INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER LABORATORY MIXING SKID

Similar documents
POWDER SYSTEMS LIMITED. simplefilter

Maintenance Instructions & Parts List

LSHT-120A Parker Pumps Parts & Service. PVP Series Variable Volume Piston Pump Service Bulletin. Model PVP16 **** 12. Hydraulics

1 year. The remainder of the original warranty period or 30 days from the date of replacement, whichever is longer. 3 years. 5 years.

LSHT-120A Parker Pumps Parts & Service. PHP Series Variable Volume Piston Pump Service Bulletin. Model PHP40 **** 10. Hydraulics

INSTALLATION & MAINTENANCE INSTRUCTIONS MODEL DDPV50 and DDPV54

Caution: This Unit is designed for atmospheric operation. DO NOT Pressurize Receiver. PLEASE LEAVE THIS MANUAL FOR OWNER S USE

IMPORTANT VERIFICATION OF WARRANTY REGISTRATION

ADDENDUM #1 RFQ M1201M. 06/07/13 Please replace Chiller Maintenance Specifications with the attached Chiller Maintenance Specifications.

Model QTS-5. QTS Industrial Series. Parts Manual

BIC MANUAL FILL. McDonald s USA Extended Warranty Program Blended Beverage Ice Machine

COLORADO DEPARTMENT OF LABOR AND EMPLOYMENT DIVISION OF OIL AND PUBLIC SAFETY BOILER AND PRESSURE VESSEL REGULATIONS

Dionex Electrolytic Water Purifier Installation Guide

Diesel Rx Diaphragm Fuel Pressure Regulator

INSTALLATION & MAINTENANCE INSTRUCTIONS MASTER-EX MODELS DDP14 - DDP50

OWNER S MANUAL. TRINITY 80 QT DETACHABLE STAINLESS STEEL COOLER W/ SHELF Model # TXK WARNING! Do not push cooler with cart on uneven surface.

INVITATION TO BID PURCHASING DEPARTMENT P.O. BOX NORTH ASHLEY ST. VALDOSTA, GEORGIA #LC Amy Woods, Finance Department

MSD Series Modular Membrane Air Dryers. Catalog 9CW-DX-233-1

ACTIVE EVACUATION SYSTEM (AES) OPERATIONS MANUAL

13. Manufacturer's warranty Marking 6 W A R N I N G!

Swing-Out Ball Valves (SWB Series) Catalog 4125-SWB Revised, April 2004

NITROGEN POWER RESERVE UNITS

iceless wine chil er

LSHT-120A Parker Pumps Parts & Service. PHP Series Variable Volume Piston Pump Service Bulletin. Model PHP1050 **** 10. Hydraulics

SVL. 250 For full technical and ordering information visit

Candock limited warranty

Thank you for the preference and we want to congratulate you for the excellent choice you

The Hotel Roanoke & Conference Center Invitation for Bid

EXTENDED WARRANTY PROGRAM GUIDE. Qualifying Qualifying is easy. To participate, you must be registered with Factory Assurance Southwest ( FAS ).

Personal Steam Sauna. Steam Sauna - SS03 (Pink or Blue) AC (Please refer to the rating label) 750W 60 Minutes Max 33 x 28.3 x 39.

The amendments to these regulations are created pursuant to , and (1)(a) of the Colorado Revised Statutes (CRS).

Rising Stem Plug Valves (PV Series) Catalog 4110-PV Revised, May 2004

Rule No. 16 Service Connections, Meters, and Customer s Facilities

Bulletin PM Service Parts Guide. Hydraulics. Model PAVC 100 **** 22. Effective: April, PAVC 100****22 Series Variable Volume Piston Pump

North Shore Gas Company. Billing and Price Book. Published September 2016

LIMITED LIFETIME TRANSFERABLE WARRANTY

OWNER S MANUAL. Fair Oaks 3pc Bar Set. Barstool

Parts List 852 Series

Sunstream FloatLift Powerpack Shelf kit Assembly and Installation Instructions

Manufactured in ISO9000:2000 Facility. Dimensions Conform to ASME B Threaded Items Conform to ASME B Manufactured from ASTM A105 Material

Vaporizing Regulators

Model QTS3QCB. Climate Control ol Series. Parts Manual Record of Change 3C. Manual No C3. February 2010 Edition

March Process Industry Practices Piping. PIP PNDMV09N Needle Valve Data Sheet and Standard Terms

Motor Wedges. Instruction Manual

Parts List 348 Series

EX BUCKET CYLINDER 2 Replace C/O RHS Bucket 11856hrs on changed out due to leaking.

Use and Care Guide Fair Oaks 3pc Bar Set Product Code D71 M80769 KSN 0 02640541 5 UPC Code 0 5087429162 2 Date of Purchase

Parts List 247 Series

Parts List 800 Series

THIS WARRANTY APPLIES ONLY TO 2015 AND LATER YEAR MODELS OF NEW K-TEC SCRAPERS ( K-TEC SCRAPER ).

Shower Column SHCM Installation Guide

BUTLER SYSTEM WARRANTY BOOKLET

Cinelabs Sanyo EZ-20 Flyback Installation Guide

INSTALLATION AND OPERATING MANUAL

Catalog of Cleaned for Oxygen Copper Fittings

SOLARUS, INC. 15 YEAR LIMITED WARRANTY SOLAR THERMAL EVACUATED TUBE COLLECTOR DATED AS OF JANUARY 1, 2011

ASTRO 2 CIRCULATORS. ASTRO 2 3-Speed Circulators (except Astro 286):

MTBlandcorp Malemilkingmachine Ultimately Woman Tampa, Florida USA Telephone:

Parts List 867 Series

Cylinder Connections. CGA DISS Series

Property Inspection Guidelines

3M Super Close Projection System SCP712

INSTALLATION GUIDE. Kitchen Strainer ST-1 / ST-3 / BST-1

TWBS1-WIS UNIT WEIGHT: 28 LB WEIGHT CAPACITY PER SHELF/TIER: 15 LB. Sacramento Bookcase

MODULATING VALVE KIT INSTALLATION MANUAL. P/N Rev 0

REFRESHMENT CENTER / INSULATED SINK Installation Instructions GRC / GRCHS / GIS / GISHS / AGIB

Use and Care Guide Moore Haven Woven Club Chair Neutral Color Product Code D71 M20333 KSN 0 08752124 1 UPC Code 0 5087452510 9 Date of Purchase

Parts List 245 Series

950 Series. Exploded Views. Buckner Superior / 950 Series / Exploded Views. Phone: Toll: Fax:

R-407C REFRIGERANT LORC, LNH, LNL, LNQ AND LNX SERIES OUTDOOR AIR-COOLED REMOTE CONDENSERS STANDARD FEATURES VERTICAL DISCHARGE

Introduction. Installation. Unpacking and Inspection. Installation Preparation. Installation Procedure

Town of Holly Springs

VALVES Product Specifications

Bankable Control Valves BV06 BVB06 BVCS10 BV10 BV18

BEETLE CURVED PIPE & TUBE CLEANING NOZZLES USER MANUAL

OWNER S MANUAL INFLATABLE HIGH JUMP LANDING SYSTEMS. Exclusively Distributed by: Blazer Athletic

Use and Care Guide Fair Oaks Cushioned Chaise Product Code D71 M80777 KSN 0 02640592 8 UPC Code 0 5087429167 7 Date of Purchase

Breathing air. The breath of performance

WARRANTY INFORMATION

Extremely hot - Severe burnes can occur on contact. Hazardous fl uids can Hazardous. could cause personal injury or property damage.

HARTSELLE UTILITIES INVITATION FOR BID

DENISON PRICE LISTING

THE NEW ANGLE GRINDERS WWB 200 PLUS / WWB 300 PLUS THE FIRST TO INCREASE OUTPUT ON THEIR OWN AND LOWER OPERATING COSTS. laska.at

SUPER WEDGE DRIVES 3V, 5V, AND 8V CROSS SECTIONS SPECIAL MADE-TO-ORDER SHEAVES USE WITH FUL-GRIP (QD) BUSHINGS

VL1250 CANOPY INSTRUCTIONS

Parts List 870/877 Series

COUNTOUR CANOPY ASSEMBLY, INSTALLATION & USE MANUAL READ CAREFULLY KEEP THESE INSTRUCTIONS MODEL NUMBERS 24108

Easystream kW PACKAGED SCROLL CHILLERS

INSTALLATION GUIDE OWNER S MANUAL

The amendments to this rule are created pursuant to , and (1)(a) of the Colorado Revised Statutes (CRS).

Double Riser Swage INSTALLATION MANUAL

EXPLOSION PROOF VACUUM DS2-EX

YAMAHA MOTOR CORPORATION, U.S.A. YAMALUBE ENGINE LUBRICATION LIMITED WARRANTY

Ford Power Stroke 7.3L Edge Products EZ Module Installation Instructions & Manual OLD P/N: EZF1000 NEW P/N: 10200

Rolling Knee Dolly. Owner s Manual

STAINLESS STEEL CAST FITTINGS 150lb 304 & 316 Stainless Steel Cast Fitting List Prices (SSC-0317)

2-Bike Hitch Platform

Consumer Mowing Equipment Limited Warranty

Policy and Procedure Manual Table of Contents

Daniel Aviation Refueler Surge Pilot Valves

Transcription:

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER LABORATORY MIXING SKID MODEL MSTCCA DRAWING NUMBER AD406CC MANUAL NUMBER IOM-136 REVISION Rev. B, 12/22/2016

TABLE OF CONTENTS SAFETY 3 1. PRODUCT INFORMATION 4 1.1 Introduction 4 1.2 Product Description 4 1.3 Specifications 5 1.4 Equipment Diagrams 6 2. INSTALLATION & OPERATION 8 2.1 Before You Begin 8 2.2 Installing the MSTCCA 8 2.3 Installing the TCC to the MSTCCA 9 2.4 Operation 10 3. MAINTENANCE 11 3.1 Before You Begin 11 3.2 Maintenance 12 3.3 Cleaning the TCC Using the MSTCCA 12 APPENDIX 14 A: Referenced or Attached Documents 14 Welker, W Welker, W logo, WelkerScope, Welker Jet, and OdorEyes are Registered Trademarks owned by Welker, Inc. 2 IOM-136 MODEL: MSTCCA REV: B 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

SAFETY IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS Notes emphasize information and/or provide additional information to assist the user. Caution messages appear before procedures that could result in damage to equipment if not observed. Warning messages appear before procedures that could result in personal injury if not observed. This manual is intended to be used as a basic installation and operation guide for the Welker Laboratory Mixing Skid, MSTCCA. For comprehensive instructions, please refer to the IOM Manuals for each individual component. A list of relevant component IOM Manuals is provided in Appendix A of this manual. The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for the installation, operation, and maintenance of the Welker equipment described in this manual. Correct installation and operation, however, are the responsibility of the end user. Welker reserves the right to make changes to this manual and all products in order to improve performance and reliability. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT - Save these instructions for local inspector's use. IMPORTANT - Observe all governing codes and ordinances. Note to Installer - Leave these instructions with the end user. Note to End User - Keep these instructions for future reference. Installation of this Laboratory Mixing Skid is of a mechanical nature. Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the warranty. If you received a damaged Laboratory Mixing Skid, please contact a Welker representative immediately. Phone: 281.491.2331 Address: 13839 West Bellfort Street Sugar Land, TX 77498 3 IOM-136 MODEL: MSTCCA REV: B 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

SECTION 1: PRODUCT INFORMATION 1.1 Introduction We appreciate your business and your choice of Welker products. The installation, operation, and maintenance liability for this equipment becomes that of the purchaser at the time of receipt. Reading the applicable Installation, Operation, and Maintenance (IOM) Manuals prior to installation and operation of this equipment is required for a full understanding of its application and performance prior to use.* If you have any questions, please call Welker at 1-281-491-2331. *The following procedures have been written for use with standard Welker parts and equipment. Assemblies that have been modified may have additional requirements and specifications that are not listed in this manual. 1.2 Product Description The Welker MSTCCA Laboratory Mixing Skid is designed specifically for use with Welker TCC Transportable Crude Oil Containers to provide a quality sample for basic sediment and water (BS&W) monitoring. Over time, sample collected in a TCC may stratify. The MSTCCA will mix the contents of the connected TCC to achieve a homogenous and representative sample. In addition, the MSTCCA is capable of cleaning the TCC after use. Welker may custom design the MSTCCA to suit the particular application and specifications of each customer. 4 IOM-136 MODEL: MSTCCA REV: B 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

1.3 Specifications The specifications listed in this section are generalized for this equipment. Welker can modify the equipment according to your company's needs. Please note that the specifications may vary depending on the customizations of your equipment. Applications Materials of Construction Maximum Allowable Operating Pressure Connections Utility Requirement Dimensions Features Industry Standards Table 1: MSTCCA Specifications Mixing Contents of Welker TCC Cleaning Welker TCC Carbon Steel Skid With Carbon Steel Fittings 100 psig @ -4 F to 100 F (6 barg @ -20 C to 37 C) Discharge: ½" Quick-Connect Drain: ½" FNPT Pneumatic Supply to Motor: ½" FNPT Spot Sample Draw Off: ¼" FNPT Suction: ½" Quick-Connect Regulated Pneumatic Supply 24" x 28" (Length x Width) Air Lubricator/Oiler Air Motor Flexible Hoses With Quick-Connects Placement Ring for Welker TCC Transportable Crude Oil Container Pump With Internal Relief Sample Draw Off Valve Static Mixer API Chapter 8 ASTM D4177 ISO 3171 5 IOM-136 MODEL: MSTCCA REV: B 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

1.4 Equipment Diagrams Figure 1: MSTCCA Connections Diagram 6 IOM-136 MODEL: MSTCCA REV: B 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

Figure 2: MSTCCA Diagram 7 IOM-136 MODEL: MSTCCA REV: B 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

SECTION 2: INSTALLATION & OPERATION 2.1 Before You Begin After unpacking the unit, check the equipment for compliance and any damage that may have occurred during shipment. Immediately contact a Welker representative if you received damaged equipment. When sealing fittings with PTFE tape, refer to the proper sealing instructions for the brand used. The Welker MSTCCA will ship skid-mounted and "hard-tube" connected with manufacturer-supplied fittings and hardware. However, the customer will need to supply some tubing and fittings in order to complete the installation of the system. These instructions are written with the assumption that the Welker MSTCCA is being used to mix the contents of a Welker TCC Transportable Crude Oil Container. While it is possible to use the MSTCCA and the TCC with equivalent third-party equipment, the MSTCCA has been designed to take full advantage of the features of the TCC to provide a quality sample for basic sediment and water (BS&W) monitoring. 2.2 Installing the MSTCCA 1. Install the MSTCCA to the desired location as close as possible to the regulated pneumatic supply source. 2. Mount the MSTCCA to the desired location in accordance with the bolting pattern (Figure 3). Figure 3: Bolting Pattern 3. Connect a grounding wire to the MSTCCA to safely ground the skid. 4. Using ½" tubing, connect from the customer pneumatic supply with on/off valve to air supply inlet valve B (Figure 1). 5. Using tubing or pipe, connect from drain valve D to an appropriate draining location or sump (Figure 1). 8 IOM-136 MODEL: MSTCCA REV: B 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

6. As necessary, fill the reservoir of the air lubricator/oiler to the maximum fill line with oil compatible with the seal material (Figure 2). Refer to the Installation, Operation, and Maintenance (IOM) Manual for the air lubricator/oiler for instructions on filling the reservoir and for recommendations on the type of oil to use. 7. Regulate the pneumatic supply to no more than 100 psig (6 barg). Refer to the Installation, Operation, and Maintenance (IOM) Manual for the air motor for information on the relationship between pneumatic supply pressure, motor speed, torque, and horsepower. 2.3 Installing the TCC to the MSTCCA A pressure relief valve is required on the sample container. Welker recommends grounding all containers to prevent static shock. 1. Ensure that the lid of the TCC is properly closed. Refer to the Installation, Operation, and Maintenance (IOM) Manual for the TCC for instructions on properly closing the lid of the TCC. If the lid of the TCC is not properly closed before operation, the sample may be compromised. An improperly closed lid may allow water to enter or vapors to escape the sample. 2. Place the TCC on the skid. 3. Position the TCC within the placement ring so that the sample outlet and sample return quick-connects on the TCC point toward the suction and discharge quick-connects on the MSTCCA. 4. Using one (1) of the provided flexible hoses with quick-connects, connect from the suction quick-connect on the MSTCCA to the sample outlet on the bottom of the TCC (Figure 1 and Figure 2). The quick-connects will audibly click into place. 5. Using the other provided flexible hose with quick-connects, connect from the discharge quick-connect on the MSTCCA to the sample return on the top of the TCC (Figure 1 and Figure 2). The quick-connects will audibly click into place. 9 IOM-136 MODEL: MSTCCA REV: B 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

2.4 Operation DO NOT operate the MSTCCA unless the flexible hoses with quick-connects are connected to the TCC and the TCC is filled with sample or cleaning solvent. Operating the MSTCCA when the TCC is not properly installed or when the TCC is empty could damage the pump and motor. 1. Ensure that all valves are closed. 2. Ensure that the MSTCCA is connected to the pneumatic supply. 3. Ensure that drain valve D is connected to an appropriate draining location or sump (Figure 1). 4. Ensure that the TCC is properly connected to the MSTCCA. 5. Ensure that the lid of the TCC is properly closed. Refer to the Installation, Operation, and Maintenance (IOM) Manual for the TCC for instructions on properly closing the lid of the TCC. If the lid of the TCC is not properly closed before operation, the sample may be compromised. An improperly closed lid may allow water to enter or vapors to escape the sample. 6. Open air supply inlet valve B, and then open the on/off valve on the customer pneumatic supply (Figure 2). 7. As necessary, refer to the Installation, Operation, and Maintenance (IOM) Manual for the air motor for information on the relationship between pneumatic supply pressure, motor speed, torque, and horsepower. 8. Allow the contents of the TCC to mix in accordance with company policy. Take care not to overmix the sample, as overmixing can push out the light ends, create an emulsion, and heat the sample. Taking a Spot Sample Welker recommends grounding all containers to prevent static shock. 9. Open sample draw off valve A (Figure 2). 10. Hold an atmospheric container under the spot sample draw off to collect sample as it purges (Figure 1). 11. Once the spot sample draw off has been purged, replace the atmospheric container being held under the spot sample draw off with a graduated beaker. 12. Allow the graduated beaker to fill to the desired volume, and then close sample draw off valve A (Figure 2). Consult company policy for the volume of sample required for testing. 13. After extracting the required amount of sample, proceed to Section 3.3, Cleaning the TCC Using the MSTCCA, to clean the MSTCCA and TCC while the MSTCCA is still operating. 10 IOM-136 MODEL: MSTCCA REV: B 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

SECTION 3: MAINTENANCE 3.1 Before You Begin 1. Welker recommends that the MSTCCA and the TCC be cleaned after each use. If the TCC is stored for some time prior to use, the TCC may need to be cleaned prior to use. 2. Welker recommends that the unit have standard yearly maintenance under normal operating conditions. In cases of severe service, dirty conditions, excessive usage, or other unique applications that may lead to excess wear on the unit, a more frequent maintenance schedule may be appropriate. 3. Prior to maintenance or disassembly of the unit, it is advisable to have a repair kit available for repairs of the system in case of unexpected wear or faulty seals. New seals supplied in spare parts kits should be lightly lubricated before being installed to ease the installation of the seals and reduce the risk of damage when positioning them on parts. Wipe excess lubricant from the seals, as it may adversely affect analytical instrument results. For sample-exposed seals, Welker recommends non-hydrocarbon-based lubricants, such as Krytox. For non-sample-exposed seals, Welker recommends either non-hydrocarbon-based lubricants or silicone-based lubricants, such as Molykote 111. After the seals are installed, the outer diameter of shafts and inner diameter of cylinders may be lubricated to allow smooth transition of parts. 4. All maintenance and cleaning of the unit should be performed on a smooth, clean surface. 5. Welker recommends having the following tools available for maintenance. Please note that the exact tools required may vary by model. a. Adjustable Wrench b. Hex Key Set c. Seal Pick d. Tubing Cutters 11 IOM-136 MODEL: MSTCCA REV: B 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

3.2 Maintenance 1. During operation, monitor the MSTCCA for leaks. If leaks are present, halt operation and repair as necessary. 2. Occasionally, a system component may need to be repaired or removed for manufacturer's recommended maintenance. To perform maintenance on components: a. Depressurize the MSTCCA and close all valves. b. Turn OFF all pneumatics to the MSTCCA. c. Drain the contents of the MSTCCA to a safe recovery system or sump. d. Disconnect the tubing and piping and remove individual components for maintenance. e. For complete and proper maintenance on individual components, refer to their respective Installation, Operation, and Maintenance (IOM) Manual. A list of component Installation, Operation, and Maintenance (IOM) Manuals is available in Appendix A, Referenced or Attached Documents, in this manual. f. After performing necessary maintenance on component parts, reconnect all instrument tubing and piping. g. Install the MSTCCA according to the instructions in Section 2.2, Installing the MSTCCA. 3. Clean the TCC and MSTCCA. See Section 3.3, Cleaning the TCC Using the MSTCCA, for instructions. 3.3 Cleaning the TCC Using the MSTCCA DO NOT operate the MSTCCA unless the flexible hoses with quick-connects are connected to the TCC and the TCC is filled with sample or cleaning solvent. Operating the MSTCCA when the TCC is not properly installed or when the TCC is empty could damage the pump and motor. Cleaning the TCC 1. With the TCC installed to the MSTCCA and the MSTCCA still operating, open drain valve D (Figure 2). Allow the contents of the TCC and MSTCCA to pump through the system to the sump. 2. Once draining is complete, close drain valve D (Figure 2). 3. Close the on/off valve on the customer pneumatic supply, and then close air supply inlet valve B (Figure 2). 4. Open sample draw off valve A to depressurize the TCC, and then close valve A (Figure 2). The TCC must be depressurized before opening the lid of the TCC. Removing the lid of the TCC under pressure could cause severe injury. 5. Open the lid of the TCC. 6. Fill the TCC half full with cleaning solvent. Welker recommends cleaning the TCC with a quick-evaporating solvent, such as acetone. Refer to the appropriate company policy for the approved quick-evaporating solvent. Use chemical solvents safely, following all personal protective equipment (PPE) and usage directions listed on the solvent label and Material Safety Data Sheet (MSDS). 7. Close the lid of the TCC. Refer to the Installation, Operation, and Maintenance (IOM) Manual for the TCC for instructions on properly closing the lid of the TCC. 8. Open air supply inlet valve B, and then open the on/off valve on the customer pneumatic supply (Figure 2). 9. Allow the cleaning solvent to circulate through the system for approximately two (2) minutes or until any sample remaining in the system is diluted. 12 IOM-136 MODEL: MSTCCA REV: B 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

10. Open drain valve D and allow the contents of the TCC and MSTCCA to pump through the system to the sump (Figure 2). 11. Once draining is complete, close drain valve D (Figure 2). 12. Close the on/off valve on the customer pneumatic supply, and then close air supply inlet valve B (Figure 2). 13. Repeat steps 4 12 until the cleaning solvent runs clear when drained. Disconnecting the TCC From the MSTCCA 14. Ensure that the on/off valve on the customer pneumatic supply and air supply inlet valve B are closed (Figure 2). 15. Disconnect the discharge flexible hose with quick-connects from the sample return on the TCC (Figure 2). The discharge flexible hose with quick-connects may remain connected to the MSTCCA. 16. Disconnect the suction flexible hose with quick-connects from the sample outlet on the TCC (Figure 2). The suction flexible hose with quick-connects may remain connected to the MSTCCA. 17. Manually remove the TCC from the skid. Drying the TCC 18. Depressurize the TCC. The TCC must be depressurized before opening the lid of the TCC. Removing the lid of the TCC under pressure could cause severe injury. 19. Open the lid of the TCC. 20. Carefully dry the inside of the TCC with a clean, dry cloth. 21. Close the lid of the TCC. Refer to the Installation, Operation, and Maintenance (IOM) Manual for the TCC for instructions on properly closing the lid of the TCC. 22. The cleaned TCC may be installed to a sampling system. If the TCC will be stored prior to use, tape, cap, or plug the ports on the TCC to prevent moisture and/or insects from entering. 13 IOM-136 MODEL: MSTCCA REV: B 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

APPENDIX A: REFERENCED OR ATTACHED DOCUMENTS Welker Installation, Operation, and Maintenance (IOM) Manuals suggested for use with this unit: IOM-035: Welker SP-1, SP-1W, SP-2, SP-3, and SP-5 Sample Probes IOM-117: Welker TCC-1 Transportable Crude Oil Container IOM-197: Welker TCC-5 Transportable Crude Oil Container IOM-206: Welker TCC-2 Transportable Crude Oil Container IOM-207: Welker TCC-3 Transportable Crude Oil Container IOM-208: Welker TCC-10 Transportable Crude Oil Container Other Installation, Operation, and Maintenance (IOM) Manuals suggested for use with this unit: Apollo Valves 73A-100 Series Carbon Steel Ball Valve (Welker IOM-V151) BSM Pump Corporation S-Series Rotary Gear Pumps (Welker IOM-V323) Globe Airmotors B.V. Pneumatic Vane Motors (Welker IOM-V326) Norgren L74M and L74C Micro-Fog and Oil-Fog Tool Lubricators (Welker IOM-V325) Parker Hannifin Corporation Ball and Plug Valves (Welker IOM-V213) Parker Hannifin Corporation Hose, Fittings and Equipment (Welker IOM-V162) Parker Hannifin Corporation Instrumentation Quick Coupling Products (Welker IOM-V293) Welker drawings and schematics suggested for use with this unit: Assembly Drawing: AD406CC 14 IOM-136 MODEL: MSTCCA REV: B 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

NOTES 13839 West Bellfort Street Sugar Land, TX 77498 Phone: 281.491.2331 welker.com 15 IOM-136 MODEL: MSTCCA REV: B 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331