $80 $80 2.2 2.2 $8 $7 11.7 13.2 $40 $37 3.9 4.3 26

Thank you! 27

Appendix 28

Incremental measure units Illustrative measure market adoption curve 60,000 50,000 40,000 30,000 20,000 10,000 Max participation Ramp-up period Max participation rate sustained - declining # units reflects shrinking eligible stock 0 2015 2020 2025 2030 2019 2023 2028 2038

Energy efficiency programs could offset up to a third of load growth ~24% load growth offset by EE programs by 2038 ~33% load growth offset by EE programs by 2038 Energy consumption (MWh) grows by 10% from 2019 to 2038. 30

Average Summer Peak Load (MW) Average Summer Peak Load (MW) DR programs could offset a major portion of ELL average summer peak demand growth by 2038 up to 41% in the reference case and 55% in the high case 41% of average peak demand growth offset by DR programs by 2038 55% of average peak demand growth offset by DR programs by 2038 Reference Case High Case 9,800 9,800 9,600 9,600 9,400 9,400 9,200 9,200 9,000 9,000 8,800 8,800 8,600 8,600 8,400 8,400 8,200 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 8,200 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 Post-Impact Load Reference Case DR Program Savings Post-Impact Load High Case DR Program Savings Average Summer Peak Load (MW) grows by 11% from 2019 to 2038. Note: Demand savings are estimated based on the average annual summer peak savings. 31

The residential sector has the largest peak load reduction potential for the DR programs AVERAGE PEAK LOAD (PRE- PROGRAM) DISTRIBUTION REFERENCE CASE 25% 45% 33% 13% 62% Residential Commercial Industrial 22% Program Impact by Sector HIGH CASE Total Residential Commercial 22% Share of Load and Program Impact by Sector, for 2038 13% 65% Residential Commercial Industrial 32

TOU Program Assumptions 33

Load (MW) Demand (MW) Load (MW) ELL Total load Forecasts Peaks and Daily Average Shapes 8,500 Average Hourly Load Shape for Winter Monthly Peak Load 8,000 11,000 10,500 7,500 7,000 2019 2023 10,000 6,500 2028 9,500 6,000 2033 9,000 2019 5,500 2038 8,500 8,000 7,500 7,000 6,500 2023 2028 2033 2038 5,000 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Hour of Day Average Hourly Load Shape for Summer 6,000 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Month Seasons based on monthly peaks for system load: Summer Jun, Jul, Aug 10,000 9,500 9,000 8,500 8,000 7,500 7,000 6,500 6,000 5,500 5,000 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Hour of Day 2019 2023 2028 2033 2038 Winter Jan, Dec Peak period definitions based on average daily load shape for each of the seasons: Summer peak Hour Ending (HE) 13-19 Winter Peak HE 7-10, HE 19-21 34

The Time-of-Use Pricing and Elasticity Assumptions Summer Winter High Reference High Reference Peak-to-OffPeak Ratio 3.5 3 2 1.5 TOU Off-peak discount 0.333 0.250 0.150 0.075 Flat base prices for each class/sector based on ELL Tariffs Residential - $0.04779/KWh Commercial - $0.03867/KWh Industrial - $0.00784/KWh These excluded the demand charges for commercial and industrial sectors 35

Other Program Assumptions All programs were assumed to be opt-in Adoption logic Initial adoption is limited by the AMI installations in the ELL service area Costs There are no incentive costs associated with the Time-of-Use programs 36

Additional Cost-effectiveness Results (PAC, RIM, and PCT Tests) 37

All cost-effective tests are calculated based on California Standard Practice Manual - Economic Analysis Of Demand-side Programs And Projects A copy of the manual can be found at http://www.cpuc.ca.gov/uploadedfiles/cpuc_public_website/content/utilities_and_industries/energy_- _Electricity_and_Natural_Gas/CPUC_STANDARD_PRACTICE_MANUAL.pdf The additional cost-effectiveness results include: Program Administrator Cost (PAC) Rate Impact Measure (RIM) Participant Cost Test (PCT)

Additional cost-effectiveness metrics for EE programs Program PAC RIM PCT Lighting, Appliances and Electronics 2.0 0.7 4.4 HVAC and Tune-up 7.5 0.8 3.8 Home Audit and Retrofit 3.7 0.8 2.9 Low Income Weatherization 1.9 0.5 2.8 Total Residential Programs Current 3.1 0.7 3.2 ENERGY STAR New Homes 9.2 0.8 3.7 Appliances Recycling 2.8 0.8 2.3 Home Energy Use Benchmarking 5.1 1.2 4.5 Grand Total Residential Programs Expanded + Current 4.2 0.8 3.1 39

Additional cost-effectiveness metrics for EE programs Program PAC RIM PCT Small Business Solutions 3.7 0.6 3.7 Current Commercial Prescriptive & Custom 3.5 0.6 6.7 Total Commercial Programs - Current 3.6 0.6 5.3 RetroCommissioning 6.8 0.6 6.0 Commercial New Construction 5.9 0.7 3.6 Commercial Prescriptive & Custom 2.9 0.6 6.8 Midstream Commercial Lighting 1.3 0.5 4.2 Grand Total Commercial Programs Expanded + Current 2.7 0.6 5.0 Industrial Prescriptive & Custom 3.1 0.6 14.8 Industrial Programs - Current 3.1 0.6 14.8 Industrial Strategic Energy Management 2.8 0.6 18.9 Grand Total Industrial Programs Expanded + Current 3.0 0.6 15.4 Portfolio Total - Current 3.3 0.7 5.0 Portfolio Total - Expanded 3.3 0.7 4.7 40

Additional cost-effectiveness metrics for DR programs Program Type Sector RIM Test PAC Test Reference Case High Case Reference Case High Case Residential DLC Residential 1.3 1.3 1.3 1.3 Residential ToU Residential 10.3 12.5 13.1 15.1 Residential Subtotal 2.0 2.3 2.0 2.3 Commercial DLC Commercial 1.0 1.1 1.0 1.1 Commercial ToU Commercial 4.4 5.6 5.6 7.1 Commercial Subtotal 1.4 1.6 1.5 1.7 Industrial ToU Industrial 12.6 13.2 13.1 13.8 Industrial Subtotal 12.6 13.2 13.1 13.8 All DLC 1.2 1.2 1.2 1.2 All ToU 9.9 11.5 11.7 13.2 Total DR Portfolio 2.4 2.6 2.4 2.7 Note: The PCT test is not applicable for these DR Programs since there is not cost to customers to participate in DR programs 41