Test Verification of Conformity 5F, No. 423, Ruiguang Road, Neihu District, Taipei 114, Taiwan Tel.: (+886-2) 6602 2888 Fax: (+886-2) 6602 2415 On the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the essential requirements of the referenced specifications at the time the tests were carried out. Applicant Name & Address : Edison Opto Corporation 4F, No. 800, Chung-Cheng Rd., Chung-Ho City, Taipei, Taiwan Product(s) Tested : PLCC Series Ratings and principal characteristics : Input: 5 Vdc, 60 ma Risk Group 1 (Low Risk) Model(s) : PLCC 5050 White Brand name : - Relevant Standard(s)/Specification(s) Verification Issuing Office Name & Address : EN 62471:2008 : 5F, No. 423, Ruiguang Road, Neihu District, Taipei 114, Taiwan Verification/Report Number(s) : TP10090230-ETS(R1) (TP10090230-ETS, TP10090230-ETS(R1)) NOTE 1: This verification is part of the full test report(s) and should be read in conjunction with it. This Verification is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Inertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to copy or distribute this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results referenced from this Verification are relevant only to the sample tested. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. October 4, 2011 www.intertek.com Page 1 of 1
TEST REPORT Page 1 of 7 Applicant: Edison Opto Corporation 4F, No. 800, Chung-Cheng Rd., Chung-Ho City, Taipei, Taiwan Product: PLCC Series Model: PLCC 5050 White Rating: 5 Vdc, 60 ma Sample Description: The submitted item is a PLCC Series LED for EN 62471: 2008 (Photobiological safety of lamps and lamp systems) Test. Photos of the samples are listed on the Appendix. Testing Requirement: Test for compliance with EN 62471:2008 Date of Receipt of Test: September 21, 2010 Date of Performance of Test: September 27, 2010 September 29, 2010 Conclusion: From the results of our testing on the submitted sample(s), we are of the opinion that the submitted sample(s) was classified as Risk Group 1 (Low-Risk) according to the above testing standard. Prepared by: Reviewed by: Dannel Hsu Project Engineer Timothy Young Senior Engineer
Note: Page 2 of 7 1) The testing results relate only to the items tested. 2) The test report shall not be reproduced except in full, without written approval of the laboratory. 3) This test report only allows to be revised within three years from its original issued date unless a further updating to the standard or requirement is noticed. 4) This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. 5) When determining the test conclusion, the Measurement Uncertainty of test has been considered.
Test Result: Page 3 of 7 Test Condition: Electrical Rating: 5 Vdc, 60 ma Measured Distance: 200 mm Test Results: 1. Angular subtense of apparent source. α = 9.27 mrad 2. Classification Emission Measurement Risk Action spectrum Symbol Units Exempt Group Risk Group 1 Limit Result Limit Result Actinic UV S UV (λ) E s W m -2 0,001 0.000030 0,003 N/A Near UV E UVA W m -2 10 0.000054 33 N/A Blue light B(λ) L B W m -2 sr -1 100 N/A 10000 N/A Blue light, small source B(λ) E B W m -2 1,0* --- 1,0 0.168286 (594.22 s) Retinal thermal R(λ) L R W m -2 sr -1 3020496 (28000/α) 11351.27 3020496 (28000/α) N/A Retinal thermal, weak visual stimulus** R(λ) L IR W m -2 sr -1 647249 (6000/α) N/A 647249 (6000/α) N/A IR radiation, eye E IR W m -2 100 0.117555 570 N/A * Small source defined as one with α < 0,011 radian. Averaging field of view at 10000 s is 0,1 radian. ** Involves evaluation of non-gls source Conclusion: Risk Group 1 (Low-Risk)
Appendix A: Page 4 of 7 Table of critical components and materials: Component Manufacturer/ trademark Type/model Value/rating Standard Approval/ reference SMD Type LED Edison Opto Corporation ET-5050W-3F1 W 5 Vdc, 60 ma Cool White EN 62471 Tested with appliance
Appendix B: Page 5 of 7 Wavelength
Appendix C: Page 6 of 7 Measurement of Beam Width