CERTIFICATE OF APPROVAL No CF 611

Similar documents
FIRE RESISTANCE OF A SLIDING ACCORDION DOOR ASSEMBLY. This report replaces FAR 3847 issued on the 2 April 2012

FIRE RESISTANCE OF A WONDOOR FIRE RATED CURTAIN WITH VARIATIONS TO CONSTRUCTION. P. Bano-Chapman Senior Fire Testing Engineer

CERTIFICATE OF FIRE APPROVAL

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

TaxAssist Cover Plus scheme Proposal acceptance form

PROPOSAL FOR JEWELERS BLOCK COVERAGE FORM

CERTIFICATE OF FIRE APPROVAL

Builder s Risk Renovation Application

QBE European Operations THB Freightshield Insurance Schedule

Future proofing New and Existing Buildings Flood Resilient Design and Construction Techniques

3M Mini D Ribbon (MDR) Connectors.050 Boardmount Through-Hole Rt. Angle Receptacle Shielded, SCSI-2 Layout 102 Series

Consulting Engineers. OfficePro Office and Professional Indemnity Insurance application for: Proposer Details. Part A

Design and Construct. OfficePro Office and Professional Indemnity Insurance application for: Proposer Details. Part A

The Society of Will Writers Proposal acceptance form

SAMPLE PROJECT IN LONDON DOCUMENT NO. STR-CALC UNITISED CURTAIN WALL 65 ENGINEER PROJECT. Pages REVISION TITLE

A context map Julie Bregulla. Offsite Construction_ _Julie Bregulla BRE

You can check your company details for free on our online service:

NIQ Ref: S&P/OF-164/NIQ/

Office insurance Proposal form

PRODUCT WARRANTY. 25 Year-Limited Mechanical & 5 Year-Limited Finish Warranty

ABS - AMERICAN BUILDING SUPPLY, INC. FALCON

Ontario Pharmacists Association

Infrastructure charge and miscellaneous services

2018 No ELECTRICITY GAS. The Electricity and Gas (Energy Company Obligation) Order 2018

Limited Liability Partnership Questionnaire

HARDWARE SCHEDULE PRAXIS3

Residential Unoccupied Property Owners Proposal Form

GENERAL CONDITIONS OF SALES and DELIVERY

Protocol of designing/constructing new insulated envelope buildings in respect of fire safety considerations

REQUEST FOR PROPOSAL Replace Detention Doors Rockingham County 05 NOVEMBER 2018

Access Fasteners Vic. Ph: (03) FAX: (03) W.A. Ph: (08) FAX (08)

Home Office. Proposal Form

AC Line Rated Ceramic Disc Capacitors Class X1, 400 V AC / Class Y4, 125 V AC

Quality scheme for wood treated with FR Build chemicals ( the Scheme ) SCHEME DOCUMENT

HOG CONFINEMENT QUESTIONNAIRE

ENVIRONMENT AGENCIES GUIDANCE ON SUITABILITY OF RADIOACTIVE WASTE ADVISERS

Price Guide SAFE LOCK A

Fundo Integro NEW. The slimmest standard-compliant complete wedi shower system.

Proposal for Jewelers Block Policy

Terms & Conditions of Sale

Home Insurance. A quick guide to your policy. Premier Select Cover

TECHNICAL REPORT. Testing of one sample described by the customer as 'Amtico Form IRE' to BS EN :2002.

Technical Services Report

AC Line Rated Ceramic Disc Capacitors Class X1, 760 V AC / Class Y1, 500 V AC

Insurance - A Guide to our Group Insurance Policy

FIRAS CERTIFICATION SCHEME

Proposal Form. Retailer. Commercial Division

CAS TRAINING COMPANY LIMITED Company Number: Incorporated on 1 September, 2005 in England/Wales REGISTER OF OFFICERS AT 15 MAY 2017 Quorum: 1

TENDER INVITATION Tender No. & Date Tender Opening Date & Time Project FF/3714/LPG/Cyls/Fongas/ CPO Dated 18 Oct 2018

Façade security standards Specifiers guide

CERTIFICATE OF FIRE APPROVAL

Frequently Asked Questions

205 CMR: MASSACHUSETTS GAMING COMMISSION 205 CMR : MONITORING OF PROJECT CONSTRUCTION AND LICENSEE REQUIREMENTS

Quality, Health & Safety and Environmental Information Pack

U.T. Administration of Dadra & Nagar Haveli Secretariat, Silvassa O R D E R

Hand outs for October 8, 2015, Insurance 101: Practical Considerations for Protecting Institutional Collections and Loans

Assessment Report. Report number: R A Page 1 of 13 ExTR number: GB/SIR/ExTR /00 Commercially in Confidence Form 9199 Issue 15

NATIONAL INSURANCE CONTRIBUTIONS BILL

S H A R E C A P I T A L

Self-directed support

Change of details of relevant legal entity (RLE) with significant control

Fire Protection Industry Scheme Reference SP205 Part 2

Contents Welcome Who provides your Audi MOT Cover? Policy summary Meaning of words Policy wording How to make a claim Important information

Public Cash Flow Statements

Building contract works questionnaire

PROBLEM SET B. The contribution margin per unit is $2.88, and the contribution margin ratio is 64%.

GRANDEUR PRODUCTS LIMITED

Commercial Combined. Please be aware that with effect from renewal The Underwriters for one or more Sections of this Policy have changed.

EXHIBIT 'A' SCOPE OF WORK

NHBC s guide to why buy this home

SPRI Roof System Listing Service Program

IPO Note. IPO Note SUBSCRIBE *** Company Overview:

Warmer Homes Scotland

Standards for Best Practices

VON DUPRIN ABS - AMERICAN BUILDING SUPPLY, INC. 22 SERIES EXIT DEVICES ALARM EXITS AND KITS TRIM FINISH ALUM DARK BRONZE

193. PROFILE ON THE PRODUCTION OF STEEL PROFILES

Laurel Hill Elementary

Building works questionnaire

Jewelers Block Application

Bordeaux Village One Condominium

TPAS AND THE FREEDOM OF INFORMATION ACT 2000

KOINONIA HOUSE (KHSE) CAMPUS PUBLIC SAFETY OFFICE (CPSO) RENOVATIONS Solicitation #1560

Quality, Health & Safety and Environmental Information Pack

NEWGEN. To, National Stock Exchange of India Limited. Bandra- Kurla Complex Mumbai Bandra (E), Mumbai

µmodule LGA Level 2 Interconnect Reliability Data

Thatched Home Quotation Request Form

166. PROFILE ON THE PRODUCTION OF DOOR LOCKS

RESERVE FUND STUDY. Hill & Associates Ltd. Member APEGNB July 2014

Type MPF, AC Motor Run Capacitors Oval and Round, Oil Filled, 70 ºC, Metallized Polypropylene Capacitors

General claims policy

Glass in School Buildings

Shops, Restaurants & Takeaways Proposal Form

Cig volumes surprise. Source: Company Data; PL Research

Swing-Out Ball Valves (SWB Series) Catalog 4125-SWB Revised, April 2004

2) No bid received may be withdrawn for a period of 30 days after the date of the bid opening.

Cyprus Companies Preliminary Instruction Questionnaire

SIMONSWERK North American Price List / /1.0

Management of Maintenance, Modification and Repair

Precious Metals News 6 th August 2011

Contractor Guide. (314)

Transcription:

CERTIFICATE OF APPROVAL No CF 611 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Stancliffe Street, Mill Hill, Blackburn BB2 2QR Tel: 01254 274100 Fax: 01254 274111 Have been assessed against the requirements of the Technical Schedule(s) denoted below and are approved for use subject to the conditions appended hereto: CERTIFIED PRODUCT TECHNICAL SCHEDULE TS23 The Contribution of Locks and Latches to the Performance of Fire Resisting of Doorsets Signed and sealed for and on behalf of CERTIFIRE Sir Ken Knight Chairman - Management Council Page 1 of 6

1. This approval applies only to the Eurospec locks and es detailed later in this certificate. 2. This certification is designed to demonstrate compliance of the product or system specifically with Approved Document B (England and Wales), Section D of the Technical Standards (Scotland) and Technical Booklet E (N. Ireland). If compliance is required to other regulatory or guidance documents there may be additional considerations or conflict to be taken into account. 3. This approval relates to their use with the following door assemblies: - Latched and uned, intumescent sealed door assemblies consisting of timber faced and edged leaves with timber, cellulosic or mineral cores in timber frames having a fire resistance up to 60 minutes (Code ITT). DLS and DLE ranges only - Latched and uned, insulated and uninsulated door assemblies consisting of metal faced and edged leaves in metal frames having a fire resistance up to 240 minutes (Code IMM/MM). 4. The locks and es are approved on the basis of: i) Initial type testing to EN12209 and BS EN 1634-1 ii) An appraisal against TS23 iii) Certification of quality management system to ISO 9001: 2008. iv) Inspection and surveillance of factory production control v) On-going audit testing in accordance with TS23 requirements 5. This approval is applicable only to the specified locks/es used with door assemblies of proven fire resistance (as defined in BS EN 1634-1 or BS 476: Part 22: 1987) and, when fitted to timber based doorsets, using appropriate intumescent protection. The required protection will be 2 mm thick Mono Ammonium Phosphate intumescent sheet behind the forend and strike/keep plates and around the lock case for all doorset assemblies. Failure to install the protection will invalidate this certificate. It is also required that 60 minute doorsets incorporate 4 mm thick, non-combustible, mineral based sub-facings. 6. Lock assemblies not incorporating a ing mechanism, or incorporating a rollerbolt ing mechanism, shall only be fitted to proven uned doorset assemblies. 7. The approval relates to on-going production. Product and/or its immediate packaging are identified with the manufacturer s name, the product name or number, the CERTIFIRE name or name and mark, together with the CERTIFIRE certificate number and application where appropriate. Page 2 of 6 Signed

8. The locks/es should not be fitted higher than 1100 mm from the finished floor level of the surrounding floors. 9. Timber doorsets shall be installed in accordance with BS 8214: 2008. 10. The following table shows acceptable doorset types and fire resistance periods: Approved Door Type Class IMM MM TT ITT ITM ITC FD20 FD30 FD60 FD120 FD240 E 20 EI 20 E 30 EI 30 E 60 EI 60 E 90 EI 90 E 120 EI 120 E 240 EI 240 See CERTIFIRE Technical Schedules for designation of doorset types i.e. ITT etc. * Only DLS and DLE lock ranges are approved for use with IMM/MM doorsets Page 3 of 6 Signed

Approved lock/ models and classifications. Lock/Latch Reference Description Classification to EN 12209: 2003 LSB5525 BS LSB5530 BS 2 H 8 1 0 F 7 K D 2 B LDB5525 BS LDB5530 BS 2 H 8 1 0 F 7 K D 0 B ESB5025 BS euro profile sashlock ESB5030 BS euro profile sashlock 2 H 8 1 0 F 7 B A 2 0 EDB5025 BS euro profile deadlock EDB5030 BS euro profile deadlock 2 H 8 1 0 F 7 B A 0 0 DLS7260 DIN sashlock 3 M 8 1 0 F 3 B A 2 0 DLS7260NL DIN night DLE7255NL DIN night DLE0055L DIN 3 M 8 1 0 F - B 0 2 0 DLES0060L DIN DLS0060EP DIN deadlock 3 M 8 1 0 F 3 B A 0 0 DLS7860WC DIN bathroom lock DLE7855WC DIN bathroom lock 3 M 8 1 0 F - B G 2 0 LSS5325 LSS5330 URLS5325 2 H 8 1 0 F 2 K D 2 A URLS5330 LSS5525 LSS5530 URLS5525 2 H 8 1 0 F 2 K D 2 B URLS5530 LDS5325 LDS5330 URLD5325 3 H 8 1 0 F 2 K D 0 A URLD5330 LDS5525 LDS5530 URLD5525 3 H 8 1 0 F 2 K D 0 B URLD5530 Page 4 of 6 Signed

Approved lock/ models and classifications. Lock/Latch Reference Description Classification to EN 12209: 2003 ESS5025 Euro profile sashlock ESS5030 Euro profile sashlock OSS5025 Oval profile sashlock 2 H 8 1 0 F 2 B A 2 0 OSS5030 Oval profile sashlock EDS5025 Euro profile deadlock EDS5030 Euro profile deadlock ODS5025 Oval profile deadlock 3 H 8 1 0 F 2 B A 0 0 ODS5030 Oval profile deadlock ULS5025 Upright ULS5030 Upright FLL5025 One way box 2 H 8 1 0 F - B 0 2 0 FLL5030 One way box BAS5025 BAS5030 URBS5025 2 H 8 1 0 F - B G 2 0 URBS5030 FLD8025 FLD8030 FLD8040 TLD5025 TLD5030 3 H 8 1 0 F - B G 0 0 TLD5040 TLD5825 TLD5830 TLD5840 DLE7255 EP Din sashlock 3 M 8 1 0 F 3 B C 2 0 DLE0055EP Din deadlock 3 M 8 1 0 F 3 B C 0 0 LSE5225 2 lever sashlock LSE5230 2 lever sashlock 2 H 8 1 0 F 1 K D 2 0 LSE5225REB 2 lever rebated sashlock LSE5325 LSE5330 2 H 8 1 0 F 1 K D 2 A LDE5325 LDE5330 2 H 8 1 0 F 1 K D 0 A BAE5025 BAE5030 2 H 8 1 0 F - B G 2 0 Page 5 of 6 Signed

Approved lock/ models and classifications. Lock/Latch Reference Description Classification to EN 12209: 2003 ULE5025 Upright ULE5030 Upright 2 H 8 1 0 F - B 0 2 0 RSE8053 Rim sashlock RSE8064 Rim sashlock 1 A 8 1 0 F NPD M D NPD 0 RLE8043 Rim NPD C 8 1 0 F - E 0 NPD 0 RDE8043 Rim deadlock 1 C 8 1 0 F NPD M D 0 0 TLS5025 TLS5030 TLS5040 NPD A 7 1 0 NPD - B 0 NPD 0 TLS5050 URES5025 Euro profile sashlock URES5030 Euro profile sashlock UROS5025 Oval profile sashlock 2 H 8 1 0 F 1 B A 2 0 UROS5030 Oval profile sashlock URED5025 Euro profile deadlock URED5030 Euro profile deadlock UROD5025 Oval profile deadlock 3 H 8 1 0 F 1 B A 0 0 UROD5030 Oval profile deadlock RSL5030 Rollerbolt deadbolt 3 C 8 1 0 F 2 B A 0 0 Further Information Further information regarding the details contained in this certificate may be obtained from Eurospec Architectural Hardware Limited (Tel: 01254 274100). Further information regarding CERTIFIRE certification and other approved products can be obtained from CERTIFIRE (Tel: 01925 646777). Page 6 of 6 Signed