Siemens Combustion Control Modbus Solution: LMV51

Similar documents
Square D Modbus Solution: Altivar 58 VFD

McQuay BACnet Solution: Microtech II Applied Rooftop Unit Controller with Discharge Air Control (DAC)

APOGEE Open Processor with Cummins/Onan Modbus Driver: PowerCommand System

LONWORKS Solution to Danfoss Graham VLT 6000 Adjustable Frequency Drive

PROGRAMMING GUIDE FOR PPC6000 SERIES

SHORT-TERM OPERATING RESERVE DESPATCH PROCEDURE STOR DESPATCH PROCEDURE. for Non-Balancing Mechanism Participants

WHITE PLAINS MECHANICAL CODE PART 1. GENERAL REQUIREMENTS

IEC : Annex F

Generation Production Costs, Scheduling & Operating Rate

Using Date and Date/Time in Formulas

EXAMPLE OF SBIS TENURE CALCULATION. Example of the calculation of SBIS with 3 (three) month-tenure based on the. Date of auction : August 11, 2010

Design of SIFs and SIL Calculation What to expect from the Course? Understand Learn Benefit Methodology (online course)

Direct Install (DI) Program. Program Guide. Fiscal Year 2019 (7/1/2018 through 6/30/2019)

Baltimore Gas and Electric Company -- Gas GAS SERVICE TARIFF. 1. General 2. Terms and Conditions 3. Rates PART 1. GENERAL. 1. Filing And Posting

Chapter 13 Payroll Accounting, Taxes, and Reports

HAZOP AND SAFETY INTEGRITY OVERVIEW

June 15, City Of Rochelle 420 N 6th St Rochelle, IL Att: Ms. Sue Messer. UPDATED: Old Building / HVAC Controls and Energy Improvements

MONTHLY REPORT September 20 18

LGS-RTP-19 Sheet 1 of 5

13 NCAC is amended with changes as published in 31:09 NCR as follows:

COMPLIANCE & ENFORCEMENT DIVISION

COLORADO DEPARTMENT OF LABOR AND EMPLOYMENT DIVISION OF OIL AND PUBLIC SAFETY BOILER AND PRESSURE VESSEL REGULATIONS

Pump Controllers Industrial / Commercial / Municipal

Labor Chapter ALABAMA DEPARTMENT OF LABOR ADMINISTRATIVE CODE CHAPTER GENERAL PROVISIONS TABLE OF CONTENTS

The amendments to these regulations are created pursuant to , and (1)(a) of the Colorado Revised Statutes (CRS).

Yakima County Code ~ Building and Construction ~ Title FEES

2014 No ENERGY. The Domestic Renewable Heat Incentive Scheme Regulations 2014

Understanding the customer s requirements for a software system. Requirements Analysis

Affinity Group 1 January 15, 2019

NATIONAL SENIOR CERTIFICATE GRADE 12

User Manual for Filing the Monthly Contribution and Payment of dues

ACCD Exhibitor Services - Palmer Information Packet

Regulatory Reform (Fire Safety) Order 2005: An Insurer s View. Mark Newton Property Technical Manager Royal & Sunalliance Insurance

No-Load Definition: Educational Document

Pay in Advance Energy A Discounted Deal

Legend expert advisor

- Page 1 of 5- PRODUCER PROFILE PLEASE PRINT OR TYPE

Customer account name Phone ( Installation address City State Mailing address City State

Direct Install (DI) Program. Program Guide. Fiscal Year 2018 (7/1/2017 through 6/30/2018)

Unit Ventilator Ceiling Water Source Heat Pump

.! 4 5 2!, S E R V I C E P L A N S!)2

INVITATION TO BID. Condensing Boilers For Chippewa Valley Technical College 620 West Clairemont Avenue Eau Claire WI

Reducing Project Lifecycle Cost with exsilentia

Practical SIS Design and SIL Verification

WISCONSIN GAS LLC Gas Service Rates, Rules and Regulations. Tariff Book

Optimizing the service of the Orange Line

BUILDING SUBCODE FEES:

NC Independent Living Attendant Sample Forms Packet

CITY OF LOS BANOS PUBLIC WORKS DEPARTMENT INVITATION FOR SEALED BIDS PROPOSAL FOR THE PURCHASE OF ONE NEW 2018/2019 MODEL BRUSH CHIPPER

CAMPTON HILLS POLICE DEPARTMENT 40W270 LAFOX RD. CAMPTON HILLS, IL 60175

The Domestic Renewable Heat Incentive Scheme Regulations (Northern Ireland) 2014

Richmond Building Energy Challenge

TRID FAQs: Payment Columns and the Black Hole

ANNUAL LEAVE, PUBLIC HOLIDAYS AND DISCRETIONARY DAYS GUIDANCE

Annual Report. Aktiebolaget SKF, SE- Göteborg, Sweden Telephone + - -, fax + - -

HOSPITALITY APPLICATION

Delayed Coker Engineering Experience Horizon Oil Sands Project. September 9, 2008

Your Company Header. IEC :2016 Annex F SAFETY INTEGRITY LEVEL VERIFICATION. Example Project

MiCOM P443-6/P543-7/P841

Invitation to Bid. Attached you will find a Bid Form. If you have any questions, feel free to call or me directly.

Thuraya Satellite PCO

SPP Reserve Sharing Group Operating Process

D-Series Syringe Pumps: a systems building guide

RULES / REGULATIONS / GENERAL INFORMATION

Boiler Operation Engineer s Examination-2016 BOE-2016 Last Date: NOTIFICATION

IBPS PO PRE (quantitative aptitude) Memory Based paper held on 7_Oct_2017

The amendments to this rule are created pursuant to , and (1)(a) of the Colorado Revised Statutes (CRS).

AccèsD Affaires: your door to a world of possibilities

Welcome to Midland States Bank

Standard Motor Products, Inc.

CAISO MAP Market Simulation Conference Call. February 22, 2011

This branch is closing but your bank is always open

TOWNSHIP OF FRANKLIN O-6-18 ORDINANCE AMENDING CHAPTER OF THE CODE OF THE TOWNSHIP OF FRANKLIN- CONSTRUCTION PERMITS

WISCONSIN ELECTRIC - GAS OPERATIONS Gas Service Rates, Rules and Regulations. Tariff Book

Budget Module Overheads

BOILER LAW Health and Safety Code, Chapter 755 Administered by the Texas Department of Licensing and Regulation (Effective September 1, 2009)

Setting Financial Goals

INDIAN HILLS UTILITY OPERATING COMPANY, INC. CUSTOMER RIGHTS AND RESPONSIBILITIES

AMADOR WATER AGENCY SCHEDULE OF MISCELLANEOUS FEES AND CHARGES

You can use date and time values to stamp documents and to perform date and time

RRC STAFF OPINION PLEASE NOTE: THIS COMMUNICATION IS EITHER 1) ONLY THE RECOMMENDATION OF AN RRC

heating, ventilation and cooling systems incentive application for businesses

1. The fee for plan review shall be due upon completion of subcode review.

Analysing cost and revenues

dc water guide to customer services district of columbia water and sewer authority

Gaz Métro Limited Partnership Conditions of Natural Gas Service

2016 Statewide Retrocommissioning Policy & Procedures Manual

Air Conditioner, Heat Pump, ECU, PTAC, GPac Warranty Statement and Policies

Boilers & Unfired Pressure Vessels

Critical Dates and Important Deadlines

THEREFORE, the [enter appropriate legislative body] for County, Maryland approves the following Act:

Standard Motor Products, Inc.

Director Risk & Reliability, HSB Professional Loss Control

The following additional terms and conditions apply to the provision of the Landline Service.

Toronto Public Library

Draft Measure Information Template Cooling Tower Efficiency and Turndown

1 Exam Prep Florida Contractor s Reference Manual Practice Test 3

REVISED SCOPE OF WORK

BOILER AND UNFIRED PRESSURE VESSEL LAW Act of Jun. 18, 1998, P.L. 655, No. 85 AN ACT Regulating the construction, equipment, maintenance, operation

SCHEDULE 23 IRRIGATION PEAK REWARDS PROGRAM (OPTIONAL)

Transcription:

Point Map March 11, 2005 Systems Integration Siemens Combustion Control Modbus Solution: LMV51 ForHotWaterBoilers Table 1. LMV51 Burner Controller for Hot Water Boilers Point Map, Application 4642. 1 LAO Address 2 LAI Application 3 LDI Communication Error Off/On 4 LAO IP Address 1 5 LAO IP Address 2 6 LAO IP Address 3 7 LAO IP Address 4 8 LAO IP Port 9 LAO Base Offset 10 LAO Send Initial Value 11 LAI Phase See LMV51 and LMV52 Basic 12 LAI Position of Currently Active Fuel Actuator 13 LAI Position of Gas Actuator 14 LAI Position of Oil Actuator 15 LAI Position of Air Actuator 16 LAI Position of Auxiliary Actuator 1 17 LAI Position of Auxiliary Actuator 2 18 LAI Position of Auxiliary Actuator 3 19 LAI Manipulated Variable for Variable Speed Drive % 20 LAI Current Type Fuel 0=Gas 21 LAI Current Output (Fire Rate) % 22 LAI Current Hot Water Setpoint F 23 LAI Hot Water Temperature F Siemens Building Technologies, Inc. Page 1 of 10

Table 1. LMV51 Burner Controller for Hot Water Boilers Point Map, Application 4642. (continued) 24 LAI Flame Signal % 25 LAI Current Fuel Throughput 26 LAI Volume Unit of Gas 0=Cubic Meters 1=Cubic Feet 27 LAI Volume Unit of Oil 0=Liters 1=Gallons 28 LAI Unit of Temperature 0=Deg C 1=Deg F 29 LAI Unit of Pressure 0=bar 1=psi 30 LAI Sensor Selection 0=Pt100 1=Pt1000 2=Ni1000 3=Temperature Sensor 4=Pressure Sensor 5=Pt100Pt1000 6=Pt100Ni1000 7=No Sensor 31 LAI Startup Counter Total 32 LAI Hours Run Counter 33 LAI Current Error: Error Code 34 LAI Current Error: Diagnostic Code 35 LAI Current Error: Error Class 36 LAI Current Error: Error Phase See LMV51 and LMV52 Basic 37 LAI Temperature Limiter Off Threshold F 38 LAI Supply Air Temperature F 39 LDI Controller On/Off Off/On 40 LDI Fan Contactor Contact Off/On 41 LDI Fuel Selection Oil Off/On 42 LDI Fuel Selection Gas Off/On 44 LDI Maximum Oil Pressure Switch Off/On 45 LDI Minimum Oil Pressure Switch Off/On 46 LDI Pressure Valve Proving Off/On 47 LDI Safety Chain Off/On 49 LDI Maximum Gas Pressure Switch Off/On 50 LDI Minimum Gas Pressure Switch Off/On 52 LDI LP Off/On Page 2 of 10 Siemens Building Technologies, Inc.

Table 1. LMV51 Burner Controller for Hot Water Boilers Point Map, Application 4642. (continued) 53 LDI Start Release Oil Off/On 54 LDI Heavy Oil Immediate Start Off/On 55 LDI Alarm Off/On 59 LDI Ignition Off/On 60 LDI Start Signal/DW Valve Off/On 61 LDI Fan Off/On 62 LDI Oil Pump/Magnetic Coupling Off/On 63 LDI Fuel Valve SV Oil Off/On 64 LDI FuelValveV1Oil Off/On 65 LDI FuelValveV2Oil Off/On 66 LDI Fuel Valve V3 Oil Off/On 67 LDI Fuel Valve SV Gas Off/On 68 LDI FuelValveV1Gas Off/On 69 LDI FuelValveV2Gas Off/On 70 LDI Fuel Valve PV Gas Off/On 71 LAO Operating Mode with Load Controller 0=ExtLR X5-03 1=IntLR 2=IntL Bus 3=IntLR X62 4=ExtLR X62 5=ExtLR Bus 72 LAI Selection of Manual or Automatic Operation 0=Automatic 1=Burner On 2=Burner Off 73 LDO Modbus Mode Local/Remote 74 LAO Modbus Downtime: Maximum Time with No Communication. When This Time Has Elapsed, Automatic Changeover from Remote to Local Takes Place. 75 LAO Operating Mode in Remote Mode 0=Auto 1=Remote On 2=Remote Off 76 LAO External Setpoint W3 F 77 LAO Predefined Output Modulation/Multistage 0 to 100.0%=Full Modulation 100.1%=Stage1 100.2%=Stage2 100.3%=Stage3 78 LAO Fuel Selection 0=Gas 79 LAO Setpoint W1 F sec Siemens Building Technologies, Inc. Page 3 of 10

Table 1. LMV51 Burner Controller for Hot Water Boilers Point Map, Application 4642. (continued) 80 LAO Setpoint W2 F 81 LAO Weekday 0=Sunday 1=Monday 2=Tuesday 3=Wednesday 4=Thursday 5=Friday 6=Saturday 82 LAO Year yyyy 83 LAO Month mm 84 LAO Day dd 85 LAO Hour hr 86 LAO Minute min 87 LAO Second sec 89 LAO Hours Run Gas (Can Be Reset by Setting This 90 LAO Hours Run Oil Stage 1 or Modulating (Can Be Reset by Setting This 91 LAO Hours Run Oil Stage 2 or Modulating (Can Be Reset by Setting This 92 LAO Hours Run Oil Stage 3 or Modulating (Can Be Reset by Setting This 93 LAO Hours Run Total (Can Be Reset by Setting This 94 LAI Hours Run Total 96 LAI Hours Run Device Connected to Power (Read Only) 97 LAO Startup Counter Gas (Can Be Reset by Setting This 98 LAO Startup Counter Oil (Can Be Reset by Setting This 99 LAO Startup Counter Total (Can Be Reset by Setting This 100 LAI Startup Counter Total 101 LAI Fuel Volume Gas cu ft m 3 102 LAI Fuel Volume Oil gal L 103 LAI Number of Lockouts 104 LAI Lockout History (Current Lockout) Error Code 105 LAI Lockout History (Current Lockout) Error Diagnostics 106 LAI Lockout History (Current Lockout) Error Class 107 LAI Lockout History (Current Lockout) Error Phase See LMV51 and LMV52 Basic Page 4 of 10 Siemens Building Technologies, Inc.

Table 1. LMV51 Burner Controller for Hot Water Boilers Point Map, Application 4642. (continued) 108 LAI Lockout History (Current Lockout) Fuel 0=Gas 109 LAI Lockout History (Current Lockout) Output % 110 LAI Lockout History (Current Lockout) Date: Year yyyy 111 LAI Lockout History (Current Lockout) Date: Month mm 112 LAI Lockout History (Current Lockout) Date: Day dd 113 LAI Lockout History (Current Lockout) Time of Day: Hours hr 114 LAI Lockout History (Current Lockout) Time of Day: Minutes 115 LAI Lockout History (Current Lockout) Time of Day: Seconds 116 LAI Lockout History (Current Lockout) Startup Counter Total 117 LAI Lockout History (Current Lockout) Hours Run Total 118 LAI Error History (Current Error) Error Code 119 LAI Error History (Current Error) Error Diagnosis 120 LAI Error History (Current Error) Error Class 121 LAI Error History (Current Error) Error Phase See LMV51 and LMV52 Basic 122 LAI Error History (Current Error) Error Fuel 123 LAI Error History (Current Error) Error Output 124 LAI Error History (Current Error) Error Startup Counter Total a Values noted for LDIs and LDOs are in the following format: OFF text/on text. b This column indicates the value/range or engineering units or both if known. c The default English value is not italicized. An italicized entry indicates an SI value. Siemens Building Technologies, Inc. Page 5 of 10

For Steam Boilers Table 2. LMV51 Burner Controller for Steam Boilers Point Map, Application 4643. 1 LAO Address 2 LAI Application 3 LDI Communication Error Off/On 4 LAO IP Address 1 5 LAO IP Address 2 6 LAO IP Address 3 7 LAO IP Address 4 8 LAO IP Port 9 LAO Base Offset 10 LAO Send Initial Value 11 LAI Phase See LMV51 and LMV52 Basic 12 LAI Position of Currently Active Fuel Actuator 13 LAI Position of Gas Actuator 14 LAI Position of Oil Actuator 15 LAI Position of Air Actuator 16 LAI Position of Auxiliary Actuator 1 17 LAI Position of Auxiliary Actuator 2 18 LAI Position of Auxiliary Actuator 3 19 LAI Manipulated Variable for Variable Speed Drive % 20 LAI Current Type Fuel 0=Gas 21 LAI Current Output (Fire Rate) % 22 LAI Current Steam Pressure Setpoint psi bar 23 LAI Steam Pressure psi bar 24 LAI Flame Signal % 25 LAI Current Fuel Throughput 26 LAI Volume Unit of Gas 0=Cubic Meters 1=Cubic Feet 27 LAI Volume Unit of Oil 0=Liters 1=Gallons 28 LAI Unit of Temperature 0=Deg C 1=Deg F 29 LAI Unit of Pressure 0=bar 1=psi Page 6 of 10 Siemens Building Technologies, Inc.

Table 2. LMV51 Burner Controller for Steam Boilers Point Map, Application 4643. (continued) 30 LAI Sensor Selection 0=Pt100 1=Pt1000 2=Ni1000 3=Temperature Sensor 4=Pressure Sensor 5=Pt100Pt1000 6=Pt100Ni1000 7=No Sensor 31 LAI Startup Counter Total 32 LAI Hours Run Counter 33 LAI Current Error: Error Code 34 LAI Current Error: Diagnostic Code 35 LAI Current Error: Error Class 36 LAI Current Error: Error Phase See LMV51 and LMV52 Basic 37 LAI Temperature Limiter Off Threshold F 38 LAI Supply Air Temperature F 39 LDI Controller On/Off Off/On 40 LDI Fan Contactor Contact Off/On 41 LDI Fuel Selection Oil Off/On 42 LDI Fuel Selection Gas Off/On 44 LDI Maximum Oil Pressure Switch Off/On 45 LDI Minimum Oil Pressure Switch Off/On 46 LDI Pressure Valve Proving Off/On 47 LDI Safety Chain Off/On 49 LDI Maximum Gas Pressure Switch Off/On 50 LDI Minimum Gas Pressure Switch Off/On 52 LDI LP Off/On 53 LDI Start Release Oil Off/On 54 LDI Heavy Oil Immediate Start Off/On 55 LDI Alarm Off/On 59 LDI Ignition Off/On 60 LDI Start Signal/DW Valve Off/On 61 LDI Fan Off/On 62 LDI Oil Pump/Magnetic Coupling Off/On 63 LDI Fuel Valve SV Oil Off/On 64 LDI FuelValveV1Oil Off/On Siemens Building Technologies, Inc. Page 7 of 10

Table 2. LMV51 Burner Controller for Steam Boilers Point Map, Application 4643. (continued) 65 LDI FuelValveV2Oil Off/On 66 LDI FuelValveV3Oil Off/On 67 LDI Fuel Valve SV Gas Off/On 68 LDI FuelValveV1Gas Off/On 69 LDI FuelValveV2Gas Off/On 70 LDI Fuel Valve PV Gas Off/On 71 LAO Operating Mode with Load Controller 0=ExtLR X5-03 1=IntLR 2=IntL Bus 3=IntLR X62 4=ExtLR X62 5=ExtLR Bus 72 LAI Selection of Manual or Automatic Operation 0=Automatic 1=Burner On 2=Burner Off 73 LDO Modbus Mode Local/Remote 74 LAO Modbus Downtime: Maximum Time with No Communication. When This Time Has Elapsed, Automatic Changeover from Remote to Local Takes Place. 75 LAO Operating ModeinRemoteMode 0=Auto 1=Remote On 2=Remote Off 76 LAO External Setpoint W3 psi bar 77 LAO Predefined Output Modulation/Multistage 0 to 100.0%=Full Modulation 100.1%=Stage1 100.2%=Stage2 100.3%=Stage3 78 LAO Fuel Selection 0=Gas 79 LAO Setpoint W1 psi bar 80 LAO Setpoint W2 psi bar 81 LAO Weekday 0=Sunday 1=Monday 2=Tuesday 3=Wednesday 4=Thursday 5=Friday 6=Saturday 82 LAO Year yyyy 83 LAO Month mm 84 LAO Day dd sec Page 8 of 10 Siemens Building Technologies, Inc.

Table 2. LMV51 Burner Controller for Steam Boilers Point Map, Application 4643. (continued) 85 LAO Hour hr 86 LAO Minute min 87 LAO Second sec 89 LAO Hours Run Gas (Can Be Reset by Setting This 90 LAO Hours Run Oil Stage 1 or Modulating (Can Be Reset by Setting This 91 LAO Hours Run Oil Stage 2 or Modulating (Can Be Reset by Setting This 92 LAO Hours Run Oil Stage 3 or Modulating (Can Be Reset by Setting This 93 LAO Hours Run Total (Can Be Reset by Setting This 94 LAI Hours Run Total 96 LAI Hours Run Device Connected to Power (Read Only) 97 LAO Startup Counter Gas (Can Be Reset by Setting This 98 LAO Startup Counter Oil (Can Be Reset by Setting This 99 LAO Startup Counter Total (Can Be Reset by Setting This 100 LAI Startup Counter Total 101 LAI Fuel Volume Gas cu ft m 3 102 LAI Fuel Volume Oil gal L 103 LAI Number of Lockouts 104 LAI Lockout History (Current Lockout) Error Code 105 LAI Lockout History (Current Lockout) Error Diagnostics 106 LAI Lockout History (Current Lockout) Error Class 107 LAI Lockout History (Current Lockout) Error Phase See LMV51 and LMV52 Basic 108 LAI Lockout History (Current Lockout) Fuel 0=Gas 109 LAI Lockout History (Current Lockout) Output % 110 LAI Lockout History (Current Lockout) Date: Year yyyy 111 LAI Lockout History (Current Lockout) Date: Month mm 112 LAI Lockout History (Current Lockout) Date: Day dd 113 LAI Lockout History (Current Lockout) Time of Day: Hours hr 114 LAI Lockout History (Current Lockout) Time of Day: Minutes 115 LAI Lockout History (Current Lockout) Time of Day: Seconds 116 LAI Lockout History (Current Lockout) Startup Counter Total 117 LAI Lockout History (Current Lockout) Hours Run Total Siemens Building Technologies, Inc. Page 9 of 10

Table 2. LMV51 Burner Controller for Steam Boilers Point Map, Application 4643. (continued) 118 LAI Error History (Current Error) Error Code 119 LAI Error History (Current Error) Error Diagnosis 120 LAI Error History (Current Error) Error Class 121 LAI Error History (Current Error) Error Phase See LMV51 and LMV52 Basic 122 LAI Error History (Current Error) Error Fuel 123 LAI Error History (Current Error) Error Output 124 LAI Error History (Current Error) Error Startup Counter Total a Values noted for LDIs and LDOs are in the following format: OFF text/on text. b This column indicates the value/range or engineering units or both if known. c The default English value is not italicized. An italicized entry indicates an SI value. Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners. 2005 Siemens Building Technologies, Inc. Siemens Building Technologies, Inc. 1000 Deerfield Parkway Country of Origin: US Buffalo Grove, IL 60089-4513 Page10of10 U.S.A.